85224CY Datasheet
The Belden 85224CY is a four-conductor, 22 AWG bare copper XTRAGUARD FLEX continuous flex control cable with PVC insulation, a tinned copper braid shield, and an oil-resistant black PVC outer jacket. It is rated for a voltage of 600 V and operating temperatures ranging from -40°C to +90°C. This cable is designed for data, communication, audio, low-level signal transmission, industrial networking, and automation equipment.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
85224CY Key Specifications
- Nom. Capacitance Cond-to-Cond
- 31 pF/ft (100 pF/m)
- Nom. Capacitance Cond-to-Other
- 56 pF/ft (180 pF/m)
- Nom. Inductance
- 0.22 µH/ft (0.72 µH/m)
- Voltage Rating
- 600 V (AWM 2587 / CSA AWM)
- Operating temperature
- -40°C to +90°C
- Conductor configuration
- 4 conductors, 22 AWG (41x38 strand), Bare Copper (BC)
- Max pull tension
- 86 lbs (39 kg)
- Min. bend radius (stationary)
- 3.4 in (86 mm)
Characteristics (datasheet)
- Voltage Rating
- 600 V (AWM 2587 / CSA AWM)
- Conductor configuration
- 4 conductors, 22 AWG (41x38 strand), Bare Copper (BC)
- Shielding
- Tinned copper braid, 85% coverage
- Outer Jacket
- Black PVC, oil resistant, nominal thickness 0.035 in (0.89 mm)
- Nominal overall diameter
- 0.340 in (8.64 mm)
- Operating temperature
- -40°C to +90°C
- Nom. Capacitance Cond-to-Cond
- 31 pF/ft (100 pF/m)
- Nom. Capacitance Cond-to-Other
- 56 pF/ft (180 pF/m)
- Nom. Inductance
- 0.22 µH/ft (0.72 µH/m)
- Outer Shield DCR
- 34 Ohm/1000ft (110 Ohm/km)
- Min. bend radius (stationary)
- 3.4 in (86 mm)
- Max pull tension
- 86 lbs (39 kg)
85224CY Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 8729 — The Belden 8729 is a 4-conductor, 22 AWG tinned copper electronic cable with pol...
- 1817P — The Belden 1817P is a discontinued audio snake cable consisting of 8 pairs of 22...
- 9963 — The Belden 9963 is a 3-conductor electronic cable featuring 20AWG stranded tinne...
- 80048 — The Belden 80048 (ECOFLEX PUR) is an 18-conductor, 16 AWG tinned copper cable wi...
- 6225C — The Belden 6225C is a shielded communication and control cable consisting of fiv...
- 79215FLW — The 79215FLW is a Safe-T-Line shielded, fire-resistant multi-conductor cable des...
- 21661 — Belden 21661 is a 600 V Type TC/CIC power and control cable containing four stra...
- 1179C — The Belden 1179C is a communication and control cable featuring nine 22 AWG tinn...
More Bulk Wire Cable
- 1336A — The Belden 1336A is a 2-conductor 14 AWG tinned copper fieldbus cable with polyp...
- 1325A — The Belden 1325A is a plenum-rated (CMP), 2-pair, 22 AWG tinned copper cable wit...
- 8795 — The Belden 8795 is a 2-conductor 22 AWG solid bare copper communication cable fe...
- 5466C — The Belden 5466C is a shielded, 6-conductor 20 AWG tinned copper cable with PVC...
- 58804 — The Belden 58804 is a communication and control cable featuring 4 pairs of 24 AW...
- 80036 — The Belden 80036 (ECOFLEX PUR) is a 7-conductor, 18 AWG tinned copper cable with...
- 26320FL — Belden 26320FL is an armored plenum-rated fire alarm cable (FPLP) with two 18 AW...
- 77147 — The Belden 77147 is a 2-conductor, 26 AWG tinned copper ECOCABLE featuring mPPE...
85224CY FAQ
What is 85224CY?
85224CY is a Bulk Wire Cable from Belden. The Belden 85224CY is a four-conductor, 22 AWG bare copper XTRAGUARD FLEX continuous flex control cable with PVC insulation, a tinned copper braid shield, and an oil-resistant black PVC outer jacket. It is rated for a voltage of 600 V and operating temperatures ranging from -40°C to +90°C. This cable is designed for data, communication, audio, low-level signal transmission, industrial networking, and automation equipment.
Who manufactures 85224CY?
85224CY is manufactured by Belden.
Where can I download the 85224CY datasheet PDF?
The 85224CY datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 85224CY specifications
Click to ask a quick question:
Parameters
| Conductor configuration | 4 conductors, 22 AWG (41x38 strand), Bare Copper (BC) |
| Max pull tension | 86 lbs (39 kg) |
| Min. bend radius (stationary) | 3.4 in (86 mm) |
| Nom. Capacitance Cond-to-Cond | 31 pF/ft (100 pF/m) |
| Nom. Capacitance Cond-to-Other | 56 pF/ft (180 pF/m) |
| Nominal overall diameter | 0.340 in (8.64 mm) |
| Nom. Inductance | 0.22 µH/ft (0.72 µH/m) |
| Operating temperature | -40°C to +90°C |
| Outer Jacket | Black PVC, oil resistant, nominal thickness 0.035 in (0.89 mm) |
| Outer Shield DCR | 34 Ohm/1000ft (110 Ohm/km) |
| Shielding | Tinned copper braid, 85% coverage |
| Voltage Rating | 600 V (AWM 2587 / CSA AWM) |