The Belden 8875MN is a SpaceMaker™ shielded cable consisting of two 18 AWG tinned copper pairs with polypropylene insulation, individual and overall Beldfoil shields, and a PVC outer jacket. It is designed for transmitting low voltage analog and digital signals, line level audio, and computer communication, as well as for panel wiring. The cable operates within a temperature range of -20°C to +80°C, supports a maximum conductor current of 11.2 Amps at 30°C, and has a nominal characteristic impedance of 39 Ohm.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

8875MN Key Specifications

Max. Current
11.2 Amps per Conductor at 30ºC
UL Voltage Rating
300 V
Operating Temperature
-20°C to +80°C
Conductor
2 pairs, 18 AWG 41x34 TC - Tinned Copper
Max. Pull Tension
121.7 lbs (55.20 kg)
Nom. Characteristic Impedence
39 Ohm
Nom. Conductor DCR
7.06 Ohm/1000ft
Overall Cable Diameter (Nominal)
0.290 in (7.37 mm)

Characteristics (datasheet)

Conductor
2 pairs, 18 AWG 41x34 TC - Tinned Copper
UL Voltage Rating
300 V
Max. Current
11.2 Amps per Conductor at 30ºC
Operating Temperature
-20°C to +80°C
Nom. Characteristic Impedence
39 Ohm
Nom. Conductor DCR
7.06 Ohm/1000ft
Overall Cable Diameter (Nominal)
0.290 in (7.37 mm)
Max. Pull Tension
121.7 lbs (55.20 kg)

8875MN Applications

  • low voltage analog signals (4-20ma, 0-10v, ...)
  • low voltage digital control (24v, …)
  • line level audio
  • computer communication
  • panel wiring

Other Belden parts

  • 79227 — The Belden 79227 is a 4-conductor 14 AWG tinned copper cable with mPPE insulatio...
  • 1333A — The Belden 1333A is a high-performance 24-pair 18AWG tinned copper fieldbus cabl...
  • 1886ELV — The 1886ELV is a Category 7A enhanced premise horizontal cable with 4 pairs of 2...
  • 6060 — The Belden 6060 is a Teck90 600V heavy-duty cable designed for CEC power and con...
  • 2128A — The Belden 2128A is a heavy-duty fieldbus cable designed for harsh environment d...
  • 76714TS — The Belden 76714TS is a high-flex multi-conductor cable from the MachFlex™ serie...
  • 25103 — Belden 25103 is an XTRAGUARD 2 cable with 3 conductors of 22 AWG (7/30) tinned c...
  • 25122 — Belden part 25122 is an XTRAGUARD 2 cable consisting of 2 pairs of 22 AWG (7x30)...

More Bulk Wire Cable

  • 2139A — The Belden 2139A is a discontinued Category 5e premise backbone cable designed f...
  • 3210 — The Belden 3210 is a single-conductor communication and control cable featuring...
  • 88442 — The Belden 88442 is a high-temperature, plenum-rated (CMP) electronic cable feat...
  • 78073 — The Belden 78073 is a 3-pair, 24 AWG tinned copper communication cable with modi...
  • 3049 — The Belden 3049 is a single-conductor hook-up wire constructed of 26 AWG strande...
  • 55292 — The Belden 55292 is an XTRAGUARD 5 shielded cable featuring two 20 AWG tinned co...
  • 6831 — The Belden 6831 is a single-conductor 10 AWG hook-up wire with bare copper condu...
  • 5680 — The Belden 5680 is a 10-conductor, 26 AWG tinned copper cable with semi-rigid PV...

8875MN FAQ

What is 8875MN?

8875MN is a Bulk Wire Cable from Belden. The Belden 8875MN is a SpaceMaker™ shielded cable consisting of two 18 AWG tinned copper pairs with polypropylene insulation, individual and overall Beldfoil shields, and a PVC outer jacket. It is designed for transmitting low voltage analog and digital signals, line level audio, and computer communication, as well as for panel wiring. The cable operates within a temperature range of -20°C to +80°C, supports a maximum conductor current of 11.2 Amps at 30°C, and has a nominal characteristic impedance of 39 Ohm.

Who manufactures 8875MN?

8875MN is manufactured by Belden.

Where can I download the 8875MN datasheet PDF?

The 8875MN datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 8875MN specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor2 pairs, 18 AWG 41x34 TC - Tinned Copper
Max. Current11.2 Amps per Conductor at 30ºC
Max. Pull Tension121.7 lbs (55.20 kg)
Nom. Characteristic Impedence39 Ohm
Nom. Conductor DCR7.06 Ohm/1000ft
Operating Temperature-20°C to +80°C
Overall Cable Diameter (Nominal)0.290 in (7.37 mm)
UL Voltage Rating300 V