28628A Datasheet
Belden 28628A is a 50-conductor, 16 AWG (7x24 bare copper) UL Type TC power and control cable with PVC/nylon conductor insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90°C dry and wet, and is suitable for indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial installations, including Class 1 Division 2 hazardous locations. The unshielded cable has a nominal overall diameter of 0.990 in, includes a ripcord, and has a maximum pull tension of 1785 lbs.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
28628A Key Specifications
- Max. Current
- 6.3 Amps per Conductor at 30ºC
- UL Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature
- 90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C To +90°C
- Conductor
- 50 conductors, 16 AWG, 7x24 stranding, BC - Bare Copper
- Insulation
- PVC/Nylon - Polyvinyl Chloride + Nylon, 0.022 in (0.56 mm) nominal thickness
- Jacket
- PVC - Polyvinyl Chloride, 0.083 in (2.1 mm) nominal thickness
- Max. Pull Tension
- 1785 lbs (809.7 kg)
- Nom. Conductor DCR
- 4.2 Ohm/1000ft
Characteristics (datasheet)
- Conductor
- 50 conductors, 16 AWG, 7x24 stranding, BC - Bare Copper
- Insulation
- PVC/Nylon - Polyvinyl Chloride + Nylon, 0.022 in (0.56 mm) nominal thickness
- Jacket
- PVC - Polyvinyl Chloride, 0.083 in (2.1 mm) nominal thickness
- UL Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature
- 90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C To +90°C
- Nom. Conductor DCR
- 4.2 Ohm/1000ft
- Max. Current
- 6.3 Amps per Conductor at 30ºC
- Max. Pull Tension
- 1785 lbs (809.7 kg)
28628A Applications
- Power and Control Applications up to 600V
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 23532D — Belden part 23532D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V wit...
- 80163 — The Belden 80163 is a heavy-duty, 3-conductor 10 AWG tinned copper cable with mP...
- 6608HS — The 6608HS is a discontinued analog audio cable from Gepco (a Belden brand) desi...
- 45120 — Belden part 45120 is an XTRAGUARD 4 cable containing 10 conductors of 24 AWG (7x...
- 78003 — The Belden 78003 is a multi-conductor cable featuring three 28 AWG tinned copper...
- 6053 — The Belden 6053 is a Teck90 600V heavy-duty cable featuring four 12 AWG bare cop...
- 89182 — The Belden 89182 is a 150Ω twinaxial cable featuring a single pair of 22 AWG tin...
- 1590 — The Belden 1590 is a heavy-duty TW-75 600V bulk cable featuring a single 1 AWG 1...
More Bulk Wire Cable
- 80159 — The Belden 80159 ECOFLEX PUR cable is a 4-conductor, 12 AWG tinned copper cable...
- 80134 — The Belden 80134 is a 4-conductor, 18 AWG tinned copper cable with mPPE insulati...
- 3430 — The Belden 3430 is a 30-conductor, 18 AWG tinned copper communication and contro...
- 5033C — The Belden 5033C is an XTRAGUARD 1 cable with three 18 AWG tinned copper pairs,...
- 5309UE — The Belden 5309UE is a riser-CMR security and sound cable featuring 12 stranded...
- 8105 — The Belden 8105 is a computer EIA RS-232/422 cable consisting of 5 twisted pairs...
- 1505A — The Belden 1505A is a 75 Ohm SDI coaxial cable of RG-59 type, built with a 20 AW...
- 7415W — The 7415W is a MachFlex™ high-flexibility cable featuring 11 conductors plus 1 g...
28628A FAQ
What is 28628A?
28628A is a Bulk Wire Cable from Belden. Belden 28628A is a 50-conductor, 16 AWG (7x24 bare copper) UL Type TC power and control cable with PVC/nylon conductor insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90°C dry and wet, and is suitable for indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial installations, including Class 1 Division 2 hazardous locations. The unshielded cable has a nominal overall diameter of 0.990 in, includes a ripcord, and has a maximum pull tension of 1785 lbs.
Who manufactures 28628A?
28628A is manufactured by Belden.
Where can I download the 28628A datasheet PDF?
The 28628A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 28628A specifications
Click to ask a quick question:
Parameters
| Conductor | 50 conductors, 16 AWG, 7x24 stranding, BC - Bare Copper |
| Insulation | PVC/Nylon - Polyvinyl Chloride + Nylon, 0.022 in (0.56 mm) nominal thickness |
| Jacket | PVC - Polyvinyl Chloride, 0.083 in (2.1 mm) nominal thickness |
| Max. Current | 6.3 Amps per Conductor at 30ºC |
| Max. Pull Tension | 1785 lbs (809.7 kg) |
| Nom. Conductor DCR | 4.2 Ohm/1000ft |
| Temperature | 90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C To +90°C |
| UL Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |