5400FE
The Belden 5400FE is a security and commercial audio cable with a riser-CMR rating, designed with two 20 AWG stranded bare copper conductors insulated in polypropylene, a Beldfoil shield, and a PVC jacket with a ripcord. It is suitable for intercom/PA systems and sound/audio systems, rated for a UL voltage of 300 V with an operating temperature range of -20°C to +75°C.
5373C
The Belden 5373C is a shielded, 3-pair, 18 AWG tinned copper cable with PVC insulation and a slate PVC outer jacket, rated for 300 V and operating temperatures from -30°C to +105°C. It features an overall aluminum/polyester shield and a nominal diameter of 0.352 in (8.94 mm). This XTRAGUARD 1 cable is designed for industrial control systems, instrumentation and control circuits, and PLC and DCS systems.
5350C
The Belden 5350C is a 5-pair, 20 AWG tinned copper conductor shielded cable with semi-rigid PVC insulation and a slate PVC outer jacket, rated for 300 V and operating temperatures from -35°C to +105°C. It is designed for industrial control systems, raceways, cable trays, and ducts, as well as instrumentation and control circuits carrying analog and digital signals. Typical applications include PLC and DCS systems, sensors, encoders, solenoids, valves, actuators, and positioners in indoor and outdoor sunlight-resistant environments.
5329UL
The Belden 5329UL is a riser-grade (FPLR) indoor fire alarm cable featuring 12 solid bare copper conductors of 18 AWG size with polypropylene insulation and a PVC outer jacket with a ripcord. It is designed for use in fire alarm, monitor/detection, and audio, control, initiating, and notification circuits. The cable is rated for a UL voltage of 300 V, a maximum current of 3.5 Amps per conductor, and an operating temperature range of -20°C to +75°C.
5282C
The Belden 5282C is a 2-pair, 20 AWG tinned copper cable with PVC insulation and a slate PVC outer jacket, rated for 300 V and operating temperatures from -30°C to +105°C. It is designed for use in industrial control systems, instrumentation, and PLC/DCS applications, supporting analog and digital signals. The cable features excellent flame retardancy (FT4, VW-1), sunlight resistance, and is suitable for indoor and outdoor use in raceways and cable trays.
5201C
The Belden 5201C is a 7-conductor, 24 AWG tinned copper cable with semi-rigid PVC insulation and a slate PVC outer jacket, rated for 300 V and an operating temperature range of -35°C to +105°C. It is designed for industrial control systems, raceways, cable trays, and ducts, as well as instrumentation and control circuits, supporting analog and digital signals for PLC and DCS systems, sensors, encoders, solenoids, valves, actuators, and positioners.
5178C
The 5178C is an XTRAGUARD 1 shielded cable featuring eight 16 AWG stranded tinned copper conductors with PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V with an operating temperature range of -30°C to +105°C, carrying multiple compliance approvals such as CM 105C, AWM/STYLE 2464, and AWM/STYLE 2517. This cable is designed for industrial control systems, instrumentation and control circuits, analog and digital signals, and PLC and DCS systems.
5120C
The 5120C is a 10-conductor, 24 AWG tinned copper shielded cable with semi-rigid PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures from -35°C to +105°C. It provides sunlight resistance and is suitable for both indoor and outdoor environments. This cable is designed for use in industrial control systems, instrumentation and control circuits, and PLC and DCS systems.
5103C
The Belden 5103C is a 3-conductor, 22 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and operating temperatures from -35°C to +105°C, with flame-retardant and sunlight-resistant properties. This shielded cable is designed for industrial control systems, instrumentation and control circuits, and PLC and DCS systems, carrying analog and digital signals to sensors, solenoids, valves, and actuators.
5102C
The Belden 5102C is a shielded, two-conductor 22 AWG tinned copper cable with semi-rigid PVC insulation and a slate PVC outer jacket. It is rated for a voltage of 300 V and supports an operating temperature range of -35°C to +105°C. The cable is designed for use in industrial control systems, instrumentation, and analog/digital signal transmission.
5096C
The Belden 5096C is a shielded, multi-conductor cable featuring 6 conductors of 24 AWG stranded tinned copper with semi-rigid PVC insulation and a slate PVC outer jacket. It is rated for a voltage of 300 V and supports operating temperatures between -35 °C and +105 °C. This cable is designed for use in industrial control systems, instrumentation, analog and digital signal transmission, and PLC/DCS systems.
5093C
The Belden 5093C (XTRAGUARD 1) is a 3-conductor, 24 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V with an operating temperature range of -35°C to +105°C. This shielded cable is designed for industrial control systems, instrumentation and control circuits, analog and digital signals, and PLC and DCS systems, connecting sensors, solenoids, valves, actuators, and positioners in raceways, cable trays, and ducts.
5070C
The Belden 5070C is a 10-conductor, 18 AWG tinned copper cable with PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures up to 105°C. It is designed for use in industrial control systems, instrumentation and control circuits, and analog and digital signal applications, such as sensors, valves, and actuators. It features sunlight resistance, oil resistance, and flame ratings including FT4 and VW-1, suitable for indoor and outdoor environments.
5068C
The Belden 5068C is an XTRAGUARD 1 multi-conductor cable featuring 8 stranded tinned copper conductors with PVC insulation and a slate PVC outer jacket. It is rated for a voltage of 300 V and supports operating temperatures between -30°C and +105°C. This cable is designed for use in industrial control systems, raceways, cable trays, ducts, instrumentation, and control circuits, carrying analog and digital signals for PLCs, DCS, sensors, valves, and actuators.
5690
The Belden 5690 is a 2-pair, 26 AWG tinned copper cable with semi-rigid PVC insulation, an overall bi-laminate aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300V with an operating temperature range of -35°C to +105°C. This shielded cable is designed for data, communication, audio, low-level signal transmission, industrial networking, control panels, automation equipment, and instrumentation systems.
5669
The Belden 5669 is a 6-conductor, 26 AWG tinned copper cable with semi-rigid PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures between -35°C and +105°C. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, automation, and instrumentation systems. The cable meets multiple UL, CSA, and international flammability and environmental compliance standards, including FT4, CMG, VW-1, and RoHS.
5492C
The Belden 5492C is a XTRAGUARD 1 shielded multi-conductor cable featuring 2 pairs of 24 AWG tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for a voltage of 300 V and operates within a temperature range of -35°C to +105°C. This cable is designed for use in industrial control systems, instrumentation and control circuits, analog and digital signals, and PLC and DCS systems.
5447
The Belden 5447 is a 7-conductor, 14 AWG tinned copper cable with PVC insulation and a slate PVC outer jacket. It is rated for a voltage of 600 V and supports operating temperatures between -30°C and +105°C. This cable is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, and automation equipment.
5413
The Belden 5413 is an XTRAGUARD 1 multi-conductor cable featuring three 20 AWG stranded tinned copper conductors with PVC insulation and a slate PVC outer jacket. It is rated for 600 V and operates within a temperature range of -30°C to +105°C. This cable is designed for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
5404
The Belden 5404 is a 4-conductor, 22 AWG tinned copper control cable with PVC insulation and a slate PVC outer jacket, rated for a voltage of 600 V and operating temperatures from -30°C to +105°C. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, automation equipment, and instrumentation systems. The cable has a nominal diameter of 0.358 in (9.09 mm) and complies with various industry standards including AWM, MTW, CSA, and FT4 flammability ratings.