5693 Datasheet
The Belden 5693 is a shielded, multi-conductor cable containing five 26 AWG tinned copper pairs with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, control panels, automation equipment, and instrumentation systems. The cable is rated for a voltage of 300 V and operates within a temperature range of -35°C to +105°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
5693 Key Specifications
- Nom. Capacitance Cond-to-Cond
- 22.4 pF/ft (73.5 pF/m)
- UL Voltage Rating
- 300 V (CM, CMG, AWM 2464, AWM 2517)
- Operating Temperature
- -35°C to +105°C (UL Temperature: 105°C)
- Conductor
- 5 pairs, 26 AWG 7x34 TC - Tinned Copper
- Minimum Bend Radius (Stationary)
- 2.5 in (64 mm)
- Nominal Cable Diameter
- 0.246 in (6.25 mm)
- Nominal Characteristic Impedance
- 84 Ohm
- Nom Outer Shield DCR
- 208 Ohm/1000ft (682 Ohm/km)
Characteristics (datasheet)
- Conductor
- 5 pairs, 26 AWG 7x34 TC - Tinned Copper
- Nominal Cable Diameter
- 0.246 in (6.25 mm)
- UL Voltage Rating
- 300 V (CM, CMG, AWM 2464, AWM 2517)
- Operating Temperature
- -35°C to +105°C (UL Temperature: 105°C)
- Nominal Characteristic Impedance
- 84 Ohm
- Nom. Capacitance Cond-to-Cond
- 22.4 pF/ft (73.5 pF/m)
- Nom Outer Shield DCR
- 208 Ohm/1000ft (682 Ohm/km)
- Minimum Bend Radius (Stationary)
- 2.5 in (64 mm)
5693 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 3498C — The Belden 3498C is an 8-pair, 28 AWG tinned copper communication and control ca...
- 30830 — Belden 30830 is a 3/0 AWG (630x26) tinned copper lead wire with silicone rubber...
- 1390 — The Belden 1390 is a 1000V RWU90 power and control cable featuring 3 AWG strande...
- 79110 — The Belden 79110 (Alpha Wire P/N 79110) is a 3-conductor, 18 AWG tinned copper c...
- 6075 — The Belden 6075 is a Teck90 600V cable designed for CEC power and control applic...
- 5523 — The Belden 5523 is a shielded 3-conductor, 18 AWG stranded tinned copper cable w...
- 79016 — The Belden 79016 ECOFLEX is a highly flexible, 12-conductor, 18 AWG tinned coppe...
- 1363A — The Belden 1363A is an 8-pair, 16 AWG tinned copper fieldbus cable with polyprop...
More Bulk Wire Cable
- 70010PU — The 70010PU is a PROFINET Type R high-flexibility cable featuring 4 conductors m...
- 8445 — The Belden 8445 is a 5-conductor electronic cable constructed with 22 AWG tinned...
- 21668 — Belden part 21668 is a CSA TC-CIC 600 V tray cable with two 1/0 AWG stranded bar...
- 30820 — The Belden 30820 is a 20 AWG (10x30) stranded tinned copper lead wire with silic...
- 8453 — The Belden 8453 is a portable cordage cable featuring three 18 AWG stranded tinn...
- 8700 — The Belden 8700 is a miniature, 28 AWG solid tinned copper coaxial cable designe...
- 3078F — The Belden 3078F is a flexible high-speed fieldbus cable featuring a single 22 A...
- 80036 — The Belden 80036 (ECOFLEX PUR) is a 7-conductor, 18 AWG tinned copper cable with...
5693 FAQ
What is 5693?
5693 is a Bulk Wire Cable from Belden. The Belden 5693 is a shielded, multi-conductor cable containing five 26 AWG tinned copper pairs with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, control panels, automation equipment, and instrumentation systems. The cable is rated for a voltage of 300 V and operates within a temperature range of -35°C to +105°C.
Who manufactures 5693?
5693 is manufactured by Belden.
Where can I download the 5693 datasheet PDF?
The 5693 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 5693 specifications
Click to ask a quick question:
Parameters
| Conductor | 5 pairs, 26 AWG 7x34 TC - Tinned Copper |
| Minimum Bend Radius (Stationary) | 2.5 in (64 mm) |
| Nom. Capacitance Cond-to-Cond | 22.4 pF/ft (73.5 pF/m) |
| Nominal Cable Diameter | 0.246 in (6.25 mm) |
| Nominal Characteristic Impedance | 84 Ohm |
| Nom Outer Shield DCR | 208 Ohm/1000ft (682 Ohm/km) |
| Operating Temperature | -35°C to +105°C (UL Temperature: 105°C) |
| UL Voltage Rating | 300 V (CM, CMG, AWM 2464, AWM 2517) |