1363A Datasheet
The Belden 1363A is an 8-pair, 16 AWG tinned copper fieldbus cable with polypropylene insulation, dual Beldfoil shields, and a PVC outer jacket. It is designed for harsh environment digital and serial two-way communication, particularly in oil and gas extraction, petrochemical sites, and process automation applications like Profibus or Foundation FieldBus. It supports extreme temperature environments and long-distance remote applications.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1363A Key Specifications
- Max. Current
- 5.2 Amps per Conductor
- Nom. Capacitance Cond-to-Shield
- 45 pF/ft (150 pF/m)
- UL Voltage Rating
- 300 V RMS
- Operating temperature
- -40°C to +105°C
- Bulk cable weight
- 360 lbs/1000ft (540 kg/km)
- Characteristic impedance
- 100 Ohm
- Conductor configuration
- 8 pairs, 16 AWG, 7x24 stranded TC - Tinned Copper
- Max. Pull Tension
- 571 lbs (259 kg)
Characteristics (datasheet)
- Conductor configuration
- 8 pairs, 16 AWG, 7x24 stranded TC - Tinned Copper
- Characteristic impedance
- 100 Ohm
- Nom. Conductor DCR
- 4.2 Ohm/1000ft (14 Ohm/km)
- Nom. Capacitance Cond-to-Shield
- 45 pF/ft (150 pF/m)
- UL Voltage Rating
- 300 V RMS
- Max. Current
- 5.2 Amps per Conductor
- Operating temperature
- -40°C to +105°C
- Outer jacket nominal diameter
- 0.914 in
- Bulk cable weight
- 360 lbs/1000ft (540 kg/km)
- Max. Pull Tension
- 571 lbs (259 kg)
1363A Applications
- Harsh environment digital and serial two-way communication
- Oil and gas extraction and refining sites
- Petrochemical
- Profibus process automation or Foundation FieldBus process automation
- Extreme temperature environments
- Exposure to humidity/moisture, dust, and oil
- Remote locations long distance applications
Other Belden parts
- 5672 — The Belden 5672 is an XTRAGUARD 1 multi-conductor cable featuring 10 conductors...
- 35110 — The Belden 35110 is an XTRAGUARD 3 multi-conductor cable with 10 conductors of 2...
- 5478C — The Belden 5478C is an 8-pair, 24 AWG tinned copper conductor communication and...
- 9520 — The Belden 9520 is a high-performance instrumentation cable consisting of 9 pair...
- 28086A — Belden 28086A is an 8-conductor, 14 AWG (7x22 bare copper) power and control cab...
- 7710A — The Belden 7710A is a VideoFLEX Digital Coax Snake Cable with a riser-CMR rating...
- 25511D — The Belden 25511D is a Canadian TC-ACIC instrumentation cable rated for 600 V, b...
- 80118 — The Belden 80118 (ECOFLEX PUR) is a highly flexible, shielded 9-conductor cable...
More Bulk Wire Cable
- 2003C — The Belden 2003C is a 2-conductor 18 AWG tinned copper electronic cable featurin...
- 2183P — The Belden 2183P is a plenum-rated (CMP-LP) 4-pair 23 AWG solid bare copper F/UT...
- 3107A — The Belden 3107A is a dual-pair 22 AWG tinned copper RS-485 cable with polyethyl...
- 6501FE — The 6501FE is a plenum-rated security and sound cable featuring three 22 AWG str...
- 1351A — The Belden 1351A is a discontinued Category 6 premise horizontal cable (250 MHz)...
- 21633 — The Belden 21633 is a CSA TC-CIC 600 V tray cable containing 35 conductors of 10...
- 1326A — The Belden 1326A is a discontinued plenum-rated (CMP) security and commercial au...
- 43907NH — The Belden 43907NH is a discontinued 8-conductor speaker cable with 2.5 mm² oxyg...
1363A FAQ
What is 1363A?
1363A is a Bulk Wire Cable from Belden. The Belden 1363A is an 8-pair, 16 AWG tinned copper fieldbus cable with polypropylene insulation, dual Beldfoil shields, and a PVC outer jacket. It is designed for harsh environment digital and serial two-way communication, particularly in oil and gas extraction, petrochemical sites, and process automation applications like Profibus or Foundation FieldBus. It supports extreme temperature environments and long-distance remote applications.
Who manufactures 1363A?
1363A is manufactured by Belden.
Where can I download the 1363A datasheet PDF?
The 1363A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1363A specifications
Click to ask a quick question:
Parameters
| Bulk cable weight | 360 lbs/1000ft (540 kg/km) |
| Characteristic impedance | 100 Ohm |
| Conductor configuration | 8 pairs, 16 AWG, 7x24 stranded TC - Tinned Copper |
| Max. Current | 5.2 Amps per Conductor |
| Max. Pull Tension | 571 lbs (259 kg) |
| Nom. Capacitance Cond-to-Shield | 45 pF/ft (150 pF/m) |
| Nom. Conductor DCR | 4.2 Ohm/1000ft (14 Ohm/km) |
| Operating temperature | -40°C to +105°C |
| Outer jacket nominal diameter | 0.914 in |
| UL Voltage Rating | 300 V RMS |