82418 Datasheet
The Belden 82418 is a 4-conductor, 18 AWG tinned copper electronic cable with FEP insulation, an overall Beldfoil shield, and a PVC outer jacket. It is designed for indoor plenum applications and is suitable for low-voltage analog signals, low-voltage control, line level audio, voice communications, and panel wiring. The cable is rated for a UL voltage of 300 V (CMP) and supports a maximum current of 4.3 Amps per conductor at 25°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
82418 Key Specifications
- Max. Current
- 4.3 Amps per Conductor at 25ºC
- Nom. Capacitance Cond-to-Cond
- 30 pF/ft (98 pF/m)
- UL Voltage Rating
- 300 V (CMP)
- Operating Temperature
- -20°C to +75°C
- UL Temperature
- 60°C
- Conductor
- 4 x 18 AWG (19x30) Tinned Copper
- Insulation Material
- FEP - Fluorinated Ethylene Propylene
- Max. Pull Tension
- 114 lbs (51.7 kg)
Characteristics (datasheet)
- Conductor
- 4 x 18 AWG (19x30) Tinned Copper
- Insulation Material
- FEP - Fluorinated Ethylene Propylene
- Outer Shield
- Bi-Laminate (Alum+Poly) Tape, 100% coverage, 20 AWG (19x32) TC drainwire
- Outer Jacket Material
- PVC - Polyvinyl Chloride
- Nominal Outer Diameter
- 0.172 in (4.37 mm)
- Nom. Conductor DCR
- 6.92 Ohm/1000ft
- Nom. Capacitance Cond-to-Cond
- 30 pF/ft (98 pF/m)
- Operating Temperature
- -20°C to +75°C
Absolute Maximum Ratings
- UL Voltage Rating
- 300 V (CMP)
- Max. Current
- 4.3 Amps per Conductor at 25ºC
- UL Temperature
- 60°C
- Max. Pull Tension
- 114 lbs (51.7 kg)
82418 Applications
- indoor plenum applications
- low voltage analog signals (4-20ma, 0-10v, ...)
- low voltage control (24v, …)
- line level audio
- voice communications
- panel wiring
Other Belden parts
- 9526 — The Belden 9526 is a high-performance instrumentation cable containing 19 pairs...
- 5859 — The Belden 5859 is a single-conductor 14 AWG hook-up wire featuring silver-plate...
- 1523A — The Belden 1523A is a broadband coaxial cable belonging to Series 11, featuring...
- 9192 — The Belden 9192 is a discontinued video triaxial cable of RG11 type, featuring a...
- 5475C — The Belden 5475C is a multi-pair communication and control cable consisting of 5...
- 1083A — The Belden 1083A is an UL-rated instrumentation cable featuring four 20 AWG tria...
- 80127 — The Belden 80127 (Alpha Wire P/N 80127) is an 18-conductor, 20 AWG tinned copper...
- 83047 — The Belden 83047 is a high-temperature plastic lead wire featuring a 24 AWG silv...
More Bulk Wire Cable
- 8012 — The Belden 8012 is a bus bar wire featuring a 14 AWG solid tinned copper conduct...
- 78445 — The Belden 78445 is a 25-conductor 20 AWG tinned copper ECOCABLE designed for da...
- 1468A — The Belden 1468A is an UL-listed instrumentation and control cable featuring 12...
- 23508D — The Belden 23508D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, con...
- 1047A — The Belden 1047A is a 50-pair UL instrumentation cable featuring 16 AWG bare cop...
- 9058 — The Belden 9058 is an RG6 CATV video coaxial cable featuring an 18 AWG solid bar...
- 1087A — The Belden 1087A is a 36-pair, 18 AWG bare copper instrumentation cable featurin...
- 45162 — Belden part 45162 is a 2-conductor 18 AWG (16x30 stranded tinned copper) XTRAGUA...
82418 FAQ
What is 82418?
82418 is a Bulk Wire Cable from Belden. The Belden 82418 is a 4-conductor, 18 AWG tinned copper electronic cable with FEP insulation, an overall Beldfoil shield, and a PVC outer jacket. It is designed for indoor plenum applications and is suitable for low-voltage analog signals, low-voltage control, line level audio, voice communications, and panel wiring. The cable is rated for a UL voltage of 300 V (CMP) and supports a maximum current of 4.3 Amps per conductor at 25°C.
Who manufactures 82418?
82418 is manufactured by Belden.
Where can I download the 82418 datasheet PDF?
The 82418 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 82418 specifications
Click to ask a quick question:
Parameters
| Conductor | 4 x 18 AWG (19x30) Tinned Copper |
| Insulation Material | FEP - Fluorinated Ethylene Propylene |
| Max. Current | 4.3 Amps per Conductor at 25ºC |
| Max. Pull Tension | 114 lbs (51.7 kg) |
| Nom. Capacitance Cond-to-Cond | 30 pF/ft (98 pF/m) |
| Nom. Conductor DCR | 6.92 Ohm/1000ft |
| Nominal Outer Diameter | 0.172 in (4.37 mm) |
| Operating Temperature | -20°C to +75°C |
| Outer Jacket Material | PVC - Polyvinyl Chloride |
| Outer Shield | Bi-Laminate (Alum+Poly) Tape, 100% coverage, 20 AWG (19x32) TC drainwire |
| UL Temperature | 60°C |
| UL Voltage Rating | 300 V (CMP) |