23508D Datasheet

BeldenBulk Wire Cable

The Belden 23508D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, constructed with six 18 AWG tinned copper triads, XLPE insulation, individual and overall Beldfoil shields, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It operates from -40 °C to +105 °C dry / 90 °C wet and is used for industrial control, digital control, instruments, encoders, control circuits, DCS/PLC systems, solenoids, valves, actuators, and positioners.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

23508D Key Specifications

Max. Current
2.45 Amps per Conductor at 30ºC
Voltage Rating
300 V
Temperature Operating
-40°C To +105°C Dry/90°C Wet
Bulk Cable Weight
507 lbs/1000ft
Max. Pull Tension
638.2 lbs (289.5 kg)
Nom. Conductor DCR
7.4 Ohm/1000ft
Nom. Inner Shield DCR
6.51 Ohm/1000ft (21.4 Ohm/km)
Overall Cable Diameter (Nominal)
1.078 in

Characteristics (datasheet)

Voltage Rating
300 V
Max. Current
2.45 Amps per Conductor at 30ºC
Nom. Conductor DCR
7.4 Ohm/1000ft
Nom. Inner Shield DCR
6.51 Ohm/1000ft (21.4 Ohm/km)
Temperature Operating
-40°C To +105°C Dry/90°C Wet
Max. Pull Tension
638.2 lbs (289.5 kg)
Overall Cable Diameter (Nominal)
1.078 in
Bulk Cable Weight
507 lbs/1000ft

23508D Applications

  • Industrial Control
  • Raceways Cable trays and ducts
  • Digital Control
  • Instruments (4-20ma, 0-10v)
  • Low voltage digital control (24v)
  • Encoders
  • Control circuits
  • Distributed control system (DCS)
  • Programmable logic controller (PLC)
  • Solenoids
  • Valves
  • Actuators
  • Positioners

Other Belden parts

  • 79025 — The Belden 79025 is a highly flexible 12-conductor, 16 AWG tinned copper cable w...
  • 78022 — The Belden/Alpha Wire 78022 is a 2-conductor 24 AWG tinned copper ECOCABLE with...
  • 58602 — The Belden 58602 is a shielded multi-pair communication and control cable constr...
  • 80164 — The 80164 is a 4-conductor, 10 AWG tinned copper cable with mPPE insulation, an...
  • 9269 — The Belden 9269 is a 93Ω RG-62A/U type coaxial cable featuring a 22 AWG solid ba...
  • 5166C — The Belden 5166C is a shielded, 6-conductor 18 AWG tinned copper cable with PVC...
  • 6000FE — The Belden 6000FE is a plenum-rated security and sound cable designed for indoor...
  • 70060 — The Belden 70060 is a digital audio cable designed for professional studios, use...

More Bulk Wire Cable

  • 5180C — The Belden 5180C is an XTRAGUARD 1 shielded cable featuring 10 conductors of 16...
  • 86202 — The Belden 86202 is a 2-conductor, 24 AWG tinned copper cable with semi-rigid PV...
  • 78114 — The Belden 78114 is a shielded 4-conductor, 26 AWG tinned copper ECOCABLE with m...
  • 28616A — The Belden 28616A is an 8-conductor, 16 AWG (7x24) bare copper cable with PVC/ny...
  • 78388 — The Belden 78388 is an 8-pair, 22 AWG tinned copper conductor cable with modifie...
  • 21597 — The Belden 21597 is a Canadian Instrumentation Cable (TC-CIC) rated 600 V, conta...
  • 8237 — The Belden 8237 is a 50 Ohm RG-8 wireless transmission coaxial cable featuring a...
  • 6506FE — The Belden 6506FE is a plenum-rated (CMP) security and sound cable containing ei...

23508D FAQ

What is 23508D?

23508D is a Bulk Wire Cable from Belden. The Belden 23508D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, constructed with six 18 AWG tinned copper triads, XLPE insulation, individual and overall Beldfoil shields, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It operates from -40 °C to +105 °C dry / 90 °C wet and is used for industrial control, digital control, instruments, encoders, control circuits, DCS/PLC systems, solenoids, valves, actuators, and positioners.

Who manufactures 23508D?

23508D is manufactured by Belden.

Where can I download the 23508D datasheet PDF?

The 23508D datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 23508D specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk Cable Weight507 lbs/1000ft
Max. Current2.45 Amps per Conductor at 30ºC
Max. Pull Tension638.2 lbs (289.5 kg)
Nom. Conductor DCR7.4 Ohm/1000ft
Nom. Inner Shield DCR6.51 Ohm/1000ft (21.4 Ohm/km)
Overall Cable Diameter (Nominal)1.078 in
Temperature Operating-40°C To +105°C Dry/90°C Wet
Voltage Rating300 V