78024 Datasheet

BeldenBulk Wire Cable

The Belden 78024 is a 4-conductor 24 AWG tinned copper ECOCABLE with modified polyphenylene ether (mPPE) insulation and jacket, rated for 300 V. It operates in temperatures from -40°C to +80°C and is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, and automation systems.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

78024 Key Specifications

Nominal capacitance (Cond-to-Cond)
18.9 pF/ft (62.0 pF/m)
Nominal inductance
0.17 µH/ft (0.56 µH/m)
Voltage rating
300 V (AWM 21460, CSA AWM)
Operating Temperature
-40°C To +80°C
UL Temperature Rating
80°C
Conductor count & size
4 conductors, 24 AWG (19x36 strand), TC - Tinned Copper
Insulation material
mPPE - Modified Polyphenylene Ether
Max. Pull Tension
112 lbs (50.8 kg)

78024 Marking Code (SMD Code)

Top marking: Alpha Wire -* P/N 78024 4C 24 AWG ECOCABLE(R) MINI RU AWM 21460 80C 300V VW-1 C(RU) AWM I A/B FT1 80C 300V CE ROHS (SEQ FOOTAGE)

Characteristics (datasheet)

Conductor count & size
4 conductors, 24 AWG (19x36 strand), TC - Tinned Copper
Insulation material
mPPE - Modified Polyphenylene Ether
Outer jacket material
mPPE - Modified Polyphenylene Ether
Nominal capacitance (Cond-to-Cond)
18.9 pF/ft (62.0 pF/m)
Nominal inductance
0.17 µH/ft (0.56 µH/m)
Voltage rating
300 V (AWM 21460, CSA AWM)
Nominal overall diameter
0.128 in (3.25 mm)
Min. bend radius (stationary)
1.3 in (33 mm)

Absolute Maximum Ratings

Max. Pull Tension
112 lbs (50.8 kg)
UL Temperature Rating
80°C
Operating Temperature
-40°C To +80°C
Voltage Rating
300 V (AWM 21460), 300 V (CSA AWM)

78024 Applications

  • Data, communication, audio, and low-level signal transmission
  • Industrial networking
  • Serial communication
  • Control panels
  • Automation equipment
  • Instrumentation systems

Other Belden parts

  • 22633D — Belden 22633D is a Canadian Instrumentation Cable (TC-CIC) rated 300 V with two...
  • 28116A — The Belden 28116A is a 9-conductor, 12 AWG (7x20 stranded bare copper) power and...
  • 6047 — The Belden 6047 is a Teck90 600V, 30+1 conductor cable made of 14 AWG bare coppe...
  • 1747C — The 1747C is a 3-conductor, 18 AWG tinned copper communication and control cable...
  • 9576 — The Belden 9576 is a 6-conductor, 22 AWG solid tinned copper cable with PVC insu...
  • 9443MN — The Belden 9443MN is a SpaceMaker™ 3-conductor cable constructed with 20 AWG tin...
  • 5240FRE — The Belden 5240FRE is a Safe-T-Line fire-resistant multi-conductor cable featuri...
  • 9566 — The Belden 9566 is an audio, control, and instrument cable featuring 24 AWG soli...

More Bulk Wire Cable

  • 8504 — The Belden 8504 is a low-temperature plastic lead wire featuring a 24AWG (7x32)...
  • 78133 — The Belden 78133 is a 3-conductor 22 AWG tinned copper ECOCABLE featuring modifi...
  • 55162 — Belden part 55162 (XTRA GUARD 5) is a 2-conductor, 18 AWG (7x26) tinned copper c...
  • 2202ELV — The Belden 2202ELV is a discontinued Category 6A horizontal and building backbon...
  • 1336A — The Belden 1336A is a 2-conductor 14 AWG tinned copper fieldbus cable with polyp...
  • 1635 — The Belden 1635 is a single-conductor 20 AWG tinned copper hook-up wire with eth...
  • 83041 — The Belden 83041 is a high-temperature plastic lead wire featuring a 32 AWG silv...
  • 45468 — Belden part 45468 is an XTRAGUARD 4 cable with 8 conductors of 20 AWG (7x28) tin...

78024 FAQ

What is 78024?

78024 is a Bulk Wire Cable from Belden. The Belden 78024 is a 4-conductor 24 AWG tinned copper ECOCABLE with modified polyphenylene ether (mPPE) insulation and jacket, rated for 300 V. It operates in temperatures from -40°C to +80°C and is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, and automation systems.

Who manufactures 78024?

78024 is manufactured by Belden.

What is the marking code of 78024?

According to its datasheet, 78024 is marked "Alpha Wire -* P/N 78024 4C 24 AWG ECOCABLE(R) MINI RU AWM 21460 80C 300V VW-1 C(RU) AWM I A/B FT1 80C 300V CE ROHS (SEQ FOOTAGE)".

Where can I download the 78024 datasheet PDF?

The 78024 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 78024 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor count & size4 conductors, 24 AWG (19x36 strand), TC - Tinned Copper
Insulation materialmPPE - Modified Polyphenylene Ether
Max. Pull Tension112 lbs (50.8 kg)
Min. bend radius (stationary)1.3 in (33 mm)
Nominal capacitance (Cond-to-Cond)18.9 pF/ft (62.0 pF/m)
Nominal inductance0.17 µH/ft (0.56 µH/m)
Nominal overall diameter0.128 in (3.25 mm)
Operating Temperature-40°C To +80°C
Outer jacket materialmPPE - Modified Polyphenylene Ether
UL Temperature Rating80°C
Voltage rating300 V (AWM 21460, CSA AWM)