5240FRE Datasheet
The Belden 5240FRE is a Safe-T-Line fire-resistant multi-conductor cable featuring a 1-pair 16 AWG bare copper conductor with ceramifiable silicone insulation and a low smoke zero halogen polyolefin jacket. It is designed for use in fire-resistant applications, including industrial control, raceways, cable trays, ducts, and digital control systems. The cable is rated for a UL voltage of 300 V, supports a maximum current of 19 Amps per conductor, and operates within a temperature range of -20°C to +105°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
5240FRE Key Specifications
- Max. Current
- 19 Amps per Conductor at 30ºC
- UL Voltage Rating
- 300 V
- Operating Temperature
- -20°C to +105°C (UL Temperature 105°C)
- Bulk Cable Weight
- 63 lbs/1000ft (94 kg/km)
- Conductor
- 2 elements, 16 AWG 7x24H Bare Copper (BC)
- Max. Pull Tension
- 94 lbs (43 kg)
- Nom. Conductor DCR
- 4.27 Ohm/1000ft (14.0 Ohm/km)
- Nom Outer Shield DCR
- 5.08 Ohm/1000ft (16.7 Ohm/km)
Characteristics (datasheet)
- Conductor
- 2 elements, 16 AWG 7x24H Bare Copper (BC)
- Nom. Conductor DCR
- 4.27 Ohm/1000ft (14.0 Ohm/km)
- Nom Outer Shield DCR
- 5.08 Ohm/1000ft (16.7 Ohm/km)
- Max. Current
- 19 Amps per Conductor at 30ºC
- UL Voltage Rating
- 300 V
- Operating Temperature
- -20°C to +105°C (UL Temperature 105°C)
- Outer Shield
- Bi-Laminate (Alum+Poly) tape, 100% coverage, 18 AWG (7x26H) TC drain wire
- Outer Jacket
- PO - Polyolefin, Nom. Thickness 0 mm (0.0 in), Nom. Diameter 0.350 in (8.89 mm)
- Bulk Cable Weight
- 63 lbs/1000ft (94 kg/km)
- Max. Pull Tension
- 94 lbs (43 kg)
5240FRE Applications
- Fire resistant applications
- Industrial control
- Raceways, cable trays and ducts
- Digital control
- Instruments (4-20ma, 0-10v)
- Low voltage digital control (24v)
- Encoders
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids
- Valves
- Actuators
- Positioners
Other Belden parts
- 71741ELW — The 71741ELW is a 2-pair 20 AWG tinned copper conductor RS-485 cable with overal...
- 6331 — The Belden 6331 is a multi-conductor communication and control cable featuring s...
- 70075 — The Belden 70075 is a 1-pair AES/EBU digital multi-modulation cable designed for...
- 9612 — The Belden 9612 is a computer EIA RS-232 cable with 24 AWG stranded tinned coppe...
- 87503 — The Belden 87503 (Alpha Wire) is a 3-conductor, 14 AWG XTRAGUARD FLEX flexible t...
- 78015 — The Belden 78015 is a 5-pair 26 AWG ECOCABLE featuring tinned copper conductors...
- 5305C — The Belden 5305C is a 27-conductor, 24 AWG tinned copper multi-conductor cable f...
- 29547 — Belden 29547 is a flexible VFD motor supply cable with three 4/0 AWG tinned copp...
More Bulk Wire Cable
- 34410 — Belden 34410 is a 10 AWG (65x28) stranded tinned copper lead wire with CSPE (chl...
- 3079 — The Belden 3079 is a single-conductor hook-up wire made of 14 AWG stranded tinne...
- 5160C — The Belden 5160C is an XTRAGUARD 1, 10-conductor 20 AWG tinned copper cable with...
- 8019 — The Belden 8019 is a bus bar wire constructed with a single solid 18 AWG tinned...
- 86187CY — The 86187CY is an XTRAGUARD FLEX continuous flex data cable featuring seven 18 A...
- 65204 — The part 65204 is an XTRAGUARD FLEX flexible control cable with 4 conductors of...
- 83905 — The Belden 83905 is a Type K thermocouple pair cable featuring 20 AWG solid Chro...
- 1099A — The Belden 1099A is a UL-listed instrumentation cable featuring 12 triads of 16...
5240FRE FAQ
What is 5240FRE?
5240FRE is a Bulk Wire Cable from Belden. The Belden 5240FRE is a Safe-T-Line fire-resistant multi-conductor cable featuring a 1-pair 16 AWG bare copper conductor with ceramifiable silicone insulation and a low smoke zero halogen polyolefin jacket. It is designed for use in fire-resistant applications, including industrial control, raceways, cable trays, ducts, and digital control systems. The cable is rated for a UL voltage of 300 V, supports a maximum current of 19 Amps per conductor, and operates within a temperature range of -20°C to +105°C.
Who manufactures 5240FRE?
5240FRE is manufactured by Belden.
Where can I download the 5240FRE datasheet PDF?
The 5240FRE datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 5240FRE specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 63 lbs/1000ft (94 kg/km) |
| Conductor | 2 elements, 16 AWG 7x24H Bare Copper (BC) |
| Max. Current | 19 Amps per Conductor at 30ºC |
| Max. Pull Tension | 94 lbs (43 kg) |
| Nom. Conductor DCR | 4.27 Ohm/1000ft (14.0 Ohm/km) |
| Nom Outer Shield DCR | 5.08 Ohm/1000ft (16.7 Ohm/km) |
| Operating Temperature | -20°C to +105°C (UL Temperature 105°C) |
| Outer Jacket | PO - Polyolefin, Nom. Thickness 0 mm (0.0 in), Nom. Diameter 0.350 in (8.89 mm) |
| Outer Shield | Bi-Laminate (Alum+Poly) tape, 100% coverage, 18 AWG (7x26H) TC drain wire |
| UL Voltage Rating | 300 V |