78016 Datasheet

BeldenBulk Wire Cable

The Belden 78016 is a 6-conductor, 26 AWG tinned copper cable with modified polyphenylene ether (mPPE) insulation and a slate mPPE outer jacket, rated for 300 V and an operating temperature range of -40°C to +80°C. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable features a nominal overall diameter of 0.142 inches, a capacitance of 17.6 pF/ft, and complies with UL VW-1 and FT1 flammability standards.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

78016 Key Specifications

Nominal capacitance (cond-to-cond)
17.6 pF/ft (57.7 pF/m)
Nominal inductance
0.18 µH/ft (0.59 µH/m)
Voltage rating
300 V (AWM 21460, CSA AWM)
Operating temperature
-40°C to +80°C (UL temperature 80°C)
Conductor count
6
Conductor size and material
26 AWG (19x38 strand), TC - Tinned Copper
Max pull tension
59 lbs (27 kg)
Nominal overall diameter
0.142 in (3.61 mm)

78016 Marking Code (SMD Code)

Top marking: Alpha Wire -* P/N 78016 6C 26 AWG ECOCABLE(R) MINI RU AWM 21460 80C 300V VW-1 C(RU) AWM I A/B FT1 80C 300V CE ROHS (SEQ FOOTAGE)

Characteristics (datasheet)

Conductor count
6
Conductor size and material
26 AWG (19x38 strand), TC - Tinned Copper
Voltage rating
300 V (AWM 21460, CSA AWM)
Operating temperature
-40°C to +80°C (UL temperature 80°C)
Nominal capacitance (cond-to-cond)
17.6 pF/ft (57.7 pF/m)
Nominal inductance
0.18 µH/ft (0.59 µH/m)
Nominal overall diameter
0.142 in (3.61 mm)
Max pull tension
59 lbs (27 kg)

78016 Applications

  • Data, communication, audio, and low-level signal transmission
  • Industrial networking
  • Serial communication
  • Control panels
  • Automation equipment
  • Instrumentation systems

Other Belden parts

  • 39124 — Belden 39124 is a 24 AWG (7x32) stranded tinned copper lead wire with PPO (polyp...
  • 9341 — The Belden 9341 is a high-performance instrumentation cable featuring a single p...
  • 86005 — The part 86005 is a 5-conductor 28 AWG tinned copper cable with semi-rigid PVC i...
  • 9637 — The Belden 9637 is a computer EIA RS-232 cable featuring 25 stranded tinned copp...
  • 78183 — The Belden 78183 is an ECOCABLE consisting of three pairs of 22 AWG tinned coppe...
  • 3494C — The Belden 3494C is a 4-pair, 28 AWG tinned copper shielded communication and co...
  • 22648D — Belden 22648D is a 300 V Canadian Instrumentation Cable (TC-CIC) with four pairs...
  • 50022L — Belden 50022L is an RS-485 fire-resistant communication cable with two 20 AWG st...

More Bulk Wire Cable

  • 83305E — The Belden 83305E is a high-temperature, single-conductor electronic cable featu...
  • 1862A — The Belden 1862A is an unshielded, plenum-rated (CL3P / CMP) speaker cable consi...
  • 4443FDW — The Belden 4443FDW is an OSDP RS-485 transmission cable designed for use in inst...
  • 9463 — The Belden 9463 Blue Hose® is a 1-pair 20 AWG tinned copper twinax cable with po...
  • 78119 — The Belden 78119 is a 9-pair, 26 AWG stranded tinned copper ECOCABLE designed fo...
  • 77127 — The Belden 77127 is a 4-conductor 18 AWG tinned copper cable with modified polyp...
  • 78152 — The Belden 78152 is an ECOCABLE mini shielded twisted pair cable designed for da...
  • 80066 — The 80066 is a 4-conductor, 10 AWG tinned copper cable with mPPE insulation and...

78016 FAQ

What is 78016?

78016 is a Bulk Wire Cable from Belden. The Belden 78016 is a 6-conductor, 26 AWG tinned copper cable with modified polyphenylene ether (mPPE) insulation and a slate mPPE outer jacket, rated for 300 V and an operating temperature range of -40°C to +80°C. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable features a nominal overall diameter of 0.142 inches, a capacitance of 17.6 pF/ft, and complies with UL VW-1 and FT1 flammability standards.

Who manufactures 78016?

78016 is manufactured by Belden.

What is the marking code of 78016?

According to its datasheet, 78016 is marked "Alpha Wire -* P/N 78016 6C 26 AWG ECOCABLE(R) MINI RU AWM 21460 80C 300V VW-1 C(RU) AWM I A/B FT1 80C 300V CE ROHS (SEQ FOOTAGE)".

Where can I download the 78016 datasheet PDF?

The 78016 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 78016 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor count6
Conductor size and material26 AWG (19x38 strand), TC - Tinned Copper
Max pull tension59 lbs (27 kg)
Nominal capacitance (cond-to-cond)17.6 pF/ft (57.7 pF/m)
Nominal inductance0.18 µH/ft (0.59 µH/m)
Nominal overall diameter0.142 in (3.61 mm)
Operating temperature-40°C to +80°C (UL temperature 80°C)
Voltage rating300 V (AWM 21460, CSA AWM)