77127 Datasheet
The Belden 77127 is a 4-conductor 18 AWG tinned copper cable with modified polyphenylene ether (MPPE) insulation, an overall aluminum/polyester shield, and a slate MPPE outer jacket. It is rated for 600 V and an operating temperature range of -50°C to +105°C. This cable is suitable for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
77127 Key Specifications
- Nom. Capacitance Cond-to-Cond
- 28 pF/ft (92 pF/m)
- Nom. Capacitance Cond-to-Other
- 50 pF/ft (160 pF/m)
- Nom. Inductance
- 0.17 µH/ft (0.56 µH/m)
- Voltage rating
- 600 V (UL AWM 11231, AWM 21915; CSA AWM)
- Operating temperature
- -50°C to +105°C (UL temperature rating: 105°C)
- Conductor count / size
- 4 conductors, 18 AWG (16x30 strand)
- Conductor material
- TC - Tinned Copper
- Insulation material
- mPPE - Modified Polyphenylene Ether
Characteristics (datasheet)
- Conductor count / size
- 4 conductors, 18 AWG (16x30 strand)
- Conductor material
- TC - Tinned Copper
- Insulation material
- mPPE - Modified Polyphenylene Ether
- Outer shield
- Bi-Laminate (Alum+Poly) tape, 100% coverage, with 20 AWG (7x28) TC drainwire
- Outer jacket
- Slate mPPE - Modified Polyphenylene Ether, 0.032 in (0.81 mm) thickness
- Voltage rating
- 600 V (UL AWM 11231, AWM 21915; CSA AWM)
- Operating temperature
- -50°C to +105°C (UL temperature rating: 105°C)
- Nominal overall diameter
- 0.239 in (6.07 mm)
- Nom. Capacitance Cond-to-Cond
- 28 pF/ft (92 pF/m)
- Nom. Capacitance Cond-to-Other
- 50 pF/ft (160 pF/m)
- Nom. Inductance
- 0.17 µH/ft (0.56 µH/m)
- Outer Shield DCR
- 82 Ohm/1000ft (270 Ohm/km)
- Min. bend radius (stationary)
- 2.4 in (61 mm)
- Max. pull tension
- 47 lbs (21 kg)
77127 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 9621 — The Belden 9621 is a 9-conductor electronic cable featuring 16 AWG tinned copper...
- 78019 — The Belden 78019 is an ECOCABLE consisting of 9 pairs of 26 AWG tinned copper co...
- 21635 — Belden part 21635 is a CSA TC-CIC 600 V tray cable with 37 conductors of 10 AWG...
- 1550 — The Belden 1550 is a single-conductor hook-up wire featuring a 24 AWG tinned cop...
- 9945 — The Belden 9945 is a multi-conductor computer EIA RS-232 cable featuring nine 22...
- 1310 — The part 1310 is a heavy-duty RW90 rated power and control cable with a 3/0 AWG...
- 8304 — The Belden 8304 is a computer EIA RS-232 cable with 22 AWG stranded tinned coppe...
- 25164 — Belden 25164 is an XTRAGUARD 2 cable with 4 conductors of 18 AWG (16x30) tinned...
More Bulk Wire Cable
- 4812 — The Belden 4812 is a discontinued Category 6+ enhanced premise horizontal cable...
- 28328A — The 28328A is a Belden UL Type TC power and control cable with 10 conductors of...
- 77126 — The Belden 77126 is a 3-conductor 18 AWG tinned copper cable with mPPE insulatio...
- 21650 — The Belden 21650 is a 600 V Type TC/CIC power and control cable containing two 8...
- 55104 — The Belden 55104 is an XTRAGUARD 5 cable featuring four 22 AWG stranded tinned c...
- 3119A — The Belden 3119A is a DeviceBus® cable designed for InterBus®-S systems, featuri...
- 24500 — Belden 24500 is a Canadian instrumentation cable (TC-ACIC) rated 600 V, built wi...
- 9412 — The Belden 9412 is a high-performance instrumentation cable containing one pair...
77127 FAQ
What is 77127?
77127 is a Bulk Wire Cable from Belden. The Belden 77127 is a 4-conductor 18 AWG tinned copper cable with modified polyphenylene ether (MPPE) insulation, an overall aluminum/polyester shield, and a slate MPPE outer jacket. It is rated for 600 V and an operating temperature range of -50°C to +105°C. This cable is suitable for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
Who manufactures 77127?
77127 is manufactured by Belden.
Where can I download the 77127 datasheet PDF?
The 77127 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 77127 specifications
Click to ask a quick question:
Parameters
| Conductor count / size | 4 conductors, 18 AWG (16x30 strand) |
| Conductor material | TC - Tinned Copper |
| Insulation material | mPPE - Modified Polyphenylene Ether |
| Max. pull tension | 47 lbs (21 kg) |
| Min. bend radius (stationary) | 2.4 in (61 mm) |
| Nom. Capacitance Cond-to-Cond | 28 pF/ft (92 pF/m) |
| Nom. Capacitance Cond-to-Other | 50 pF/ft (160 pF/m) |
| Nominal overall diameter | 0.239 in (6.07 mm) |
| Nom. Inductance | 0.17 µH/ft (0.56 µH/m) |
| Operating temperature | -50°C to +105°C (UL temperature rating: 105°C) |
| Outer jacket | Slate mPPE - Modified Polyphenylene Ether, 0.032 in (0.81 mm) thickness |
| Outer shield | Bi-Laminate (Alum+Poly) tape, 100% coverage, with 20 AWG (7x28) TC drainwire |
| Outer Shield DCR | 82 Ohm/1000ft (270 Ohm/km) |
| Voltage rating | 600 V (UL AWM 11231, AWM 21915; CSA AWM) |