77126 Datasheet

BeldenBulk Wire Cable

The Belden 77126 is a 3-conductor 18 AWG tinned copper cable with mPPE insulation, an overall aluminum/polyester shield, and a slate mPPE outer jacket. It is rated for 600 V and an operating temperature range of -50°C to +105°C, complying with AWM 11231 and AWM 21915 standards. This cable is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, and automation systems.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

77126 Key Specifications

Nominal Capacitance Cond-to-Cond
28 pF/ft (92 pF/m)
Nominal Capacitance Cond-to-Other
50 pF/ft (160 pF/m)
Nominal Inductance
0.17 µH/ft (0.56 µH/m)
Voltage Rating
600 V (AWM 11231, AWM 21915), 600 V (CSA AWM)
Temperature
UL Temperature 105°C, Operating -50°C To +105°C
Conductor
3 Conductor 18 AWG (16x30) TC - Tinned Copper
Nom Outer Shield DCR
82 Ohm/1000ft (270 Ohm/km)
Overall Cable Diameter (Nominal)
0.221 in (5.61 mm)

77126 Marking Code (SMD Code)

Top marking: Alpha Wire -* P/N 77126 3C 18 AWG ECOCABLE(R) RU AWM 21915 105C 600V C(RU) AWM I/II A/B FT2 600V 105C CE ROHS (SEQ FOOTAGE)

Characteristics (datasheet)

Conductor
3 Conductor 18 AWG (16x30) TC - Tinned Copper
Voltage Rating
600 V (AWM 11231, AWM 21915), 600 V (CSA AWM)
Temperature
UL Temperature 105°C, Operating -50°C To +105°C
Nominal Capacitance Cond-to-Cond
28 pF/ft (92 pF/m)
Nominal Capacitance Cond-to-Other
50 pF/ft (160 pF/m)
Nominal Inductance
0.17 µH/ft (0.56 µH/m)
Nom Outer Shield DCR
82 Ohm/1000ft (270 Ohm/km)
Overall Cable Diameter (Nominal)
0.221 in (5.61 mm)

77126 Applications

  • Data, communication, audio, and low-level signal transmission
  • Industrial networking
  • Serial communication
  • Control panels
  • Automation equipment
  • Instrumentation systems

Other Belden parts

  • 89842 — The Belden 89842 is a plenum-rated (CMP) RS-485 cable consisting of two 24 AWG t...
  • 29521 — Belden 29521 is a Premium VFD power cable with three 14 AWG (41 x 30) tinned cop...
  • 25162 — Belden 25162 is an XTRAGUARD 2 two-conductor cable with 18 AWG (16x30) tinned co...
  • 25176 — The Belden 25176 is a 6-conductor 16 AWG (19x29 stranded tinned copper) cable wi...
  • 28123A — The Belden 28123A is a 16-conductor, 12 AWG (7x20) bare copper power and control...
  • 1370P — The Belden 1370P is a serial digital coaxial cable of RG-59 type designed for co...
  • 3107A — The Belden 3107A is a dual-pair 22 AWG tinned copper RS-485 cable with polyethyl...
  • 76401TS — The Belden 76401TS is a highly flexible MachFlex™ dual-conductor cable designed...

More Bulk Wire Cable

  • 86184CY — The Belden 86184CY is a continuous flex data cable featuring four 18 AWG tinned...
  • 58902 — The Belden 58902 is a shielded communication and control cable featuring two pai...
  • 1178C — The 1178C is an 8-conductor, 22 AWG stranded tinned copper communication and con...
  • 78450 — The Belden 78450 is an ECOCABLE consisting of 25 pairs of 20 AWG tinned copper c...
  • 70040 — The Belden 70040 is a microphone cable featuring a single pair of AWG 24 oxygen-...
  • 5094C — The 5094C is a 4-conductor, 24 AWG tinned copper shielded cable with semi-rigid...
  • 80103 — The Belden 80103 (ECOFLEX PUR) is a highly flexible, 2-conductor 26 AWG tinned c...
  • 21592 — Belden part 21592 is a TC-CIC 600 V Canadian instrumentation/control cable. It c...

77126 FAQ

What is 77126?

77126 is a Bulk Wire Cable from Belden. The Belden 77126 is a 3-conductor 18 AWG tinned copper cable with mPPE insulation, an overall aluminum/polyester shield, and a slate mPPE outer jacket. It is rated for 600 V and an operating temperature range of -50°C to +105°C, complying with AWM 11231 and AWM 21915 standards. This cable is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, and automation systems.

Who manufactures 77126?

77126 is manufactured by Belden.

What is the marking code of 77126?

According to its datasheet, 77126 is marked "Alpha Wire -* P/N 77126 3C 18 AWG ECOCABLE(R) RU AWM 21915 105C 600V C(RU) AWM I/II A/B FT2 600V 105C CE ROHS (SEQ FOOTAGE)".

Where can I download the 77126 datasheet PDF?

The 77126 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 77126 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor3 Conductor 18 AWG (16x30) TC - Tinned Copper
Nominal Capacitance Cond-to-Cond28 pF/ft (92 pF/m)
Nominal Capacitance Cond-to-Other50 pF/ft (160 pF/m)
Nominal Inductance0.17 µH/ft (0.56 µH/m)
Nom Outer Shield DCR82 Ohm/1000ft (270 Ohm/km)
Overall Cable Diameter (Nominal)0.221 in (5.61 mm)
TemperatureUL Temperature 105°C, Operating -50°C To +105°C
Voltage Rating600 V (AWM 11231, AWM 21915), 600 V (CSA AWM)