58902 Datasheet

BeldenBulk Wire Cable

The Belden 58902 is a shielded communication and control cable featuring two pairs of 24 AWG tinned copper conductors with FEP insulation, an overall aluminum/polyester shield, and a slate PVDF outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for an operating temperature range of -25°C to +125°C and a UL voltage rating of 300 V (CMP).

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

58902 Key Specifications

UL Voltage Rating
300 V (CMP)
Operating Temperature
-25°C To +125°C (UL Temperature 125°C)
Conductor
2 Pair(s) 24 AWG 7x32 TC - Tinned Copper
Insulation Material
FEP - Fluorinated Ethylene Propylene, 0.012 in (0.30 mm) nominal thickness
Nominal Characteristic Impedance
97 Ohm
Nominal Overall Diameter
0.186 in (4.72 mm)
Outer Jacket
PVDF - Polyvinylidene Fluoride, 0.011 in (0.28 mm) nominal thickness, Slate
Outer Shield
Tape Bi-Laminate (Alum+Poly) 100% coverage, 24 AWG (7x32) TC drainwire

58902 Marking Code (SMD Code)

Top marking: Alpha Wire -* P/N 58902 2PR 24 AWG SHIELDED 125C (UL) TYPE CMP OR C(UL) TYPE CMP FT6 CE ROHS · package Cable (Reel, 500 ft / 1,000 ft variants)

Characteristics (datasheet)

Conductor
2 Pair(s) 24 AWG 7x32 TC - Tinned Copper
Insulation Material
FEP - Fluorinated Ethylene Propylene, 0.012 in (0.30 mm) nominal thickness
Outer Shield
Tape Bi-Laminate (Alum+Poly) 100% coverage, 24 AWG (7x32) TC drainwire
Outer Jacket
PVDF - Polyvinylidene Fluoride, 0.011 in (0.28 mm) nominal thickness, Slate
Nominal Overall Diameter
0.186 in (4.72 mm)
UL Voltage Rating
300 V (CMP)
Operating Temperature
-25°C To +125°C (UL Temperature 125°C)
Nominal Characteristic Impedance
97 Ohm

58902 Applications

  • Data, communication, audio, and low-level signal transmission
  • Industrial networking
  • Serial communication
  • Control panels
  • Automation equipment
  • Instrumentation systems

Other Belden parts

  • 1280 — The Belden 1280 is a heavy-duty power and control cable rated at 1000V, featurin...
  • 27155AS — The Belden 27155AS is a UL Type TC tray cable with two 4 AWG bare copper conduct...
  • 5320C — The Belden 5320C is a highly shielded, multi-conductor cable featuring five 20 A...
  • 1044A — The Belden 1044A is a 20-pair 16 AWG UL-listed instrumentation cable with PVC-ny...
  • 6324 — The Belden 6324 is a shielded communication and control cable consisting of 15 p...
  • 80003 — The Belden 80003 is a 2-conductor, 26 AWG tinned copper cable with mPPE insulati...
  • 78158 — The Belden 78158 is an 8-pair, 28 AWG tinned copper conductor cable (ECOCABLE) w...
  • 38010 — The Belden 38010 is a UL Type PV wire with 10 AWG tinned copper conductors (105x...

More Bulk Wire Cable

  • 5062C — The Belden 5062C is an XTRAGUARD 1, 2-conductor, 18 AWG tinned copper cable with...
  • 9806 — The Belden 9806 is a shielded, 4-pair, 28 AWG stranded tinned copper cable desig...
  • 70080 — The Belden 70080 is a discontinued 75 Ohm SDI coaxial cable of Mini RG-59 type,...
  • 5447 — The Belden 5447 is a 7-conductor, 14 AWG tinned copper cable with PVC insulation...
  • 4642FDW — The Belden 4642FDW is an instrumentation and computer cable designed for OSDP EI...
  • 86608CY — The 86608CY is an XTRAGUARD FLEX continuous flex data cable featuring 8 pairs of...
  • 9759MN — The 9759MN is a SpaceMaker™ 2-pair 16 AWG tinned copper cable with polypropylene...
  • 37540 — The Belden 37540 is a rubber lead wire consisting of a 4/0 AWG tinned copper con...

58902 FAQ

What is 58902?

58902 is a Bulk Wire Cable from Belden. The Belden 58902 is a shielded communication and control cable featuring two pairs of 24 AWG tinned copper conductors with FEP insulation, an overall aluminum/polyester shield, and a slate PVDF outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for an operating temperature range of -25°C to +125°C and a UL voltage rating of 300 V (CMP).

Who manufactures 58902?

58902 is manufactured by Belden.

What is the marking code of 58902?

According to its datasheet, 58902 in Cable (Reel, 500 ft / 1,000 ft variants) is marked "Alpha Wire -* P/N 58902 2PR 24 AWG SHIELDED 125C (UL) TYPE CMP OR C(UL) TYPE CMP FT6 CE ROHS".

Where can I download the 58902 datasheet PDF?

The 58902 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 58902 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor2 Pair(s) 24 AWG 7x32 TC - Tinned Copper
Insulation MaterialFEP - Fluorinated Ethylene Propylene, 0.012 in (0.30 mm) nominal thickness
Nominal Characteristic Impedance97 Ohm
Nominal Overall Diameter0.186 in (4.72 mm)
Operating Temperature-25°C To +125°C (UL Temperature 125°C)
Outer JacketPVDF - Polyvinylidene Fluoride, 0.011 in (0.28 mm) nominal thickness, Slate
Outer ShieldTape Bi-Laminate (Alum+Poly) 100% coverage, 24 AWG (7x32) TC drainwire
UL Voltage Rating300 V (CMP)