21592 Datasheet
Belden part 21592 is a TC-CIC 600 V Canadian instrumentation/control cable. It contains 44 conductors of 12 AWG bare copper (7x20 stranding) plus one 14 AWG bare copper ground wire, with XLPE/XLPO/XLP thermoset insulation and a black PVC outer jacket. It is intended for CEC power and control applications and is rated for indoor, outdoor, sunlight-resistant, and direct-burial use.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
21592 Key Specifications
- Max. Current
- 25 Amps per Conductor at 30ºC
- Voltage Rating
- 600 V (CSA TC)
- Operating Temperature (Wet/Dry)
- -40°C to 90°C
- Bulk Cable Weight
- 1478 lbs/1000ft (2200 kg/km)
- Conductors
- 44 conductor(s) 12 AWG, 7x20 BC - Bare Copper; Ground Wire 1, 14 AWG 7x22 BC - Bare Copper
- Insulation
- XLP, XLPO, XLPE (Thermoset); Nom. Thickness 0.032 in (0.81 mm); Nom. Insulation Diameter 0.150 in (3.81 mm)
- Nom. Conductor DCR
- 1.6 Ohm/1000ft (5.2 Ohm/km)
- Outer Jacket
- PVC - Polyvinyl Chloride, Nom. Thickness 0.095 in (2.4 mm), Ripcord Yes
Characteristics (datasheet)
- Voltage Rating
- 600 V (CSA TC)
- Conductors
- 44 conductor(s) 12 AWG, 7x20 BC - Bare Copper; Ground Wire 1, 14 AWG 7x22 BC - Bare Copper
- Max. Current
- 25 Amps per Conductor at 30ºC
- Nom. Conductor DCR
- 1.6 Ohm/1000ft (5.2 Ohm/km)
- Insulation
- XLP, XLPO, XLPE (Thermoset); Nom. Thickness 0.032 in (0.81 mm); Nom. Insulation Diameter 0.150 in (3.81 mm)
- Outer Jacket
- PVC - Polyvinyl Chloride, Nom. Thickness 0.095 in (2.4 mm), Ripcord Yes
- Operating Temperature (Wet/Dry)
- -40°C to 90°C
- Bulk Cable Weight
- 1478 lbs/1000ft (2200 kg/km)
21592 Applications
- CEC Power and Control Applications
Other Belden parts
- 85803 — The Belden 85803 is a 3-conductor, 18 AWG XTRAGUARD FLEX continuous flex control...
- 9116 — The Belden 9116 is a Series 6 broadband coaxial cable designed for broadband, ca...
- 65245CY — The Belden 65245CY is a 5-conductor, 24 AWG XTRAGUARD FLEX flexible control cabl...
- 79251 — The Belden 79251 is a 3-conductor, 24 AWG tinned copper cable with mPPE insulati...
- 1600 — The Belden 1600 is a heavy-duty 600V, 2/0 AWG bare copper cable with PVC insulat...
- 9259 — The Belden 9259 is a 75 Ohm analog video coaxial cable (RG-59) featuring a 22 AW...
- 1099A — The Belden 1099A is a UL-listed instrumentation cable featuring 12 triads of 16...
- 8138 — The Belden 8138 is an EIA RS-232/485 computer cable consisting of 8 pairs of 28...
More Bulk Wire Cable
- 8625MN — The Belden 8625MN is a SpaceMaker™ 5-conductor cable with 16AWG tinned copper co...
- 8428 — The Belden 8428 is a 2-conductor, 18 AWG stranded tinned copper microphone cable...
- 6051 — The Belden 6051 is a Teck90 600V cable designed for CEC power and control applic...
- 78032 — The Belden 78032 is a 2-conductor 22 AWG tinned copper cable with modified polyp...
- 83609 — The Belden 83609 is a high-temperature plenum-rated (CMP) 9-conductor electronic...
- 5196C — The Belden 5196C (Alpha Wire) is a 6-conductor, 22 AWG tinned copper cable with...
- 86107CY — The Belden 86107CY is a continuous flex data cable featuring 7 conductors of 26...
- 4508FE — The Belden 4508FE is a security and commercial audio cable featuring 10 conducto...
21592 FAQ
What is 21592?
21592 is a Bulk Wire Cable from Belden. Belden part 21592 is a TC-CIC 600 V Canadian instrumentation/control cable. It contains 44 conductors of 12 AWG bare copper (7x20 stranding) plus one 14 AWG bare copper ground wire, with XLPE/XLPO/XLP thermoset insulation and a black PVC outer jacket. It is intended for CEC power and control applications and is rated for indoor, outdoor, sunlight-resistant, and direct-burial use.
Who manufactures 21592?
21592 is manufactured by Belden.
Where can I download the 21592 datasheet PDF?
The 21592 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 21592 specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 1478 lbs/1000ft (2200 kg/km) |
| Conductors | 44 conductor(s) 12 AWG, 7x20 BC - Bare Copper; Ground Wire 1, 14 AWG 7x22 BC - Bare Copper |
| Insulation | XLP, XLPO, XLPE (Thermoset); Nom. Thickness 0.032 in (0.81 mm); Nom. Insulation Diameter 0.150 in (3.81 mm) |
| Max. Current | 25 Amps per Conductor at 30ºC |
| Nom. Conductor DCR | 1.6 Ohm/1000ft (5.2 Ohm/km) |
| Operating Temperature (Wet/Dry) | -40°C to 90°C |
| Outer Jacket | PVC - Polyvinyl Chloride, Nom. Thickness 0.095 in (2.4 mm), Ripcord Yes |
| Voltage Rating | 600 V (CSA TC) |