6071 Datasheet
The Belden 6071 is a Teck90 1000V power and control cable featuring three 10 AWG and one 12 AWG bare copper conductors with XLPE insulation, a PVC inner jacket, steel interlock armor, and a black PVC outer jacket. It is designed for indoor and outdoor use, offering excellent sunlight and UV resistance. The cable operates within a temperature range of -40°C to +90°C and can handle a maximum current of 40 Amps per conductor at 30°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
6071 Key Specifications
- Conductor DC Resistance
- 1.06 Ohm/1000ft (conductor), 1.68 Ohm/1000ft (ground wire)
- Max Current
- 40 Amps per Conductor at 30ºC
- Voltage Rating
- 1000 V (TECK 90)
- Operating Temperature Range
- -40°C To +90°C (UL temperature 90°C)
- Bulk Cable Weight
- 564 lbs/1000ft
- Conductor Configuration
- 3 conductors of 10 AWG (7x18 strand) + 1 ground wire of 12 AWG (7x20 strand), bare copper
- Max Pull Tension
- 717.2 lbs (325.3 kg)
- Overall Nominal Diameter
- 0.886 in
Characteristics (datasheet)
- Voltage Rating
- 1000 V (TECK 90)
- Conductor Configuration
- 3 conductors of 10 AWG (7x18 strand) + 1 ground wire of 12 AWG (7x20 strand), bare copper
- Max Current
- 40 Amps per Conductor at 30ºC
- Conductor DC Resistance
- 1.06 Ohm/1000ft (conductor), 1.68 Ohm/1000ft (ground wire)
- Operating Temperature Range
- -40°C To +90°C (UL temperature 90°C)
- Overall Nominal Diameter
- 0.886 in
- Bulk Cable Weight
- 564 lbs/1000ft
- Max Pull Tension
- 717.2 lbs (325.3 kg)
6071 Applications
- CEC Power and Control Applications
Other Belden parts
- 5486C — The Belden 5486C is a XTRAGUARD 1 shielded multi-conductor cable featuring 6 pai...
- 6309 — The Belden 6309 is a 25-conductor, 24 AWG tinned copper cable with semi-rigid PV...
- 5328UL — The Belden 5328UL is a fire alarm cable with a riser classification (FPLR), cons...
- 5106C — The 5106C is a 6-conductor, 22 AWG tinned copper shielded cable with semi-rigid...
- 934059102 — Blue 60V 32A 250mm Test Probe Lead
- 8668 — The Belden 8668 is a tinned copper braid conductor with a size of 13.3 AWG (120x...
- 934075109 — HIRSCHMANN TEST AND MEASUREMENT 934075109 Test Lead, 4mm Bana...
- 21647 — The Belden 21647 is a CSA Type TC-CIC 600 V power and control tray cable contain...
More Bulk Wire Cable
- 8919 — The Belden 8919 is a low temperature plastic lead wire featuring a 20 AWG tinned...
- 5624UG — The Belden 5624UG is a nurse call and paging cable rated for CM applications, co...
- 21585 — Belden 21585 is a CSA Type TC-CIC tray cable rated 600 V with 37 conductors plus...
- 9265 — The Belden 9265 is a composite cable designed for ENG, EFP, and CCTV application...
- 86107CY — The Belden 86107CY is a continuous flex data cable featuring 7 conductors of 26...
- 80033 — The Belden 80033 is a 3-conductor, 18 AWG tinned copper control cable with mPPE...
- 5507 — The Belden 5507 is a 7-conductor, 22 AWG tinned copper cable with PVC insulation...
- 58414 — The Belden 58414 is a plenum-rated, overall shielded communication and control c...
6071 FAQ
What is 6071?
6071 is a Bulk Wire Cable from Belden. The Belden 6071 is a Teck90 1000V power and control cable featuring three 10 AWG and one 12 AWG bare copper conductors with XLPE insulation, a PVC inner jacket, steel interlock armor, and a black PVC outer jacket. It is designed for indoor and outdoor use, offering excellent sunlight and UV resistance. The cable operates within a temperature range of -40°C to +90°C and can handle a maximum current of 40 Amps per conductor at 30°C.
Who manufactures 6071?
6071 is manufactured by Belden.
Where can I download the 6071 datasheet PDF?
The 6071 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 6071 specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 564 lbs/1000ft |
| Conductor Configuration | 3 conductors of 10 AWG (7x18 strand) + 1 ground wire of 12 AWG (7x20 strand), bare copper |
| Conductor DC Resistance | 1.06 Ohm/1000ft (conductor), 1.68 Ohm/1000ft (ground wire) |
| Max Current | 40 Amps per Conductor at 30ºC |
| Max Pull Tension | 717.2 lbs (325.3 kg) |
| Operating Temperature Range | -40°C To +90°C (UL temperature 90°C) |
| Overall Nominal Diameter | 0.886 in |
| Voltage Rating | 1000 V (TECK 90) |