6309 Datasheet
The Belden 6309 is a 25-conductor, 24 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and supports operating temperatures from -20°C to +80°C. This communication and control cable is designed for data, audio, and low-level signal transmission in industrial networking, automation equipment, and instrumentation systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
6309 Key Specifications
- Nominal conductor-to-conductor capacitance
- 31 pF/ft (100 pF/m)
- Voltage rating
- 300 V (CMG, CM, AWM 2464)
- Operating temperature
- -20°C to +80°C (UL temperature 80°C)
- Conductor configuration
- 25 conductors, 24 AWG (7x32) TC - Tinned Copper
- Max pull tension
- 10.8 lbs (4.90 kg)
- Minimum stationary bend radius
- 3.3 in (84 mm)
- Nominal outer diameter
- 0.332 in (8.43 mm)
- Shielding
- Overall Bi-Laminate (Alum+Poly) 100% coverage with 24 AWG (7x32) TC drainwire
6309 Marking Code (SMD Code)
Top marking: Alpha Wire -* P/N 6309 25C 24 AWG SHIELDED 75C (UL) TYPE CM OR AWM 2464 OR C(UL) 60C TYPE CMG FT4 CE ROHS · package Reel (variants: 100 ft, 500 ft, 1,000 ft)
Characteristics (datasheet)
- Conductor configuration
- 25 conductors, 24 AWG (7x32) TC - Tinned Copper
- Voltage rating
- 300 V (CMG, CM, AWM 2464)
- Operating temperature
- -20°C to +80°C (UL temperature 80°C)
- Nominal outer diameter
- 0.332 in (8.43 mm)
- Shielding
- Overall Bi-Laminate (Alum+Poly) 100% coverage with 24 AWG (7x32) TC drainwire
- Max pull tension
- 10.8 lbs (4.90 kg)
- Minimum stationary bend radius
- 3.3 in (84 mm)
- Nominal conductor-to-conductor capacitance
- 31 pF/ft (100 pF/m)
6309 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 9901 — The Belden 9901 is an IEEE 802.3 Ethernet transceiver cable designed specificall...
- 7953A — The Belden 7953A is an Industrial Ethernet Category 6 cable constructed with fou...
- 6148 — The Belden 6148 is a heavy-duty Teck90 600V cable featuring 50 bare copper condu...
- 23511D — The Belden 23511D is a Canadian TC-ACIC 300 V instrumentation cable with 2 pairs...
- 70046 — The Belden 70046 is a flexible, low smoke zero halogen (LSZH) speaker cable with...
- 1527A — The Belden 1527A is a UL-listed instrumentation cable consisting of three 16 AWG...
- 78760ELZ — The 78760ELZ is a 2-conductor 18 AWG tinned copper electronic cable with foam po...
- 78016 — The Belden 78016 is a 6-conductor, 26 AWG tinned copper cable with modified poly...
More Bulk Wire Cable
- 5363C — The Belden 5363C is a heavy-duty, shielded 3-conductor cable built with 16 AWG s...
- 1811A — The Belden 1811A is a discontinued speaker cable consisting of eight 14 AWG stra...
- 21678 — Belden 21678 is a CSA TC-CIC 600 V tray cable with three 4/0 AWG bare copper pow...
- 82489 — The Belden 82489 is a 4-conductor 18 AWG tinned copper electronic cable with FEP...
- 1883A — The Belden 1883A is a line level audio cable with a single pair of 24 AWG tinned...
- 80132 — The Belden 80132 is a zero-halogen, 2-conductor 18 AWG tinned copper cable with...
- 5624UG — The Belden 5624UG is a nurse call and paging cable rated for CM applications, co...
- 77010 — The Belden 77010 is a 7-conductor, 22 AWG ECOCABLE featuring tinned copper condu...
6309 FAQ
What is 6309?
6309 is a Bulk Wire Cable from Belden. The Belden 6309 is a 25-conductor, 24 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and supports operating temperatures from -20°C to +80°C. This communication and control cable is designed for data, audio, and low-level signal transmission in industrial networking, automation equipment, and instrumentation systems.
Who manufactures 6309?
6309 is manufactured by Belden.
What is the marking code of 6309?
According to its datasheet, 6309 in Reel (variants: 100 ft, 500 ft, 1,000 ft) is marked "Alpha Wire -* P/N 6309 25C 24 AWG SHIELDED 75C (UL) TYPE CM OR AWM 2464 OR C(UL) 60C TYPE CMG FT4 CE ROHS".
Where can I download the 6309 datasheet PDF?
The 6309 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 6309 specifications
Click to ask a quick question:
Parameters
| Conductor configuration | 25 conductors, 24 AWG (7x32) TC - Tinned Copper |
| Max pull tension | 10.8 lbs (4.90 kg) |
| Minimum stationary bend radius | 3.3 in (84 mm) |
| Nominal conductor-to-conductor capacitance | 31 pF/ft (100 pF/m) |
| Nominal outer diameter | 0.332 in (8.43 mm) |
| Operating temperature | -20°C to +80°C (UL temperature 80°C) |
| Shielding | Overall Bi-Laminate (Alum+Poly) 100% coverage with 24 AWG (7x32) TC drainwire |
| Voltage rating | 300 V (CMG, CM, AWM 2464) |