6049 Datasheet
The Belden 6049 is a Teck90 600V cable featuring 50 bare copper conductors plus ground wires, designed specifically for CEC power and control applications. It utilizes XLPE insulation with a color code of black and numbered, a PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket. The cable is rated for operating temperatures between -40°C and +90°C, provides sunlight resistance, and is compliant with CSA HL and FT4 flammability standards.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
6049 Key Specifications
- Max. Current
- 21 Amps per Conductor at 30ºC
- Voltage Rating
- 600V (Teck90)
- Operating Temperature
- -40°C To +90°C
- Armor Thickness
- 0.034 in (0.86 mm) (AIA - Aluminum Interlock Armor)
- Bulk Cable Weight
- 1957 lbs/1000ft (2912 kg/km)
- Conductor Configuration
- 50 Conductors of 12 AWG (7x20.5) and Ground wires of 14 AWG (7x22) and 12 AWG (7x20), BC - Bare Copper
- Insulation Nom. Thickness
- 0.030 in (0.76 mm) (XLP, XLPO, XLPE)
- Outer Jacket Nom. Thickness
- 0.053 in (1.3 mm) (PVC - Polyvinyl Chloride)
Characteristics (datasheet)
- Voltage Rating
- 600V (Teck90)
- Max. Current
- 21 Amps per Conductor at 30ºC
- Operating Temperature
- -40°C To +90°C
- Bulk Cable Weight
- 1957 lbs/1000ft (2912 kg/km)
- Armor Thickness
- 0.034 in (0.86 mm) (AIA - Aluminum Interlock Armor)
- Outer Jacket Nom. Thickness
- 0.053 in (1.3 mm) (PVC - Polyvinyl Chloride)
- Insulation Nom. Thickness
- 0.030 in (0.76 mm) (XLP, XLPO, XLPE)
- Conductor Configuration
- 50 Conductors of 12 AWG (7x20.5) and Ground wires of 14 AWG (7x22) and 12 AWG (7x20), BC - Bare Copper
6049 Applications
- CEC Power and Control Applications
Other Belden parts
- 3054A — The 3054A is a UL-listed instrumentation and control cable containing 24 triads...
- 6319 — The Belden 6319 is a communication and control cable designed for data, communic...
- 9536 — The Belden 9536 is a computer EIA RS-232 cable featuring six 24 AWG stranded tin...
- 77226 — The Belden 77226 is a 7-conductor, 16 AWG tinned copper ECOCABLE featuring mPPE...
- 29507 — Belden 29507 is a flexible 600/1000 V TC-ER WTTC motor supply cable built with t...
- 3444 — The Belden 3444 is a shielded, 4-conductor, 16 AWG tinned copper cable with PVC...
- 50098TPE — The Belden 50098TPE is a 2-core, 2.5 mm² AS-Interface bus flat cable with strand...
- 1097A — The Belden 1097A is a UL-listed instrumentation cable consisting of four 16 AWG...
More Bulk Wire Cable
- 78249 — The Belden 78249 is a high-performance 9-pair 20 AWG tinned copper cable with mo...
- 29723C — The Belden 29723C is a 3-conductor VFD power cable built with 10 AWG (7x18) bare...
- 70032 — The Belden 70032 is a discontinued analog audio cable featuring four pairs of 26...
- 9335 — The Belden 9335 is a high-performance instrumentation cable featuring 19 pairs o...
- 27152A — The Belden 27152A is a UL Type TC power and control cable with two 6 AWG bare co...
- 5496C — The Belden 5496C is an XTRAGUARD 1 semi-rigid multi-conductor cable consisting o...
- 82444 — The Belden 82444 is a 4-conductor, 22 AWG (7x30 stranded) tinned copper electron...
- 77102 — The Belden 77102 is a shielded dual-conductor cable (ECOCABLE) built with two 24...
6049 FAQ
What is 6049?
6049 is a Bulk Wire Cable from Belden. The Belden 6049 is a Teck90 600V cable featuring 50 bare copper conductors plus ground wires, designed specifically for CEC power and control applications. It utilizes XLPE insulation with a color code of black and numbered, a PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket. The cable is rated for operating temperatures between -40°C and +90°C, provides sunlight resistance, and is compliant with CSA HL and FT4 flammability standards.
Who manufactures 6049?
6049 is manufactured by Belden.
Where can I download the 6049 datasheet PDF?
The 6049 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 6049 specifications
Click to ask a quick question:
Parameters
| Armor Thickness | 0.034 in (0.86 mm) (AIA - Aluminum Interlock Armor) |
| Bulk Cable Weight | 1957 lbs/1000ft (2912 kg/km) |
| Conductor Configuration | 50 Conductors of 12 AWG (7x20.5) and Ground wires of 14 AWG (7x22) and 12 AWG (7x20), BC - Bare Copper |
| Insulation Nom. Thickness | 0.030 in (0.76 mm) (XLP, XLPO, XLPE) |
| Max. Current | 21 Amps per Conductor at 30ºC |
| Operating Temperature | -40°C To +90°C |
| Outer Jacket Nom. Thickness | 0.053 in (1.3 mm) (PVC - Polyvinyl Chloride) |
| Voltage Rating | 600V (Teck90) |