3054A Datasheet

BeldenBulk Wire Cable

The 3054A is a UL-listed instrumentation and control cable containing 24 triads of 16 AWG and one 22 AWG bare copper conductors with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is designed for industrial control, raceways, digital control, instruments, RTD, and control circuits, with a voltage rating of 300V (CMG, PLTC) or 150V (ITC) and an operating temperature range of -30°C to +105°C.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

3054A Key Specifications

Voltage Rating
300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
Operating Temperature
-30°C to +105°C (UL Temperature: 105°C)
Bulk Cable Weight / Max. Pull Tension
1025 lbs/1000ft / 2615 lbs (1186 kg)
Conductor structure
24 Triad(s) 16 AWG 7x24 BC - Bare Copper, 1 Comm Wire(s) 22 AWG 7x30 BC - Bare Copper
Insulation
PVC - Polyvinyl Chloride (Triad(s): 0.017 in (0.43 mm), Comm Wire(s): 0.015 in (0.38 mm))
Nominal Overall Diameter
1.230 in (31.24 mm)
Outer Jacket
PVC - Polyvinyl Chloride, 0.073 in (1.9 mm) nominal thickness, Black, with Ripcord
Outer Shield
Tape, Bi-Laminate (Alum+Poly), 100% coverage, 16 AWG (7x24) TC drainwire

Characteristics (datasheet)

Conductor structure
24 Triad(s) 16 AWG 7x24 BC - Bare Copper, 1 Comm Wire(s) 22 AWG 7x30 BC - Bare Copper
Insulation
PVC - Polyvinyl Chloride (Triad(s): 0.017 in (0.43 mm), Comm Wire(s): 0.015 in (0.38 mm))
Outer Shield
Tape, Bi-Laminate (Alum+Poly), 100% coverage, 16 AWG (7x24) TC drainwire
Outer Jacket
PVC - Polyvinyl Chloride, 0.073 in (1.9 mm) nominal thickness, Black, with Ripcord
Nominal Overall Diameter
1.230 in (31.24 mm)
Voltage Rating
300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
Operating Temperature
-30°C to +105°C (UL Temperature: 105°C)
Bulk Cable Weight / Max. Pull Tension
1025 lbs/1000ft / 2615 lbs (1186 kg)

3054A Applications

  • Industrial control
  • Raceways Cable trays and ducts
  • Digital control
  • Instruments (4-20ma, 0-10v, ...)
  • low voltage digital control (24v, …)
  • control circuits
  • distributed control system (DCS)
  • programmable logic controller (PLC)
  • Solenoids
  • Valves
  • actuators
  • positioners

Other Belden parts

  • 82842 — The Belden 82842 is a plenum-rated (CMP) RS-485 cable featuring two pairs of 24...
  • 6144 — The Belden 6144 is a Teck90 1000V industrial cable featuring three 1/0 AWG bare...
  • 58140A — The Belden 58140A is a 4-conductor, 10 AWG bare copper cable with PVC-Nylon insu...
  • 5444 — The Belden 5444 is a 4-conductor, 14 AWG tinned copper cable with PVC insulation...
  • 9309 — The Belden 9309 is an audio, control, and instrument cable featuring 22 AWG soli...
  • 35196 — Belden part 35196 is an XTRAGUARD 3 cable with six 22 AWG (7x30) tinned copper c...
  • 1865A — The Belden 1865A is a sub-miniature serial digital coaxial cable (RG Type: Sub-m...
  • 9903 — The Belden 9903 is an IEEE 802.3 Ethernet transceiver cable designed for 10BASE5...

More Bulk Wire Cable

  • 29523 — Belden part 29523 is a premium VFD power cable built for variable frequency driv...
  • 1269A — The Belden 1269A is a plenum-rated computer POS cable featuring 22 AWG solid tin...
  • 80061 — The Belden 80061 is a 4-conductor, 12 AWG tinned copper control cable featuring...
  • 83562 — The Belden 83562 is a high-temperature, shielded multi-conductor cable featuring...
  • 77213 — The part 77213 is a 2-conductor 18 AWG tinned copper cable with mPPE insulation,...
  • 6376 — The Belden 6376 is a communication and control cable with 5 pairs of 22 AWG tinn...
  • 3109A — The Belden 3109A is an RS-485 communication cable consisting of 4 pairs of 22 AW...
  • 74035PU — The Belden 74035PU is a high-flexible, double-shielded single pair Ethernet (SPE...

3054A FAQ

What is 3054A?

3054A is a Bulk Wire Cable from Belden. The 3054A is a UL-listed instrumentation and control cable containing 24 triads of 16 AWG and one 22 AWG bare copper conductors with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is designed for industrial control, raceways, digital control, instruments, RTD, and control circuits, with a voltage rating of 300V (CMG, PLTC) or 150V (ITC) and an operating temperature range of -30°C to +105°C.

Who manufactures 3054A?

3054A is manufactured by Belden.

Where can I download the 3054A datasheet PDF?

The 3054A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 3054A specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk Cable Weight / Max. Pull Tension1025 lbs/1000ft / 2615 lbs (1186 kg)
Conductor structure24 Triad(s) 16 AWG 7x24 BC - Bare Copper, 1 Comm Wire(s) 22 AWG 7x30 BC - Bare Copper
InsulationPVC - Polyvinyl Chloride (Triad(s): 0.017 in (0.43 mm), Comm Wire(s): 0.015 in (0.38 mm))
Nominal Overall Diameter1.230 in (31.24 mm)
Operating Temperature-30°C to +105°C (UL Temperature: 105°C)
Outer JacketPVC - Polyvinyl Chloride, 0.073 in (1.9 mm) nominal thickness, Black, with Ripcord
Outer ShieldTape, Bi-Laminate (Alum+Poly), 100% coverage, 16 AWG (7x24) TC drainwire
Voltage Rating300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)