5308UE Datasheet
The 5308UE is a riser-CMR rated security and sound cable featuring 10 stranded bare copper conductors (18 AWG) with polyolefin insulation and a PVC outer jacket with a ripcord. It is designed for indoor riser use, suitable for security systems, intercom/PA systems, audio/speaker setups, and power-limited controls. The cable supports a UL voltage rating of 300 V and a maximum current of 9.8 Amps per conductor at 25°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
5308UE Key Specifications
- Max. Current
- 9.8 Amps per conductor @ 25°C
- Nom. Capacitance Cond-to-Cond
- 30 pF/ft (98 pF/m)
- UL Voltage Rating
- 300 V
- UL Temperature / Operating
- 75°C / -20°C to +75°C
- Bend Radius (Stationary Min. / Installation Min.)
- 2.8 in (71 mm) / 2.8 in (71 mm)
- Bulk Cable Weight
- 67 lbs/1000ft
- Conductors
- 10 elements, 18 AWG, 7x26 stranded, BC - Bare Copper
- Insulation
- PO - Polyolefin, Nom. Thickness 0.009 in (0.23 mm), Nom. Insulation Diameter 0.062 in (1.6 mm)
Characteristics (datasheet)
- Conductors
- 10 elements, 18 AWG, 7x26 stranded, BC - Bare Copper
- Insulation
- PO - Polyolefin, Nom. Thickness 0.009 in (0.23 mm), Nom. Insulation Diameter 0.062 in (1.6 mm)
- Outer Jacket
- PVC - Polyvinyl Chloride, Nom. Thickness 0.018 in (0.46 mm), Nom. Diameter 0.284 in (7.21 mm), Ripcord: Yes
- Overall Cable Diameter (Nominal)
- 0.284 in (7.21 mm)
- Nom. Conductor DCR
- 6.5 Ohm/1000ft
- Nom. Capacitance Cond-to-Cond
- 30 pF/ft (98 pF/m)
- Max. Current
- 9.8 Amps per conductor @ 25°C
- UL Voltage Rating
- 300 V
- UL Temperature / Operating
- 75°C / -20°C to +75°C
- Bend Radius (Stationary Min. / Installation Min.)
- 2.8 in (71 mm) / 2.8 in (71 mm)
- Max. Pull Tension
- 224 lbs (102 kg)
- Bulk Cable Weight
- 67 lbs/1000ft
5308UE Applications
- Security System
- Intercom/PA
- Audio/Speaker
- Power-Limited Controls
Other Belden parts
- 2827 — The Belden 2827 is a single-conductor communication and control cable designed f...
- 7795A — The Belden 7795A is a digital coax snake cable with a riser-CMR rating, featurin...
- 83002 — The Belden 83002 is a high-temperature plastic lead wire (AWM 1213) featuring a...
- 28326A — The Belden 28326A is a 4-conductor, 18 AWG (7x26 stranded bare copper) power and...
- 3035A — The 3035A is a UL instrumentation cable consisting of 16 pairs of 18 AWG and one...
- 5000FE — The Belden 5000FE is a commercial security and audio riser cable (rated CL3R-FPL...
- 1282 — The Belden 1282 is a 12-conductor, 14 AWG tinned copper communication and contro...
- 5584C — The Belden 5584C is an XTRAGUARD 1 shielded multi-conductor cable featuring 19 c...
More Bulk Wire Cable
- 74043E — The Belden 74043E is an industrial-grade DataTuff Single Pair Ethernet (SPE) cab...
- 28168A — The Belden 28168A is a UL Type TC (1277) power and control cable with three 1/0...
- 5096C — The Belden 5096C is a shielded, multi-conductor cable featuring 6 conductors of...
- 83503 — The Belden 83503 is a high-temperature, shielded 3-conductor electronic cable fe...
- 79023 — The Belden 79023 is a 7-conductor 16 AWG tinned copper cable with mPPE insulatio...
- 7814A — The Belden 7814A is a Category 6 indoor horizontal cable featuring four pairs of...
- 6053 — The Belden 6053 is a Teck90 600V heavy-duty cable featuring four 12 AWG bare cop...
- 21633 — The Belden 21633 is a CSA TC-CIC 600 V tray cable containing 35 conductors of 10...
5308UE FAQ
What is 5308UE?
5308UE is a Bulk Wire Cable from Belden. The 5308UE is a riser-CMR rated security and sound cable featuring 10 stranded bare copper conductors (18 AWG) with polyolefin insulation and a PVC outer jacket with a ripcord. It is designed for indoor riser use, suitable for security systems, intercom/PA systems, audio/speaker setups, and power-limited controls. The cable supports a UL voltage rating of 300 V and a maximum current of 9.8 Amps per conductor at 25°C.
Who manufactures 5308UE?
5308UE is manufactured by Belden.
Where can I download the 5308UE datasheet PDF?
The 5308UE datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 5308UE specifications
Click to ask a quick question:
Parameters
| Bend Radius (Stationary Min. / Installation Min.) | 2.8 in (71 mm) / 2.8 in (71 mm) |
| Bulk Cable Weight | 67 lbs/1000ft |
| Conductors | 10 elements, 18 AWG, 7x26 stranded, BC - Bare Copper |
| Insulation | PO - Polyolefin, Nom. Thickness 0.009 in (0.23 mm), Nom. Insulation Diameter 0.062 in (1.6 mm) |
| Max. Current | 9.8 Amps per conductor @ 25°C |
| Max. Pull Tension | 224 lbs (102 kg) |
| Nom. Capacitance Cond-to-Cond | 30 pF/ft (98 pF/m) |
| Nom. Conductor DCR | 6.5 Ohm/1000ft |
| Outer Jacket | PVC - Polyvinyl Chloride, Nom. Thickness 0.018 in (0.46 mm), Nom. Diameter 0.284 in (7.21 mm), Ripcord: Yes |
| Overall Cable Diameter (Nominal) | 0.284 in (7.21 mm) |
| UL Temperature / Operating | 75°C / -20°C to +75°C |
| UL Voltage Rating | 300 V |