3308 Datasheet
The Belden 3308 is an 8-conductor, 28 AWG tinned copper communication and control cable with PVC insulation, overall tinned copper braid shield, and a black and red PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, suitable for industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for 600 V and operates within a temperature range of -55°C to +105°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
3308 Key Specifications
- Nom. Capacitance Cond-to-Cond
- 29 pF/ft (95 pF/m)
- Nom. Capacitance Cond-to-Other
- 52 pF/ft (170 pF/m)
- Nom. Inductance
- 0.22 µH/ft (0.72 µH/m)
- Voltage Rating
- 600 V (MIL-SPEC)
- Operating Temperature
- -55°C to +105°C
- Conductor
- 8 conductor, 28 AWG (7x36) tinned copper (TC)
- Nom Outer Shield DCR
- 56 Ohm/1000ft (180 Ohm/km)
- Overall Cable Diameter (Nominal)
- 0.171 in (4.34 mm)
3308 Marking Code (SMD Code)
Top marking: Alpha Wire -* P/N 3308 CE ROHS
Characteristics (datasheet)
- Conductor
- 8 conductor, 28 AWG (7x36) tinned copper (TC)
- Voltage Rating
- 600 V (MIL-SPEC)
- Nom. Capacitance Cond-to-Cond
- 29 pF/ft (95 pF/m)
- Nom. Capacitance Cond-to-Other
- 52 pF/ft (170 pF/m)
- Nom. Inductance
- 0.22 µH/ft (0.72 µH/m)
- Nom Outer Shield DCR
- 56 Ohm/1000ft (180 Ohm/km)
- Operating Temperature
- -55°C to +105°C
- Overall Cable Diameter (Nominal)
- 0.171 in (4.34 mm)
3308 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 29502 — Belden part 29502 is a flexible motor supply VFD cable with three 12 AWG (65x30)...
- 79215FLW — The 79215FLW is a Safe-T-Line shielded, fire-resistant multi-conductor cable des...
- 4443FDW — The Belden 4443FDW is an OSDP RS-485 transmission cable designed for use in inst...
- 9221 — The Belden 9221 is a coaxial analog video cable suitable for composite video and...
- 9434 — The Belden 9434 is a 50-conductor electronic cable made of 22AWG (7x30) tinned c...
- 1047A — The Belden 1047A is a 50-pair UL instrumentation cable featuring 16 AWG bare cop...
- 2143A — The Belden 2143A is a Category 6 premise horizontal cable designed for indoor an...
- 77147 — The Belden 77147 is a 2-conductor, 26 AWG tinned copper ECOCABLE featuring mPPE...
More Bulk Wire Cable
- 48334AS — The Belden 48334AS is a UL Type TC (1277) 3-conductor 18 AWG bare copper power a...
- 9903 — The Belden 9903 is an IEEE 802.3 Ethernet transceiver cable designed for 10BASE5...
- 9886 — The Belden 9886 is a direct-burial audio, control, and instrument cable featurin...
- 1152A — The Belden 1152A is a broadband coaxial cable (Series 6) featuring an 18 AWG sol...
- 6608HS — The 6608HS is a discontinued analog audio cable from Gepco (a Belden brand) desi...
- 1524AM — The Belden 1524AM is an RG11 type CATV video cable featuring a 14 AWG solid bare...
- 28156A — The Belden 28156A is a UL Type TC power and control cable with three 4 AWG bare...
- 8678 — The Belden 8678 is a 2-conductor electronic cable constructed with 10 AWG (19x23...
3308 FAQ
What is 3308?
3308 is a Bulk Wire Cable from Belden. The Belden 3308 is an 8-conductor, 28 AWG tinned copper communication and control cable with PVC insulation, overall tinned copper braid shield, and a black and red PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, suitable for industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for 600 V and operates within a temperature range of -55°C to +105°C.
Who manufactures 3308?
3308 is manufactured by Belden.
What is the marking code of 3308?
According to its datasheet, 3308 is marked "Alpha Wire -* P/N 3308 CE ROHS".
Where can I download the 3308 datasheet PDF?
The 3308 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 3308 specifications
Click to ask a quick question:
Parameters
| Conductor | 8 conductor, 28 AWG (7x36) tinned copper (TC) |
| Nom. Capacitance Cond-to-Cond | 29 pF/ft (95 pF/m) |
| Nom. Capacitance Cond-to-Other | 52 pF/ft (170 pF/m) |
| Nom. Inductance | 0.22 µH/ft (0.72 µH/m) |
| Nom Outer Shield DCR | 56 Ohm/1000ft (180 Ohm/km) |
| Operating Temperature | -55°C to +105°C |
| Overall Cable Diameter (Nominal) | 0.171 in (4.34 mm) |
| Voltage Rating | 600 V (MIL-SPEC) |