29502 Datasheet
Belden part 29502 is a flexible motor supply VFD cable with three 12 AWG (65x30) tinned copper conductors, XLPE insulation, and a 12 AWG tinned copper insulated ground. It features 100% Beldfoil tape plus 85% tinned copper braid shielding with a 12 AWG tinned copper ground/drain under a black PVC jacket, nominal overall diameter 0.630 in (16.0 mm). It is rated 600/1000V TC-ER 90°C dry/wet and is intended for variable frequency drives, AC motor and drive systems, and Class 1 Division 2 hazardous locations.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
29502 Key Specifications
- Max Current
- 30 Amps per Conductor at 30ºC
- Nominal Capacitance
- Cond-to-Cond 26 pF/ft (85 pF/m); Cond-to-Other (Conds + Shield) 47 pF/ft (150 pF/m)
- Voltage Rating
- 1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC), 1000 V (AWM I/II A/B)
- Temperature Rating
- UL 90°C Dry, 90°C Wet; Operating -40°C To +90°C
- Conductors / Ground
- 3 Conductor(s) 12 AWG 65x30 TC - Tinned Copper; Insulated Ground 1 12 AWG 65x30 TC - Tinned Copper
- Mechanical
- Overall Cable Diameter 0.630 in (16.0 mm); Max. Pull Tension 502 lbs (228 kg); Bend Radius Stationary 6.3 in (160 mm), Installation 7.6 in (190 mm)
- Nominal Conductor DCR
- 1.566 Ohm/1000ft (5.138 Ohm/km)
Characteristics (datasheet)
- Conductors / Ground
- 3 Conductor(s) 12 AWG 65x30 TC - Tinned Copper; Insulated Ground 1 12 AWG 65x30 TC - Tinned Copper
- Max Current
- 30 Amps per Conductor at 30ºC
- Nominal Conductor DCR
- 1.566 Ohm/1000ft (5.138 Ohm/km)
- Nominal Capacitance
- Cond-to-Cond 26 pF/ft (85 pF/m); Cond-to-Other (Conds + Shield) 47 pF/ft (150 pF/m)
- Voltage Rating
- 1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC), 1000 V (AWM I/II A/B)
- Temperature Rating
- UL 90°C Dry, 90°C Wet; Operating -40°C To +90°C
- Mechanical
- Overall Cable Diameter 0.630 in (16.0 mm); Max. Pull Tension 502 lbs (228 kg); Bend Radius Stationary 6.3 in (160 mm), Installation 7.6 in (190 mm)
29502 Applications
- Variable Frequency Drives (VFD)
- AC Motor and Drive Systems
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 83045 — The Belden 83045 is a high-temperature plastic lead wire featuring a 28 AWG (7x3...
- 6148 — The Belden 6148 is a heavy-duty Teck90 600V cable featuring 50 bare copper condu...
- 6017C — The Belden 6017C is a shielded communication and control cable consisting of 12...
- 21672 — The Belden 21672 is a CSA Type TC-CIC 600 V tray cable with three 2/0 AWG bare c...
- 7895A — The Belden 7895A is a DeviceBus® 2-pair communication cable featuring a tinned c...
- 78032 — The Belden 78032 is a 2-conductor 22 AWG tinned copper cable with modified polyp...
- 79250 — The Belden 79250 is a high-flexibility, shielded 2-conductor 24 AWG cable with m...
- 78219 — The Belden 78219 is a multi-pair ECOCABLE consisting of 9 pairs of 26 AWG strand...
More Bulk Wire Cable
- 78352 — The Belden 78352 is an ECOCABLE shielded multi-pair cable designed for data, com...
- 7411W — The Belden 7411W is a high-flexibility 'MachFlex' cable featuring three 18AWG ba...
- 5543 — The 5543 (Belden) is an XTRAGUARD 1 shielded multi-conductor cable featuring thr...
- 6829 — The Belden 6829 is a single-conductor hook-up wire constructed with 14 AWG bare...
- 1855 — The Belden 1855 is a single-conductor hook-up wire with a 22 AWG (7/30) tinned c...
- 25464 — Belden part 25464 is an XTRAGUARD 2, 4-conductor, 20 AWG (7x28 stranded tinned c...
- 1410R — The Belden 1410R is an audio snake cable designed for multi-channel interconnect...
- 87603 — The Belden 87603 is an XTRAGUARD FLEX 3-conductor 12 AWG bare copper cable with...
29502 FAQ
What is 29502?
29502 is a Bulk Wire Cable from Belden. Belden part 29502 is a flexible motor supply VFD cable with three 12 AWG (65x30) tinned copper conductors, XLPE insulation, and a 12 AWG tinned copper insulated ground. It features 100% Beldfoil tape plus 85% tinned copper braid shielding with a 12 AWG tinned copper ground/drain under a black PVC jacket, nominal overall diameter 0.630 in (16.0 mm). It is rated 600/1000V TC-ER 90°C dry/wet and is intended for variable frequency drives, AC motor and drive systems, and Class 1 Division 2 hazardous locations.
Who manufactures 29502?
29502 is manufactured by Belden.
Where can I download the 29502 datasheet PDF?
The 29502 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 29502 specifications
Click to ask a quick question:
Parameters
| Conductors / Ground | 3 Conductor(s) 12 AWG 65x30 TC - Tinned Copper; Insulated Ground 1 12 AWG 65x30 TC - Tinned Copper |
| Max Current | 30 Amps per Conductor at 30ºC |
| Mechanical | Overall Cable Diameter 0.630 in (16.0 mm); Max. Pull Tension 502 lbs (228 kg); Bend Radius Stationary 6.3 in (160 mm), Installation 7.6 in (190 mm) |
| Nominal Capacitance | Cond-to-Cond 26 pF/ft (85 pF/m); Cond-to-Other (Conds + Shield) 47 pF/ft (150 pF/m) |
| Nominal Conductor DCR | 1.566 Ohm/1000ft (5.138 Ohm/km) |
| Temperature Rating | UL 90°C Dry, 90°C Wet; Operating -40°C To +90°C |
| Voltage Rating | 1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC), 1000 V (AWM I/II A/B) |