29502 Datasheet

BeldenBulk Wire Cable

Belden part 29502 is a flexible motor supply VFD cable with three 12 AWG (65x30) tinned copper conductors, XLPE insulation, and a 12 AWG tinned copper insulated ground. It features 100% Beldfoil tape plus 85% tinned copper braid shielding with a 12 AWG tinned copper ground/drain under a black PVC jacket, nominal overall diameter 0.630 in (16.0 mm). It is rated 600/1000V TC-ER 90°C dry/wet and is intended for variable frequency drives, AC motor and drive systems, and Class 1 Division 2 hazardous locations.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

29502 Key Specifications

Max Current
30 Amps per Conductor at 30ºC
Nominal Capacitance
Cond-to-Cond 26 pF/ft (85 pF/m); Cond-to-Other (Conds + Shield) 47 pF/ft (150 pF/m)
Voltage Rating
1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC), 1000 V (AWM I/II A/B)
Temperature Rating
UL 90°C Dry, 90°C Wet; Operating -40°C To +90°C
Conductors / Ground
3 Conductor(s) 12 AWG 65x30 TC - Tinned Copper; Insulated Ground 1 12 AWG 65x30 TC - Tinned Copper
Mechanical
Overall Cable Diameter 0.630 in (16.0 mm); Max. Pull Tension 502 lbs (228 kg); Bend Radius Stationary 6.3 in (160 mm), Installation 7.6 in (190 mm)
Nominal Conductor DCR
1.566 Ohm/1000ft (5.138 Ohm/km)

Characteristics (datasheet)

Conductors / Ground
3 Conductor(s) 12 AWG 65x30 TC - Tinned Copper; Insulated Ground 1 12 AWG 65x30 TC - Tinned Copper
Max Current
30 Amps per Conductor at 30ºC
Nominal Conductor DCR
1.566 Ohm/1000ft (5.138 Ohm/km)
Nominal Capacitance
Cond-to-Cond 26 pF/ft (85 pF/m); Cond-to-Other (Conds + Shield) 47 pF/ft (150 pF/m)
Voltage Rating
1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC), 1000 V (AWM I/II A/B)
Temperature Rating
UL 90°C Dry, 90°C Wet; Operating -40°C To +90°C
Mechanical
Overall Cable Diameter 0.630 in (16.0 mm); Max. Pull Tension 502 lbs (228 kg); Bend Radius Stationary 6.3 in (160 mm), Installation 7.6 in (190 mm)

29502 Applications

  • Variable Frequency Drives (VFD)
  • AC Motor and Drive Systems
  • Class 1 Division 2 Hazardous Locations

Other Belden parts

  • 83045 — The Belden 83045 is a high-temperature plastic lead wire featuring a 28 AWG (7x3...
  • 6148 — The Belden 6148 is a heavy-duty Teck90 600V cable featuring 50 bare copper condu...
  • 6017C — The Belden 6017C is a shielded communication and control cable consisting of 12...
  • 21672 — The Belden 21672 is a CSA Type TC-CIC 600 V tray cable with three 2/0 AWG bare c...
  • 7895A — The Belden 7895A is a DeviceBus® 2-pair communication cable featuring a tinned c...
  • 78032 — The Belden 78032 is a 2-conductor 22 AWG tinned copper cable with modified polyp...
  • 79250 — The Belden 79250 is a high-flexibility, shielded 2-conductor 24 AWG cable with m...
  • 78219 — The Belden 78219 is a multi-pair ECOCABLE consisting of 9 pairs of 26 AWG strand...

More Bulk Wire Cable

  • 78352 — The Belden 78352 is an ECOCABLE shielded multi-pair cable designed for data, com...
  • 7411W — The Belden 7411W is a high-flexibility 'MachFlex' cable featuring three 18AWG ba...
  • 5543 — The 5543 (Belden) is an XTRAGUARD 1 shielded multi-conductor cable featuring thr...
  • 6829 — The Belden 6829 is a single-conductor hook-up wire constructed with 14 AWG bare...
  • 1855 — The Belden 1855 is a single-conductor hook-up wire with a 22 AWG (7/30) tinned c...
  • 25464 — Belden part 25464 is an XTRAGUARD 2, 4-conductor, 20 AWG (7x28 stranded tinned c...
  • 1410R — The Belden 1410R is an audio snake cable designed for multi-channel interconnect...
  • 87603 — The Belden 87603 is an XTRAGUARD FLEX 3-conductor 12 AWG bare copper cable with...

29502 FAQ

What is 29502?

29502 is a Bulk Wire Cable from Belden. Belden part 29502 is a flexible motor supply VFD cable with three 12 AWG (65x30) tinned copper conductors, XLPE insulation, and a 12 AWG tinned copper insulated ground. It features 100% Beldfoil tape plus 85% tinned copper braid shielding with a 12 AWG tinned copper ground/drain under a black PVC jacket, nominal overall diameter 0.630 in (16.0 mm). It is rated 600/1000V TC-ER 90°C dry/wet and is intended for variable frequency drives, AC motor and drive systems, and Class 1 Division 2 hazardous locations.

Who manufactures 29502?

29502 is manufactured by Belden.

Where can I download the 29502 datasheet PDF?

The 29502 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 29502 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductors / Ground3 Conductor(s) 12 AWG 65x30 TC - Tinned Copper; Insulated Ground 1 12 AWG 65x30 TC - Tinned Copper
Max Current30 Amps per Conductor at 30ºC
MechanicalOverall Cable Diameter 0.630 in (16.0 mm); Max. Pull Tension 502 lbs (228 kg); Bend Radius Stationary 6.3 in (160 mm), Installation 7.6 in (190 mm)
Nominal CapacitanceCond-to-Cond 26 pF/ft (85 pF/m); Cond-to-Other (Conds + Shield) 47 pF/ft (150 pF/m)
Nominal Conductor DCR1.566 Ohm/1000ft (5.138 Ohm/km)
Temperature RatingUL 90°C Dry, 90°C Wet; Operating -40°C To +90°C
Voltage Rating1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC), 1000 V (AWM I/II A/B)