The Belden 6362 is a communication and control cable consisting of 2 pairs of 24 AWG tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. Key electrical characteristics include a nominal characteristic impedance of 75 Ohm, a cond-to-cond capacitance of 30 pF/ft, and a UL voltage rating of 300 V.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
6362 Key Specifications
- Nom. Capacitance Cond-to-Cond
- 30 pF/ft (98 pF/m)
- Nom. Capacitance Cond-to-Other (Conds + Shield)
- 500 pF/ft (1600 pF/m)
- UL Voltage Rating
- 300 V (CMG, CM, AWM 2464)
- UL Temperature / Operating Temperature
- 80°C / -20°C To +80°C
- Bend Radius Stationary Min.
- 2.3 in (58 mm)
- Conductor
- 2 Pair 24 AWG 7x32 TC - Tinned Copper
- Insulation Material
- SR-PVC - Polyvinyl Chloride (Semi-Rigid), Nom. Thickness 0.010 in (0.25 mm)
- Max. Pull Tension
- 103 lbs (46.7 kg)
Characteristics (datasheet)
- Conductor
- 2 Pair 24 AWG 7x32 TC - Tinned Copper
- Insulation Material
- SR-PVC - Polyvinyl Chloride (Semi-Rigid), Nom. Thickness 0.010 in (0.25 mm)
- Outer Shield
- Tape Bi-Laminate (Alum+Poly) 100% coverage; Braid Tinned Copper (TC) 65% coverage
- Outer Jacket
- PVC - Polyvinyl Chloride, Nom. Thickness 0.032 in (0.81 mm)
- Nom. Capacitance Cond-to-Cond
- 30 pF/ft (98 pF/m)
- Nom. Capacitance Cond-to-Other (Conds + Shield)
- 500 pF/ft (1600 pF/m)
- Nom. Characteristic Impedence
- 75 Ohm
- Nom Outer Shield DCR
- 57 Ohm/1000ft (190 Ohm/km)
- UL Voltage Rating
- 300 V (CMG, CM, AWM 2464)
- UL Temperature / Operating Temperature
- 80°C / -20°C To +80°C
- Overall Cable Diameter (Nominal)
- 0.234 in (5.94 mm)
- Max. Pull Tension
- 103 lbs (46.7 kg)
- Bend Radius Stationary Min.
- 2.3 in (58 mm)
6362 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 5688 — The Belden 5688 is a 10-conductor 26 AWG tinned copper cable with semi-rigid PVC...
- 78002 — The Belden 78002 is a 2-conductor 28 AWG tinned copper ECOCABLE with modified po...
- 934073100 — HIRSCHMANN TEST AND MEASUREMENT 934073100 Test Lead, 4mm Banana Plug to 4mm...
- 8810 — The Belden 8810 is an unshielded, 2-conductor 10 AWG speaker cable constructed w...
- 29021 — The Belden 29021 is a Canadian Instrumentation Cable (TC-ACIC) rated for 600 V p...
- 5453C — The Belden 5453C is an XTRAGUARD 1 shielded multi-conductor cable featuring 3 pa...
- 8254 — The Belden 8254 is a 93Ω RG-62/U type coaxial cable featuring a 22 AWG solid bar...
- 9463 — The Belden 9463 Blue Hose® is a 1-pair 20 AWG tinned copper twinax cable with po...
More Bulk Wire Cable
- 5263C — The Belden 5263C is a multi-conductor signal cable featuring three 24 AWG tinned...
- 5313C — The Belden 5313C is a 15-conductor, 22 AWG tinned copper XTRAGUARD 1 shielded ca...
- 6024C — The Belden 6024C is a shielded communication and control cable featuring 6 pairs...
- 9290 — The Belden 9290 is an RG6 coaxial cable designed primarily for analog video tran...
- 6624 — The Belden 6624 is a 4-conductor, 24 AWG tinned copper control cable with irradi...
- 83008 — Belden 83008 is a high-temperature lead wire constructed with one 20 AWG (7x28)...
- 5036C — The Belden 5036C is an XTRAGUARD 1 multi-conductor cable featuring 6 pairs of 18...
- 78450 — The Belden 78450 is an ECOCABLE consisting of 25 pairs of 20 AWG tinned copper c...
6362 FAQ
What is 6362?
6362 is a Bulk Wire Cable from Belden. The Belden 6362 is a communication and control cable consisting of 2 pairs of 24 AWG tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. Key electrical characteristics include a nominal characteristic impedance of 75 Ohm, a cond-to-cond capacitance of 30 pF/ft, and a UL voltage rating of 300 V.
Who manufactures 6362?
6362 is manufactured by Belden.
Where can I download the 6362 datasheet PDF?
The 6362 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 6362 specifications
Click to ask a quick question:
Parameters
| Bend Radius Stationary Min. | 2.3 in (58 mm) |
| Conductor | 2 Pair 24 AWG 7x32 TC - Tinned Copper |
| Insulation Material | SR-PVC - Polyvinyl Chloride (Semi-Rigid), Nom. Thickness 0.010 in (0.25 mm) |
| Max. Pull Tension | 103 lbs (46.7 kg) |
| Nom. Capacitance Cond-to-Cond | 30 pF/ft (98 pF/m) |
| Nom. Capacitance Cond-to-Other (Conds + Shield) | 500 pF/ft (1600 pF/m) |
| Nom. Characteristic Impedence | 75 Ohm |
| Nom Outer Shield DCR | 57 Ohm/1000ft (190 Ohm/km) |
| Outer Jacket | PVC - Polyvinyl Chloride, Nom. Thickness 0.032 in (0.81 mm) |
| Outer Shield | Tape Bi-Laminate (Alum+Poly) 100% coverage; Braid Tinned Copper (TC) 65% coverage |
| Overall Cable Diameter (Nominal) | 0.234 in (5.94 mm) |
| UL Temperature / Operating Temperature | 80°C / -20°C To +80°C |
| UL Voltage Rating | 300 V (CMG, CM, AWM 2464) |