30804 Datasheet
The Belden 30804 is a 4 AWG (105x24) stranded tinned copper lead wire with silicone rubber insulation and a lacquered glass braid outer jacket, rated AWM 3125 and CSA SEW-2 at 600 V. It is designed for Class 130(B), 155(F) or 180(H) insulation systems, internal wiring of lighting fixtures and appliances, and high temperature applications, with an operating temperature range of -70 °C to +200 °C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
30804 Key Specifications
- Maximum Current
- 200 Amps per conductor at 30ºC
- Voltage Rating
- 600 V (AWM 3125); 600 V (CSA SEW-2)
- Operating Temperature / UL Temperature
- -70 °C to +200 °C (UL 200 °C)
- Bend Radius (Stationary / Installation)
- 4.24 in (108 mm)
- Bulk Cable Weight
- 189 lbs/1000ft
- Conductor
- 4 AWG, 105x24 stranded tinned copper
- Insulation Diameter
- 0.390 in (9.91 mm) nominal
- Insulation Material / Thickness
- Silicone rubber, 0.063 in (1.6 mm) nominal
Characteristics (datasheet)
- Conductor
- 4 AWG, 105x24 stranded tinned copper
- Insulation Material / Thickness
- Silicone rubber, 0.063 in (1.6 mm) nominal
- Insulation Diameter
- 0.390 in (9.91 mm) nominal
- Outer Jacket / Overall Diameter
- Lacquered glass braid covering, 0.424 in (10.8 mm)
- Nominal Conductor DCR
- 0.279 Ohm/1000ft
- Maximum Current
- 200 Amps per conductor at 30ºC
- Voltage Rating
- 600 V (AWM 3125); 600 V (CSA SEW-2)
- Operating Temperature / UL Temperature
- -70 °C to +200 °C (UL 200 °C)
- Maximum Pull Tension
- 532 lbs (241 kg)
- Bulk Cable Weight
- 189 lbs/1000ft
- Bend Radius (Stationary / Installation)
- 4.24 in (108 mm)
30804 Applications
- Class 130(B), 155(F) or 180(H) insulation systems
- Internal wiring of lighting fixtures and appliances
- High temperature applications
Other Belden parts
- 9807 — The Belden 9807 is a computer EIA RS-232/422 cable featuring five pairs of 28 AW...
- 38010 — The Belden 38010 is a UL Type PV wire with 10 AWG tinned copper conductors (105x...
- 934073100 — HIRSCHMANN TEST AND MEASUREMENT 934073100 Test Lead, 4mm Banana Plug to 4mm...
- 5404 — The Belden 5404 is a 4-conductor, 22 AWG tinned copper control cable with PVC in...
- 3520 — The Belden 3520 is a 20-conductor hook-up wire cable featuring 22 AWG (7/30) tin...
- 86406CY — The Belden 86406CY is a continuous flex data cable featuring 6 pairs of 28 AWG s...
- 4101FE — The Belden 4101FE is a security and commercial audio cable featuring three 14 AW...
- 3112A — The Belden 3112A is a Type KX thermocouple cable containing a single pair of 20...
More Bulk Wire Cable
- 23529D — The Belden 23529D is a Canadian TC-ACIC instrumentation cable rated 300 V, built...
- 9808 — The Belden 9808 is a computer EIA RS-232/RS-422 cable featuring 7 pairs of 28 AW...
- 21667 — The Belden 21667 is a CSA Type TC tray cable rated 600 V, containing four 1 AWG...
- 28139A — The Belden 28139A is a UL Type TC (1277) 3-conductor power and control cable wit...
- 83905 — The Belden 83905 is a Type K thermocouple pair cable featuring 20 AWG solid Chro...
- 3247 — The Belden 3247 is a 3-conductor 16 AWG tinned copper communication and control...
- 9272 — The Belden 9272 is a 78 Ohm twinaxial cable constructed with 20 AWG stranded tin...
- 9853C — The 9853C is a 3-pair 20 AWG tinned copper coaxial cable with foam HDPE insulati...
30804 FAQ
What is 30804?
30804 is a Bulk Wire Cable from Belden. The Belden 30804 is a 4 AWG (105x24) stranded tinned copper lead wire with silicone rubber insulation and a lacquered glass braid outer jacket, rated AWM 3125 and CSA SEW-2 at 600 V. It is designed for Class 130(B), 155(F) or 180(H) insulation systems, internal wiring of lighting fixtures and appliances, and high temperature applications, with an operating temperature range of -70 °C to +200 °C.
Who manufactures 30804?
30804 is manufactured by Belden.
Where can I download the 30804 datasheet PDF?
The 30804 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 30804 specifications
Click to ask a quick question:
Parameters
| Bend Radius (Stationary / Installation) | 4.24 in (108 mm) |
| Bulk Cable Weight | 189 lbs/1000ft |
| Conductor | 4 AWG, 105x24 stranded tinned copper |
| Insulation Diameter | 0.390 in (9.91 mm) nominal |
| Insulation Material / Thickness | Silicone rubber, 0.063 in (1.6 mm) nominal |
| Maximum Current | 200 Amps per conductor at 30ºC |
| Maximum Pull Tension | 532 lbs (241 kg) |
| Nominal Conductor DCR | 0.279 Ohm/1000ft |
| Operating Temperature / UL Temperature | -70 °C to +200 °C (UL 200 °C) |
| Outer Jacket / Overall Diameter | Lacquered glass braid covering, 0.424 in (10.8 mm) |
| Voltage Rating | 600 V (AWM 3125); 600 V (CSA SEW-2) |