1041A Datasheet
The Belden 1041A is an 8-pair, 16 AWG bare copper instrumentation cable with PVC-nylon insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF voltage levels, supporting a maximum current of 9 Amps per conductor and an operating temperature range of -30°C to 90°C dry/wet. This cable is suitable for industrial control, raceways, digital control, instruments, and distributed control systems (DCS) or programmable logic controllers (PLC).
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1041A Key Specifications
- Max. Current
- 9 Amps per conductor @ 30°C
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- UL Temperature / Operating Temperature
- 90°C Dry, 90°C Wet / -30°C to 90°C Dry/Wet
- Bulk Cable Weight
- 323 lbs/1000ft
- Conductor
- 8 Pair(s), 16 AWG 7x24 BC - Bare Copper
- Max. Pull Tension
- 629 lbs (285 kg)
- Min. Bend Radius (Stationary / Installation)
- 8.7 in (220 mm)
- Nom. Conductor DCR
- 4.2 Ohm/1000ft
Characteristics (datasheet)
- Conductor
- 8 Pair(s), 16 AWG 7x24 BC - Bare Copper
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Max. Current
- 9 Amps per conductor @ 30°C
- Nom. Conductor DCR
- 4.2 Ohm/1000ft
- Nom. Inner Shield DCR
- 5.49 Ohm/1000ft (18.0 Ohm/km)
- Nom Outer Shield DCR
- 3.14 Ohm/1000ft (10.3 Ohm/km)
- UL Temperature / Operating Temperature
- 90°C Dry, 90°C Wet / -30°C to 90°C Dry/Wet
- Overall Cable Diameter (Nominal)
- 0.725 in (18.4 mm)
- Min. Bend Radius (Stationary / Installation)
- 8.7 in (220 mm)
- Max. Pull Tension
- 629 lbs (285 kg)
- Bulk Cable Weight
- 323 lbs/1000ft
1041A Applications
- Industrial control
- Raceways, cable trays, and ducts
- Digital control
- Instruments (4-20mA, 0-10V)
- Low voltage digital control (24V)
- Encoders and control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids, valves, actuators, and positioners
Other Belden parts
- 6393 — The Belden 6393 is a 5-pair, 28 AWG tinned copper conductor communication and co...
- 24513D — The Belden 24513D is a Canadian ACIC 600 V instrumentation cable with 4 pairs of...
- 1294C — The Belden 1294C is a 4-conductor, 22 AWG tinned copper communication and contro...
- 1102 — The Belden 1102 is a communication and control cable consisting of four 32 AWG t...
- 1067 — The Belden 1067 is a communication and control cable consisting of seven 16 AWG...
- 35110 — The Belden 35110 is an XTRAGUARD 3 multi-conductor cable with 10 conductors of 2...
- 3612 — The Belden 3612 is a Category 6+ premium premise horizontal cable featuring 4 pa...
- 1505A — The Belden 1505A is a 75 Ohm SDI coaxial cable of RG-59 type, built with a 20 AW...
More Bulk Wire Cable
- 77203 — The Belden 77203 is an ECOCABLE featuring 12 conductors of 24 AWG (7/32) tinned...
- 76504TS — The Belden 76504TS is a high-flexibility multi-conductor cable (MachFlex) contai...
- 77605W — The Belden 77605W is a high-flex, 5-conductor plus ground (5+G) cable with 16 AW...
- 55114 — The Belden 55114 is an XTRAGUARD 5 multi-conductor cable featuring 4 conductors...
- 25172 — The Belden 25172 is an XTRAGUARD 2 cable with 2 conductors of 16 AWG (19x29) str...
- 3066A — The Belden 3066A is a UL-listed instrumentation cable consisting of 16 triads of...
- 80120 — The Belden 80120 ECOFLEX PUR cable is a flexible, zero-halogen, 2-conductor 20 A...
- 77013 — The Belden 77013 is a 3-conductor 20 AWG tinned copper cable with mPPE insulatio...
1041A FAQ
What is 1041A?
1041A is a Bulk Wire Cable from Belden. The Belden 1041A is an 8-pair, 16 AWG bare copper instrumentation cable with PVC-nylon insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF voltage levels, supporting a maximum current of 9 Amps per conductor and an operating temperature range of -30°C to 90°C dry/wet. This cable is suitable for industrial control, raceways, digital control, instruments, and distributed control systems (DCS) or programmable logic controllers (PLC).
Who manufactures 1041A?
1041A is manufactured by Belden.
Where can I download the 1041A datasheet PDF?
The 1041A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1041A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 323 lbs/1000ft |
| Conductor | 8 Pair(s), 16 AWG 7x24 BC - Bare Copper |
| Max. Current | 9 Amps per conductor @ 30°C |
| Max. Pull Tension | 629 lbs (285 kg) |
| Min. Bend Radius (Stationary / Installation) | 8.7 in (220 mm) |
| Nom. Conductor DCR | 4.2 Ohm/1000ft |
| Nom. Inner Shield DCR | 5.49 Ohm/1000ft (18.0 Ohm/km) |
| Nom Outer Shield DCR | 3.14 Ohm/1000ft (10.3 Ohm/km) |
| Overall Cable Diameter (Nominal) | 0.725 in (18.4 mm) |
| UL Temperature / Operating Temperature | 90°C Dry, 90°C Wet / -30°C to 90°C Dry/Wet |
| Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |