27140A Datasheet

BeldenBulk Wire Cable

Belden 27140A is a four-conductor UL Type TC power and control cable built with 10 AWG (7x18) bare copper conductors, PVC-nylon insulation, and a black PVC jacket. It is rated for 600 V and 90 °C dry / 75 °C wet operation, with a wet/dry operating range of -30 °C to 90 °C. The cable is approved for indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial use, including Class 1 Division 2 hazardous locations.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

27140A Key Specifications

Max current
32 Amps per conductor at 30 °C
Voltage rating
600 V
Temperature rating
90 °C dry, 75 °C wet; wet/dry -30 °C to 90 °C
Bend radius (stationary/installation)
1.956 in (49.68 mm) / 2.445 in
Conductor configuration
4 conductors, 10 AWG, 7x18 stranding, bare copper
Conductor DCR
1.06 Ohm/1000ft nominal
Insulation diameter
0.164 in (4.17 mm) nominal
Insulation material/thickness
PVC/Nylon, 0.024 in (0.61 mm) nominal thickness

Characteristics (datasheet)

Conductor configuration
4 conductors, 10 AWG, 7x18 stranding, bare copper
Insulation material/thickness
PVC/Nylon, 0.024 in (0.61 mm) nominal thickness
Insulation diameter
0.164 in (4.17 mm) nominal
Jacket material/thickness
Black PVC, 0.047 in (1.2 mm) nominal thickness
Overall cable diameter
0.489 in nominal
Conductor DCR
1.06 Ohm/1000ft nominal
Max current
32 Amps per conductor at 30 °C
Voltage rating
600 V
Temperature rating
90 °C dry, 75 °C wet; wet/dry -30 °C to 90 °C
Bend radius (stationary/installation)
1.956 in (49.68 mm) / 2.445 in
Max pull tension / weight
542 lbs (246 kg) / 197 lbs/1000ft

27140A Applications

  • Power and Control Applications up to 600V
  • Class 1 Division 2 Hazardous Locations

Other Belden parts

  • 2401C — The Belden 2401C is a 2-conductor, 22 AWG tinned copper communication and contro...
  • 5875 — The Belden 5875 is a single-conductor, 22 AWG silver-plated copper hook-up wire...
  • 5468C — The 5468C is an 8-conductor, 20 AWG tinned copper shielded cable with PVC insula...
  • 70267PU — The Belden 70267PU is a PUR distribution box cable featuring 8 x 0.50 mm² and 3...
  • 3066A — The Belden 3066A is a UL-listed instrumentation cable consisting of 16 triads of...
  • 5677 — The Belden 5677 is a shielded, 6-conductor 26 AWG tinned copper cable with semi-...
  • 1561 — The Belden 1561 is a single-conductor, 22 AWG solid tinned copper hook-up wire w...
  • 1280 — The Belden 1280 is a heavy-duty power and control cable rated at 1000V, featurin...

More Bulk Wire Cable

  • 25452 — The Belden 25452 is an XTRAGUARD 2 cable consisting of 2 pairs of 20 AWG (7x28)...
  • 70034 — The Belden 70034 is a discontinued 12-pair analog audio cable featuring 26AWG ox...
  • 9248 — The Belden 9248 is a 75 Ohm RG-6 analog video coaxial cable featuring an 18 AWG...
  • 9260 — The Belden 9260 is a 6-conductor 20 AWG tinned copper cable with PVC insulation,...
  • 35416 — Belden 35416 is a 16 AWG (26x30) tinned copper lead wire with XLPO thermoset ins...
  • 8167 — The Belden 8167 is a computer EIA RS-232/422 digital audio cable containing 7 in...
  • 58119 — The Belden 58119 is a plenum-rated communication and control cable featuring nin...
  • 28160A — The Belden 28160A is a UL Type TC power and control cable consisting of four 2 A...

27140A FAQ

What is 27140A?

27140A is a Bulk Wire Cable from Belden. Belden 27140A is a four-conductor UL Type TC power and control cable built with 10 AWG (7x18) bare copper conductors, PVC-nylon insulation, and a black PVC jacket. It is rated for 600 V and 90 °C dry / 75 °C wet operation, with a wet/dry operating range of -30 °C to 90 °C. The cable is approved for indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial use, including Class 1 Division 2 hazardous locations.

Who manufactures 27140A?

27140A is manufactured by Belden.

Where can I download the 27140A datasheet PDF?

The 27140A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 27140A specifications

AI Powered

Click to ask a quick question:

Parameters

Bend radius (stationary/installation)1.956 in (49.68 mm) / 2.445 in
Conductor configuration4 conductors, 10 AWG, 7x18 stranding, bare copper
Conductor DCR1.06 Ohm/1000ft nominal
Insulation diameter0.164 in (4.17 mm) nominal
Insulation material/thicknessPVC/Nylon, 0.024 in (0.61 mm) nominal thickness
Jacket material/thicknessBlack PVC, 0.047 in (1.2 mm) nominal thickness
Max current32 Amps per conductor at 30 °C
Max pull tension / weight542 lbs (246 kg) / 197 lbs/1000ft
Overall cable diameter0.489 in nominal
Temperature rating90 °C dry, 75 °C wet; wet/dry -30 °C to 90 °C
Voltage rating600 V