3066A Datasheet

BeldenBulk Wire Cable

The Belden 3066A is a UL-listed instrumentation cable consisting of 16 triads of 18 AWG stranded bare copper conductors with color-coded PVC-nylon insulation, wrapped in individual and overall aluminum-polyester shields, and encased in a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, with a temperature rating of 75°C dry and 90°C wet, and is suitable for outdoor, sunlight-resistant, and direct burial environments. This cable is designed for use in industrial control systems, raceways, digital instruments, DCS, PLCs, solenoids, valves, and actuators.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

3066A Key Specifications

Max. Current
5 Amps per Conductor at 25ºC
UL Voltage Rating
600 V RMS, 150 V RMS (NPLF)
Voltage Rating
600 V RMS, 150 V RMS (NPLF)
Temperature Rating
75°C Dry, 90°C Wet
UL Temperature
75°C Dry, 90°C Wet
Bulk Cable Weight
608 lbs/1000ft (905 kg/km)
Construction
16 Triad, 18 AWG (7x26) Bare Copper, PVC-Nylon Insulation, Individual & Overall Beldfoil Shield, Black PVC Outer Jacket
Max. Pull Tension
1322 lbs (599.6 kg)

Characteristics (datasheet)

Construction
16 Triad, 18 AWG (7x26) Bare Copper, PVC-Nylon Insulation, Individual & Overall Beldfoil Shield, Black PVC Outer Jacket
Nom. Conductor DCR
5.86 Ohm/1000ft (19.2 Ohm/km)
Nom. Inner Shield DCR
7.11 Ohm/1000ft (23.3 Ohm/km)
Nom Outer Shield DCR
5.52 Ohm/1000ft (18.1 Ohm/km)
Voltage Rating
600 V RMS, 150 V RMS (NPLF)
Temperature Rating
75°C Dry, 90°C Wet
Bulk Cable Weight
608 lbs/1000ft (905 kg/km)
Outer Jacket Diameter
1.041 in nominal

Absolute Maximum Ratings

UL Voltage Rating
600 V RMS, 150 V RMS (NPLF)
Max. Current
5 Amps per Conductor at 25ºC
UL Temperature
75°C Dry, 90°C Wet
Max. Pull Tension
1322 lbs (599.6 kg)

3066A Applications

  • Industrial Control
  • Raceways, cable trays and ducts
  • Digital Control
  • Instruments (4-20ma, 0-10v)
  • Low voltage digital control (24v)
  • Encoders
  • Control circuits
  • Distributed control system (DCS)
  • Programmable logic controller (PLC)
  • Solenoids, Valves, Actuators, Positioners

Other Belden parts

  • 1700A — The Belden 1700A is a Category 5E+ Premise Horizontal Cable featuring 4 bonded p...
  • 50980 — The Belden 50980 is a highly flexible, unshielded speaker cable featuring four 4...
  • 1333A — The Belden 1333A is a high-performance 24-pair 18AWG tinned copper fieldbus cabl...
  • 2115A — The Belden 2115A is a 20-pair fieldbus cable with 16 AWG tinned copper conductor...
  • 29510 — Belden 29510 is a flexible 600 V TC-ER / 1000 V AWM motor supply cable built for...
  • 55116 — The Belden 55116 is an XTRAGUARD 5, 6-conductor 24 AWG tinned copper cable with...
  • 79203 — The Belden 79203 is a flexible 4-conductor, 20 AWG tinned copper cable with mPPE...
  • 5320C — The Belden 5320C is a highly shielded, multi-conductor cable featuring five 20 A...

More Bulk Wire Cable

  • 70260PU — The 70260PU is a PUR distribution box cable featuring 12 conductors of 0.50 mm²...
  • 8213 — Belden 8213 is an RG11 analog video coaxial cable featuring a 14 AWG solid bare...
  • 8630MN — The 8630MN is a SpaceMaker™ multi-conductor cable featuring nine 16AWG tinned co...
  • 45463 — Belden part 45463 is an XTRAGUARD 4 multi-conductor cable with 3 conductors of 2...
  • 5012C — The Belden 5012C is a 2-conductor, 24 AWG tinned copper cable with semi-rigid PV...
  • 6158 — The Belden 6158 is a heavy-duty Teck90 1000V cable featuring 2+G bare copper con...
  • 79121 — The Belden 79121 is a flexible, shielded 2-conductor 14 AWG tinned copper cable...
  • 21670 — Belden part 21670 is a CSA Type TC-CIC 600 V tray cable with four 1/0 AWG bare c...

3066A FAQ

What is 3066A?

3066A is a Bulk Wire Cable from Belden. The Belden 3066A is a UL-listed instrumentation cable consisting of 16 triads of 18 AWG stranded bare copper conductors with color-coded PVC-nylon insulation, wrapped in individual and overall aluminum-polyester shields, and encased in a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, with a temperature rating of 75°C dry and 90°C wet, and is suitable for outdoor, sunlight-resistant, and direct burial environments. This cable is designed for use in industrial control systems, raceways, digital instruments, DCS, PLCs, solenoids, valves, and actuators.

Who manufactures 3066A?

3066A is manufactured by Belden.

Where can I download the 3066A datasheet PDF?

The 3066A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 3066A specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk Cable Weight608 lbs/1000ft (905 kg/km)
Construction16 Triad, 18 AWG (7x26) Bare Copper, PVC-Nylon Insulation, Individual & Overall Beldfoil Shield, Black PVC Outer Jacket
Max. Current5 Amps per Conductor at 25ºC
Max. Pull Tension1322 lbs (599.6 kg)
Nom. Conductor DCR5.86 Ohm/1000ft (19.2 Ohm/km)
Nom. Inner Shield DCR7.11 Ohm/1000ft (23.3 Ohm/km)
Nom Outer Shield DCR5.52 Ohm/1000ft (18.1 Ohm/km)
Outer Jacket Diameter1.041 in nominal
Temperature Rating75°C Dry, 90°C Wet
UL Temperature75°C Dry, 90°C Wet
UL Voltage Rating600 V RMS, 150 V RMS (NPLF)
Voltage Rating600 V RMS, 150 V RMS (NPLF)