50001L Datasheet
The Belden 50001L is an RS-485 fire resistant cable with one pair of 22 AWG stranded tinned copper conductors. It uses mica glass tape and electron-beam cross-linked polyethylene (XLPE) insulation, an overall foil plus tinned copper braid shield, and a low smoke zero halogen (LSZH) jacket, and is rated to IEC 60331-23 fire resistance with ABS approval. It is intended for RS 232/422/485, CANBUS, and MODBUS communication in machine control, SCADA, emergency evacuation/shutdown, building automation, offshore, oil & gas, and railway applications.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
50001L Key Specifications
- Nom. Capacitance Cond-to-Cond
- 46 pF/m (14 pF/ft)
- Voltage Rating
- 300 V
- Operating Temperature
- -40°C To +90°C
- Bulk Cable Weight
- 94.1 kg/km (63.2 lbs/1000ft)
- Conductor
- 22 AWG Stranded TC - Tinned Copper
- Nom. Characteristic Impedance
- 120 Ohm
- Nom. Conductor DCR
- 59.4 Ohm/km (18.1 Ohm/1000ft)
- Overall Cable Diameter (Nominal)
- 8.5 mm (0.33 in)
Characteristics (datasheet)
- Conductor
- 22 AWG Stranded TC - Tinned Copper
- Overall Cable Diameter (Nominal)
- 8.5 mm (0.33 in)
- Nom. Conductor DCR
- 59.4 Ohm/km (18.1 Ohm/1000ft)
- Nom. Characteristic Impedance
- 120 Ohm
- Nom. Capacitance Cond-to-Cond
- 46 pF/m (14 pF/ft)
- Voltage Rating
- 300 V
- Operating Temperature
- -40°C To +90°C
- Bulk Cable Weight
- 94.1 kg/km (63.2 lbs/1000ft)
50001L Applications
- motion oriented machine
- machine control networks
- temperature controllers
- control panels
- machine cutting tools
- auxiliary equipment
- SCADA communications
- emergency evacuation/shutdown systems
- building automation
- offshore
- railway applications
Other Belden parts
- 38010 — The Belden 38010 is a UL Type PV wire with 10 AWG tinned copper conductors (105x...
- 9806 — The Belden 9806 is a shielded, 4-pair, 28 AWG stranded tinned copper cable desig...
- 6378 — The Belden 6378 is a communication and control cable featuring 7 pairs of 22 AWG...
- 5475C — The Belden 5475C is a multi-pair communication and control cable consisting of 5...
- 5092C — The Belden 5092C is a 2-conductor, 24 AWG tinned copper shielded cable with semi...
- 32416 — Belden part 32416 is a 16 AWG stranded tinned copper lead wire with silicone rub...
- 1250 — The Belden 1250 is a 600V RW90 power and control cable featuring a 14 AWG bare c...
- 6547FE — The 6547FE is a plenum-rated (CMP) security and sound cable consisting of 9 pair...
More Bulk Wire Cable
- 9583 — The Belden 9583 is a 2-conductor, 12 AWG solid bare copper cable with PVC insula...
- 78132 — The part 78132 is a 2-conductor 22 AWG tinned copper ECOCABLE with modified poly...
- 1472A — The Belden 1472A is a UL-listed instrumentation cable designed for industrial co...
- 21638 — The Belden 21638 is a 40-conductor CSA Tray TC-CIC cable rated 600 V with 10 AWG...
- 45453 — Belden part 45453 is an XTRAGUARD 4 cable consisting of 3 pairs of 20 AWG (7x28)...
- 80035 — The Belden 80035 is a flexible, 5-conductor 18 AWG tinned copper cable with mPPE...
- 4308UE — The Belden 4308UE is a 10-conductor 18 AWG stranded bare copper security and com...
- 1600 — The Belden 1600 is a heavy-duty 600V, 2/0 AWG bare copper cable with PVC insulat...
50001L FAQ
What is 50001L?
50001L is a Bulk Wire Cable from Belden. The Belden 50001L is an RS-485 fire resistant cable with one pair of 22 AWG stranded tinned copper conductors. It uses mica glass tape and electron-beam cross-linked polyethylene (XLPE) insulation, an overall foil plus tinned copper braid shield, and a low smoke zero halogen (LSZH) jacket, and is rated to IEC 60331-23 fire resistance with ABS approval. It is intended for RS 232/422/485, CANBUS, and MODBUS communication in machine control, SCADA, emergency evacuation/shutdown, building automation, offshore, oil & gas, and railway applications.
Who manufactures 50001L?
50001L is manufactured by Belden.
Where can I download the 50001L datasheet PDF?
The 50001L datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 50001L specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 94.1 kg/km (63.2 lbs/1000ft) |
| Conductor | 22 AWG Stranded TC - Tinned Copper |
| Nom. Capacitance Cond-to-Cond | 46 pF/m (14 pF/ft) |
| Nom. Characteristic Impedance | 120 Ohm |
| Nom. Conductor DCR | 59.4 Ohm/km (18.1 Ohm/1000ft) |
| Operating Temperature | -40°C To +90°C |
| Overall Cable Diameter (Nominal) | 8.5 mm (0.33 in) |
| Voltage Rating | 300 V |