5198C Datasheet
The 5198C is an 8-conductor, 22 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and operates within a temperature range of -35°C to +105°C. It is designed for industrial control systems, instrumentation and control circuits, PLC and DCS systems, and sensor/encoder applications, supporting both analog and digital signals.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
5198C Key Specifications
- Nom. Capacitance Cond-to-Cond
- 35 pF/ft (110 pF/m)
- Nom. Inductance
- 0.18 µH/ft (0.59 µH/m)
- Voltage Rating
- 300 V (CMG, CM, AWM 2464, AWM 2517)
- Operating Temperature
- -35°C to +105°C
- Conductor
- 8 conductors, 22 AWG (7x30) TC - Tinned Copper
- Max. Pull Tension / Min. Bend Radius
- 82 lbs (37 kg) / 1.2 in (30 mm) stationary
- Nominal Outer Diameter
- 0.239 in (6.07 mm)
- Shield
- Overall Aluminum/Polyester shield (100% coverage) with 22 AWG TC drainwire
Characteristics (datasheet)
- Conductor
- 8 conductors, 22 AWG (7x30) TC - Tinned Copper
- Voltage Rating
- 300 V (CMG, CM, AWM 2464, AWM 2517)
- Operating Temperature
- -35°C to +105°C
- Nominal Outer Diameter
- 0.239 in (6.07 mm)
- Shield
- Overall Aluminum/Polyester shield (100% coverage) with 22 AWG TC drainwire
- Nom. Capacitance Cond-to-Cond
- 35 pF/ft (110 pF/m)
- Nom. Inductance
- 0.18 µH/ft (0.59 µH/m)
- Max. Pull Tension / Min. Bend Radius
- 82 lbs (37 kg) / 1.2 in (30 mm) stationary
5198C Applications
- Industrial control systems, raceways, cable trays, and ducts
- Instrumentation and control circuits
- Analog and digital signals (4–20 mA, 0–10 V)
- PLC and DCS systems
- Sensors, encoders, solenoids, valves, actuators, and positioners
Other Belden parts
- 45198 — The Belden 45198 is an XTRAGUARD 4 cable with 8 conductors of 22 AWG (7/30) tinn...
- 21672 — The Belden 21672 is a CSA Type TC-CIC 600 V tray cable with three 2/0 AWG bare c...
- 7770ELY — The Belden 7770ELY is a Category 7A enhanced premise horizontal cable (1600 MHz)...
- 77201 — The Belden 77201 is a 4-conductor, 24 AWG tinned copper ECOCABLE with mPPE insul...
- 82502 — The Belden 82502 is a plenum-rated, computer EIA RS-232 cable designed for indoo...
- 46381NH — The Belden 46381NH is a discontinued 2-conductor speaker cable with 2.5 mm² oxyg...
- 8077 — The Belden 8077 is a class 200 magnet wire consisting of a single 22 AWG solid b...
- 7817A — The Belden 7817A is a 12mm double-jacketed SMPTE 311M studio cable designed for...
More Bulk Wire Cable
- 8632MN — The 8632MN is a SpaceMaker™ 15-conductor 16 AWG tinned copper cable with polypro...
- 1385 — The Belden 1385 is a heavy-duty, 1000V rated power and control cable featuring 6...
- 78368 — The Belden 78368 is an ECOCABLE featuring 8 pairs of 26 AWG stranded tinned copp...
- 2121A — The Belden 2121A is an 8-pair 18 AWG tinned copper fieldbus cable with XLPO insu...
- 9779MN — The 9779MN is a SpaceMaker™ 4-pair 18 AWG tinned copper cable with polypropylene...
- 25162 — Belden 25162 is an XTRAGUARD 2 two-conductor cable with 18 AWG (16x30) tinned co...
- 7801A — The part 7801A is a discontinued metric video triax cable manufactured by Belden...
- 8413 — The Belden 8413 is a discontinued 2-conductor 24 AWG tinned copper alloy microph...
5198C FAQ
What is 5198C?
5198C is a Bulk Wire Cable from Belden. The 5198C is an 8-conductor, 22 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and operates within a temperature range of -35°C to +105°C. It is designed for industrial control systems, instrumentation and control circuits, PLC and DCS systems, and sensor/encoder applications, supporting both analog and digital signals.
Who manufactures 5198C?
5198C is manufactured by Belden.
Where can I download the 5198C datasheet PDF?
The 5198C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 5198C specifications
Click to ask a quick question:
Parameters
| Conductor | 8 conductors, 22 AWG (7x30) TC - Tinned Copper |
| Max. Pull Tension / Min. Bend Radius | 82 lbs (37 kg) / 1.2 in (30 mm) stationary |
| Nom. Capacitance Cond-to-Cond | 35 pF/ft (110 pF/m) |
| Nominal Outer Diameter | 0.239 in (6.07 mm) |
| Nom. Inductance | 0.18 µH/ft (0.59 µH/m) |
| Operating Temperature | -35°C to +105°C |
| Shield | Overall Aluminum/Polyester shield (100% coverage) with 22 AWG TC drainwire |
| Voltage Rating | 300 V (CMG, CM, AWM 2464, AWM 2517) |