2127A Datasheet
The Belden 2127A is a 600V fieldbus cable designed for harsh environment digital and serial two-way communication, widely used in oil and gas extraction, petrochemical sites, and process automation systems like Profibus and Foundation FieldBus. It features a single 1-pair 16AWG tinned copper conductor with XLPE insulation, an overall Beld foil shield with a drain wire, and a rugged TPE outer jacket. The cable is engineered to withstand extreme temperatures, moisture, dust, oil exposure, and long-distance remote installations.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
2127A Key Specifications
- Max. Current
- 11.6 Amps per Conductor at 25°C
- Voltage Rating
- 600 V UL
- Operating Temperature
- -40°C to +90°C Wet/Dry (UL temperature 90°C)
- Characteristic Impedance
- 100 Ohm nominal
- Conductor
- 1 Pair 16 AWG (7x24) Tinned Copper (TC)
- Max. Pull Tension / Cable Weight
- 93 lbs (42 kg) / 67 lbs/1000ft
- Nom. Conductor DCR
- 4.5 Ohm/1000ft
- Nominal Outer Diameter
- 0.374 in (9.50 mm)
Characteristics (datasheet)
- Conductor
- 1 Pair 16 AWG (7x24) Tinned Copper (TC)
- Voltage Rating
- 600 V UL
- Characteristic Impedance
- 100 Ohm nominal
- Operating Temperature
- -40°C to +90°C Wet/Dry (UL temperature 90°C)
- Max. Current
- 11.6 Amps per Conductor at 25°C
- Nominal Outer Diameter
- 0.374 in (9.50 mm)
- Nom. Conductor DCR
- 4.5 Ohm/1000ft
- Max. Pull Tension / Cable Weight
- 93 lbs (42 kg) / 67 lbs/1000ft
2127A Applications
- harsh environment digital and serial two-way communication
- oil and gas extraction and refining sites
- petrochemical
- Profibus process automation or Foundation FieldBus process automation
- extreme temperature environments
- exposure to humidity/moisture, dust, and oil
- remote locations long distance applications
Other Belden parts
- 1044A — The Belden 1044A is a 20-pair 16 AWG UL-listed instrumentation cable with PVC-ny...
- 23538D — Belden 23538D is a Canadian instrumentation cable (TC-ACIC) with 24 pairs of 16...
- 45384 — Belden part 45384 is an XTRAGUARD 4 four-conductor cable built with 18 AWG (16x3...
- 6710 — The Belden 6710 is a single-conductor hook-up wire with a 28 AWG tinned copper c...
- 1908A — The Belden 1908A is an individually shielded audio snake cable featuring eight 2...
- 9780MN — The Belden 9780MN is a SpaceMaker™ multi-conductor cable consisting of 5 pairs o...
- 30806 — Belden 30806 is a 6 AWG rubber lead wire with an 84x25 tinned copper conductor,...
- 88232 — The Belden 88232 is a plenum-rated triaxial RG59 cable designed primarily for an...
More Bulk Wire Cable
- 5402 — The Belden 5402 is a 2-conductor, 22 AWG tinned copper cable with PVC insulation...
- 8424 — The Belden 8424 is a flexible star quad microphone cable designed for ruggedized...
- 21661 — Belden 21661 is a 600 V Type TC/CIC power and control cable containing four stra...
- 48085A — Belden 48085A is a 7-conductor, 14 AWG (7x22 stranded bare copper) Type TC power...
- 80042 — The Belden 80042 is a 3-conductor, 16 AWG tinned copper cable with mPPE insulati...
- 29502 — Belden part 29502 is a flexible motor supply VFD cable with three 12 AWG (65x30)...
- 8336 — The Belden 8336 is a computer EIA RS-232 cable featuring 6 pairs of 24 AWG stran...
- 9509 — The Belden 9509 is a computer EIA RS-232 cable featuring 9 twisted pairs of 24 A...
2127A FAQ
What is 2127A?
2127A is a Bulk Wire Cable from Belden. The Belden 2127A is a 600V fieldbus cable designed for harsh environment digital and serial two-way communication, widely used in oil and gas extraction, petrochemical sites, and process automation systems like Profibus and Foundation FieldBus. It features a single 1-pair 16AWG tinned copper conductor with XLPE insulation, an overall Beld foil shield with a drain wire, and a rugged TPE outer jacket. The cable is engineered to withstand extreme temperatures, moisture, dust, oil exposure, and long-distance remote installations.
Who manufactures 2127A?
2127A is manufactured by Belden.
Where can I download the 2127A datasheet PDF?
The 2127A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 2127A specifications
Click to ask a quick question:
Parameters
| Characteristic Impedance | 100 Ohm nominal |
| Conductor | 1 Pair 16 AWG (7x24) Tinned Copper (TC) |
| Max. Current | 11.6 Amps per Conductor at 25°C |
| Max. Pull Tension / Cable Weight | 93 lbs (42 kg) / 67 lbs/1000ft |
| Nom. Conductor DCR | 4.5 Ohm/1000ft |
| Nominal Outer Diameter | 0.374 in (9.50 mm) |
| Operating Temperature | -40°C to +90°C Wet/Dry (UL temperature 90°C) |
| Voltage Rating | 600 V UL |