9780MN Datasheet
The Belden 9780MN is a SpaceMaker™ multi-conductor cable consisting of 5 pairs of 18 AWG stranded tinned copper conductors with polypropylene insulation. It features individual and overall Beldfoil shielding with TC drainwires and a PVC outer jacket for indoor applications. The cable is rated for 300 V UL voltage, supports a maximum current of 9.8 Amps per conductor at 30°C, and operates within a temperature range of -20°C to +80°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
9780MN Key Specifications
- Capacitance Cond-to-Cond
- 43.4 pF/ft (142 pF/m)
- Capacitance Cond-to-Shield
- 81.6 pF/ft (268 pF/m)
- Conductor DC Resistance
- 7.06 Ohm/1000ft
- Max. Current
- 9.8 Amps per conductor at 30°C
- Nominal Inductance
- 0.022 µH/ft (0.072 µH/m)
- UL Voltage Rating
- 300 V
- Operating Temperature
- -20°C to +80°C (UL temperature 80°C)
- AWM Compliance
- AWM 2937
Characteristics (datasheet)
- Conductor
- 5 pairs 18 AWG (41x34) tinned copper (TC)
- Insulation
- Polypropylene (PP), nominal thickness 0.010 in (0.25 mm)
- Shielding
- Individual and overall Beldfoil Bi-Laminate (Alum+Poly) tape, 100% coverage
- Outer Jacket
- PVC, nominal thickness 0.016 in (0.41 mm), nominal diameter 0.372 in
- UL Voltage Rating
- 300 V
- Max. Current
- 9.8 Amps per conductor at 30°C
- Operating Temperature
- -20°C to +80°C (UL temperature 80°C)
- Characteristic Impedance
- 39 Ohm
- Conductor DC Resistance
- 7.06 Ohm/1000ft
- Capacitance Cond-to-Cond
- 43.4 pF/ft (142 pF/m)
- Capacitance Cond-to-Shield
- 81.6 pF/ft (268 pF/m)
- Nominal Inductance
- 0.022 µH/ft (0.072 µH/m)
- Overall Diameter
- 0.372 in nominal
- Min. Bend Radius
- 1.488 in (37.80 mm) stationary and installation
- Max. Pull Tension
- 244.7 lbs (111.0 kg)
- Bulk Cable Weight
- 101 lbs/1000ft
- Flammability / CPR
- FT2, IEC 60332-1-2, CPR Euroclass Eca
- AWM Compliance
- AWM 2937
Other Belden parts
- 934062104 — HIRSCHMANN TEST AND MEASUREMENT 934062104 Test Lead, 4mm Banana Plug to 4mm...
- 78355 — The Belden 78355 is a 15-conductor, 20 AWG tinned copper cable with modified pol...
- 2400C — The Belden 2400C is a 2-conductor, 24 AWG tinned copper communication and contro...
- 9815 — The Belden 9815 is a 100 Ohm twinaxial cable designed specifically for direct bu...
- 934077100 — 1kV 32A Black Test Probe Cable
- 6018C — The Belden 6018C is a communication and control cable consisting of 15 pairs of...
- 5626UG — The Belden 5626UG is a nurse call and paging cable rated for CM applications, fe...
- 78209 — The Belden 78209 is a high-performance multi-conductor cable featuring 9 pairs o...
More Bulk Wire Cable
- 79262 — The Belden 79262 is a flexible, shielded 3-conductor 28 AWG tinned copper cable...
- 6368 — The 6368 is a 10-pair, 24 AWG tinned copper communication and control cable with...
- 8170 — The Belden 8170 is a computer EIA RS-232/422 and digital audio cable featuring 1...
- 1099A — The Belden 1099A is a UL-listed instrumentation cable featuring 12 triads of 16...
- 1285 — The Belden 1285 is a 1000 V RW90 power and control cable featuring bare copper c...
- 5152C — The Belden 5152C is an XTRAGUARD 1 shielded cable featuring 2 conductors of 20 A...
- 74011E — The Belden 74011E is a DataTuff® 6A cable with 4 individual shielded pairs of 23...
- 9421 — The Belden 9421 is an 8-conductor, 22AWG tinned copper cable with PVC insulation...
9780MN FAQ
What is 9780MN?
9780MN is a Bulk Wire Cable from Belden. The Belden 9780MN is a SpaceMaker™ multi-conductor cable consisting of 5 pairs of 18 AWG stranded tinned copper conductors with polypropylene insulation. It features individual and overall Beldfoil shielding with TC drainwires and a PVC outer jacket for indoor applications. The cable is rated for 300 V UL voltage, supports a maximum current of 9.8 Amps per conductor at 30°C, and operates within a temperature range of -20°C to +80°C.
Who manufactures 9780MN?
9780MN is manufactured by Belden.
Where can I download the 9780MN datasheet PDF?
The 9780MN datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 9780MN specifications
Click to ask a quick question:
Parameters
| AWM Compliance | AWM 2937 |
| Bulk Cable Weight | 101 lbs/1000ft |
| Capacitance Cond-to-Cond | 43.4 pF/ft (142 pF/m) |
| Capacitance Cond-to-Shield | 81.6 pF/ft (268 pF/m) |
| Characteristic Impedance | 39 Ohm |
| Conductor | 5 pairs 18 AWG (41x34) tinned copper (TC) |
| Conductor DC Resistance | 7.06 Ohm/1000ft |
| Flammability / CPR | FT2, IEC 60332-1-2, CPR Euroclass Eca |
| Insulation | Polypropylene (PP), nominal thickness 0.010 in (0.25 mm) |
| Max. Current | 9.8 Amps per conductor at 30°C |
| Max. Pull Tension | 244.7 lbs (111.0 kg) |
| Min. Bend Radius | 1.488 in (37.80 mm) stationary and installation |
| Nominal Inductance | 0.022 µH/ft (0.072 µH/m) |
| Operating Temperature | -20°C to +80°C (UL temperature 80°C) |
| Outer Jacket | PVC, nominal thickness 0.016 in (0.41 mm), nominal diameter 0.372 in |
| Overall Diameter | 0.372 in nominal |
| Shielding | Individual and overall Beldfoil Bi-Laminate (Alum+Poly) tape, 100% coverage |
| UL Voltage Rating | 300 V |