1480A Datasheet
The 1480A is a 24-pair instrumentation cable with 18 and 22 AWG bare copper conductors, PVC insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 300V (PLTC, CMG, AWM 2464) and 150V (ITC), with an operating temperature range of -30°C to +105°C. This cable is designed for industrial control, raceways, digital instruments, encoders, solenoids, valves, actuators, and DCS/PLC systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1480A Key Specifications
- Max Current
- 5 Amps per conductor @ 30°C (pairs), 9.6 Amps per conductor @ 30°C (comm wire)
- Voltage Rating
- 300 V (PLTC, CMG, AWM 2464), 150 V (ITC)
- Operating Temperature
- -30°C to +105°C
- Bend Radius
- 12.7 in (323 mm) min stationary/installation
- Conductor
- 24 pairs 18 AWG (7x26) & 1 comm wire 22 AWG (7x30) Bare Copper
- Outer Jacket
- Black PVC, 0.074 in (1.9 mm) thickness, nominal diameter 1.061 in (26.95 mm)
- Overall Cable Diameter
- 1.061 in (26.95 mm) nominal
- Shielding
- Individual & overall Beldfoil (Bi-Laminate Alum+Poly) 100% coverage with 20 AWG and 18 AWG drain wires
Characteristics (datasheet)
- Voltage Rating
- 300 V (PLTC, CMG, AWM 2464), 150 V (ITC)
- Operating Temperature
- -30°C to +105°C
- Conductor
- 24 pairs 18 AWG (7x26) & 1 comm wire 22 AWG (7x30) Bare Copper
- Shielding
- Individual & overall Beldfoil (Bi-Laminate Alum+Poly) 100% coverage with 20 AWG and 18 AWG drain wires
- Outer Jacket
- Black PVC, 0.074 in (1.9 mm) thickness, nominal diameter 1.061 in (26.95 mm)
- Max Current
- 5 Amps per conductor @ 30°C (pairs), 9.6 Amps per conductor @ 30°C (comm wire)
- Bend Radius
- 12.7 in (323 mm) min stationary/installation
- Overall Cable Diameter
- 1.061 in (26.95 mm) nominal
1480A Applications
- Industrial Control
- Raceways, Cable trays and ducts
- Digital Control
- Instruments (4-20ma, 0-10v)
- Low voltage digital control (24v)
- Encoders
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids
- Valves
- Actuators
- Positioners
Other Belden parts
- 70094A — The Belden 70094A is a discontinued Category 5e industrial Ethernet cable design...
- 5196C — The Belden 5196C (Alpha Wire) is a 6-conductor, 22 AWG tinned copper cable with...
- 6179 — The Belden 6179 is a heavy-duty Teck90 1000V cable featuring four 3/0 AWG bare c...
- 5074C — The Belden 5074C is a 4-conductor, 16 AWG tinned copper control cable with PVC i...
- 79012 — The Belden 79012 is a 4-conductor, 18 AWG tinned copper cable with modified poly...
- 77127 — The Belden 77127 is a 4-conductor 18 AWG tinned copper cable with modified polyp...
- 6371 — The Belden 6371 is an 18-pair, 24 AWG shielded communication and control cable d...
- 83504 — The Belden 83504 is a high-temperature, 4-conductor 24 AWG tinned copper electro...
More Bulk Wire Cable
- 2134A — The Belden 2134A is a 600V TC-ER fieldbus cable featuring a 24-pair 16AWG tinned...
- 23510D — Belden part 23510D is a Canadian TC-ACIC instrumentation cable rated 300 V, buil...
- 78155 — The 78155 is a 15-conductor, 20 AWG tinned copper ECOCABLE featuring modified po...
- 77032 — The Belden 77032 is a 7-conductor, 16 AWG tinned copper control cable with mPPE...
- 1748C — The Belden 1748C is a 2-conductor, 16 AWG tinned copper communication and contro...
- 82729 — The Belden 82729 is a plenum-rated, low-capacitance digital audio and computer c...
- 24509D — The Belden 24509D is a Canadian Instrumentation Cable (TC-ACIC) rated 600 V, bui...
- 4340FDW — The 4340FDW is a single-pair OSDP RS-485 transmission cable designed for use in...
1480A FAQ
What is 1480A?
1480A is a Bulk Wire Cable from Belden. The 1480A is a 24-pair instrumentation cable with 18 and 22 AWG bare copper conductors, PVC insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 300V (PLTC, CMG, AWM 2464) and 150V (ITC), with an operating temperature range of -30°C to +105°C. This cable is designed for industrial control, raceways, digital instruments, encoders, solenoids, valves, actuators, and DCS/PLC systems.
Who manufactures 1480A?
1480A is manufactured by Belden.
Where can I download the 1480A datasheet PDF?
The 1480A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1480A specifications
Click to ask a quick question:
Parameters
| Bend Radius | 12.7 in (323 mm) min stationary/installation |
| Conductor | 24 pairs 18 AWG (7x26) & 1 comm wire 22 AWG (7x30) Bare Copper |
| Max Current | 5 Amps per conductor @ 30°C (pairs), 9.6 Amps per conductor @ 30°C (comm wire) |
| Operating Temperature | -30°C to +105°C |
| Outer Jacket | Black PVC, 0.074 in (1.9 mm) thickness, nominal diameter 1.061 in (26.95 mm) |
| Overall Cable Diameter | 1.061 in (26.95 mm) nominal |
| Shielding | Individual & overall Beldfoil (Bi-Laminate Alum+Poly) 100% coverage with 20 AWG and 18 AWG drain wires |
| Voltage Rating | 300 V (PLTC, CMG, AWM 2464), 150 V (ITC) |