1359A Datasheet
The Belden 1359A is a 50-pair 18 AWG tinned copper fieldbus cable with polypropylene insulation, dual aluminum-polyester shields, and an orange PVC jacket. It is designed for harsh industrial environments, supporting digital and serial two-way communication protocols like Profibus and Foundation Fieldbus. The cable is rated for 300 V RMS, offers high noise protection with 100% shield coverage, and is suitable for oil & gas, petrochemical, and extreme temperature applications.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1359A Key Specifications
- Max. Current
- 5.2 Amps per Conductor
- Nom. Capacitance Cond-to-Shield
- 45 pF/ft (150 pF/m)
- UL Voltage Rating
- 300 V RMS
- Operating Temperature
- -40 °C to 90 °C
- UL Temperature
- 90 °C
- Bulk Cable Weight
- 1200 lbs/1000ft (1800 kg/km)
- Conductor configuration
- 50 pairs, 18 AWG (7x26) Tinned Copper (TC)
- Insulation material
- PP - Polypropylene, Nom. Thickness 0.021 in (0.53 mm)
Characteristics (datasheet)
- Conductor configuration
- 50 pairs, 18 AWG (7x26) Tinned Copper (TC)
- Insulation material
- PP - Polypropylene, Nom. Thickness 0.021 in (0.53 mm)
- Shielding
- Individual & Overall Beldfoil® Shield (Bi-Laminate Alum+Poly), 100% coverage
- Outer Jacket
- PVC - Polyvinyl Chloride, Orange, Nom. Thickness 0.085 in (2.2 mm), Nom. Diameter 1.662 in with ripcord
- Nominal Characteristic Impedance
- 100 Ohm
- Nom. Conductor DCR
- 5.86 Ohm/1000ft (19.2 Ohm/km)
- Nom. Capacitance Cond-to-Shield
- 45 pF/ft (150 pF/m)
- Nom. Velocity of Propagation
- 66%
- Bulk Cable Weight
- 1200 lbs/1000ft (1800 kg/km)
Absolute Maximum Ratings
- UL Voltage Rating
- 300 V RMS
- UL Temperature
- 90 °C
- Operating Temperature
- -40 °C to 90 °C
- Max. Pull Tension
- 2892 lbs (1312 kg)
- Max. Current
- 5.2 Amps per Conductor
1359A Applications
- Harsh environment digital and serial two-way communication
- Oil and gas extraction and refining sites
- Petrochemical
- Profibus process automation or Foundation FieldBus process automation
- Extreme temperature environments
- Exposure to humidity/moisture, dust, and oil
- Remote locations long distance applications
Other Belden parts
- 5331C — The Belden 5331C is a shielded, multi-pair cable featuring seven 24 AWG tinned c...
- 73012W — The Belden 73012W is a MachFlex™ moderate flex cable designed for robotics and c...
- 70063CH — The Belden 70063CH is a 1 x quad snake audio cable with 26 AWG bare copper condu...
- 5306C — The Belden 5306C is a 37-conductor, 24 AWG tinned copper control cable with semi...
- 85005 — The Belden 85005 is a 5-conductor, 20 AWG bare copper XTRAGUARD FLEX continuous...
- 6222C — The Belden 6222C is a shielded, low-voltage communication and control cable cons...
- 1085A — The Belden 1085A is a shielded instrumentation cable consisting of 12 twisted tr...
- 79020 — The Belden 79020 is a 3-conductor, 16 AWG tinned copper cable with mPPE insulati...
More Bulk Wire Cable
- 25271 — Belden part 25271 is an XTRAGUARD 2 cable consisting of one 24 AWG (7x32) tinned...
- 80126 — The Belden 80126 is a 12-conductor, 20 AWG tinned copper cable with modified pol...
- 1934 — The Belden 1934 is a heavy-duty 2-conductor 18 AWG stranded bare copper cord wit...
- 28627A — Belden 28627A is a 37-conductor, 16 AWG (7x24 stranded bare copper) power and co...
- 83030 — The Belden 83030 is a high-temperature plastic lead wire featuring a 16 AWG silv...
- 78025 — The Belden 78025 is a multi-conductor ECOCABLE featuring 5 pairs of 24 AWG stran...
- 2132A — The Belden 2132A is a 16-pair Fieldbus cable with 16 AWG tinned copper conductor...
- 29522 — Belden 29522 is a premium VFD power cable with three 12 AWG (65 x 30) tinned cop...
1359A FAQ
What is 1359A?
1359A is a Bulk Wire Cable from Belden. The Belden 1359A is a 50-pair 18 AWG tinned copper fieldbus cable with polypropylene insulation, dual aluminum-polyester shields, and an orange PVC jacket. It is designed for harsh industrial environments, supporting digital and serial two-way communication protocols like Profibus and Foundation Fieldbus. The cable is rated for 300 V RMS, offers high noise protection with 100% shield coverage, and is suitable for oil & gas, petrochemical, and extreme temperature applications.
Who manufactures 1359A?
1359A is manufactured by Belden.
Where can I download the 1359A datasheet PDF?
The 1359A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1359A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 1200 lbs/1000ft (1800 kg/km) |
| Conductor configuration | 50 pairs, 18 AWG (7x26) Tinned Copper (TC) |
| Insulation material | PP - Polypropylene, Nom. Thickness 0.021 in (0.53 mm) |
| Max. Current | 5.2 Amps per Conductor |
| Max. Pull Tension | 2892 lbs (1312 kg) |
| Nom. Capacitance Cond-to-Shield | 45 pF/ft (150 pF/m) |
| Nom. Conductor DCR | 5.86 Ohm/1000ft (19.2 Ohm/km) |
| Nominal Characteristic Impedance | 100 Ohm |
| Nom. Velocity of Propagation | 66% |
| Operating Temperature | -40 °C to 90 °C |
| Outer Jacket | PVC - Polyvinyl Chloride, Orange, Nom. Thickness 0.085 in (2.2 mm), Nom. Diameter 1.662 in with ripcord |
| Shielding | Individual & Overall Beldfoil® Shield (Bi-Laminate Alum+Poly), 100% coverage |
| UL Temperature | 90 °C |
| UL Voltage Rating | 300 V RMS |