FA2-P0-14-830-22A-BT Datasheet
Carling TechnologiesCircuit Breaker
Hydraulic Magnetic Circuit Breaker, 2-Pole, 125VDC, 300A, Panel Mount
FA2-P0-14-830-22A-BT Key Specifications
- Current Rating
- 300
- Voltage Rating
- 125VDC
- Max Operating Temperature
- 85 °C
- Min Operating Temperature
- -40 °C
- Actuator Type
- Handle
- Number of Poles
- 2
- Trip Time
- 2.5s to 15s
- Type
- Hydraulic Magnetic
FA2-P0-14-830-22A-BT Pinout & Package
- Number of Terminals
- 4
- Mounting
- Panel Mount
- Terminal Design
- Screw
The full pin configuration and pin descriptions are in the FA2-P0-14-830-22A-BT PDF datasheet above.
FA2-P0-14-830-22A-BT Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
FT2 -MA-16-830-21A-BT
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FT2-PB-14-830-22A-BT
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FA2-MA-16-830-22A-BT
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FA2-P0-14-830-42A-BT
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FS2-PB-14-830-22A-BT
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FA2-PB-16-830-22A-BT
Hydraulic Magnetic Circuit Breaker, 2-Pole, 125VDC, 300A, 22-150s Trip Time
Similar parts
Matching key ratings; package or pinout may differ.
JTEP-2-1-52-2-F1-300
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FA2-P0-16-830-31A-BT
2-Pole Hydraulic Magnetic Circuit Breaker, 125VDC, 300A, Panel Mount
JTEP-2-1-53-3-F1-300
Circuit Breaker Hydraulic Magnetic 2Pole 300A 160VDC
Check pinout and ratings in both datasheets before substituting.
Other Carling Technologies parts
- EA2-B0-14-610-12A-SB — Circuit Breaker Ideal for Higher Current and Voltage Applications
- FA3-P0-11-870-22A-BT — 3-Pole Hydraulic Magnetic Circuit Breaker, 125VDC, 700A, Panel Mount
- PDQ-B-26-632-E-2A1-1-C — Circuit Breaker Equipment Leakage 3Pole 32A 480VAC
- FA2-B0-14-815-42A-BJ — Hydraulic Magnetic Switch, 2-Pole, 125VDC, 150A, Panel Mount
- AA1-B0-10-425-3B1-C — Hydraulic Magnetic Circuit Breaker
- PBA-BC-26-615-1PA-AG — Panel Mount Equipment Leakage Rocker Switch 120VAC 15A -35C to 65C
- DA1-B0-34-610-121-C — Circuit Breaker Hydraulic Magnetic 1Pole 10A 277VAC/65VDC
- PDB-B-22-640-E-1BC-1-A — Circuit Breaker Equipment Leakage 2Pole 40A 120VAC/240VAC
More Circuit Breakers
- UPL11-1-64-752 — Circuit Breaker Magnetic 2Pole 7.5A
- BU3FHC-030L1WKF2 — Circuit Breaker Thermal Magnetic 3Pole 30A 600VAC/250VDC
- BU2EHC-025Y1WKRM — Circuit Breaker Thermal Magnetic 2Pole 25A 24VDC
- UPG1-1-62-602-01 — Hydraulic Magnetic Switch, Panel Mount, 6A, 2s-20s Trip Time, -40 to 85°C
- 203-2-1-65-252-S-3-5 — Supplementary Protector
- BU2EHC-0100LW2KRN — Circuit Breaker Thermal Magnetic 2Pole 100A 48VDC
- AU-2C50DL — Circuit Breaker Thermal Magnetic 2Pole 50A 250VDC
- 203-2-1-50-502-5-1-15 — Supplementary Protector
FA2-P0-14-830-22A-BT FAQ
What is FA2-P0-14-830-22A-BT?
FA2-P0-14-830-22A-BT is a Circuit Breaker from Carling Technologies. Hydraulic Magnetic Circuit Breaker, 2-Pole, 125VDC, 300A, Panel Mount.
Who manufactures FA2-P0-14-830-22A-BT?
FA2-P0-14-830-22A-BT is manufactured by Carling Technologies.
What package and pinout does FA2-P0-14-830-22A-BT have?
FA2-P0-14-830-22A-BT comes in 4 pins, panel mount mounting. The pin configuration and pin descriptions are given in the PDF datasheet.
What is the operating temperature range of FA2-P0-14-830-22A-BT?
FA2-P0-14-830-22A-BT operates from -40 °C to 85 °C.
Where can I download the FA2-P0-14-830-22A-BT datasheet PDF?
The FA2-P0-14-830-22A-BT datasheet PDF (3 MB) can be downloaded free from this page using the Download PDF button.
What are the equivalents or alternatives to FA2-P0-14-830-22A-BT?
Parts with a similar function (Circuit Breaker) include FT2 -MA-16-830-21A-BT, FT2-PB-14-830-22A-BT, FA2-MA-16-830-22A-BT. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Carling Technologies
- File Size
- 3 MB
Ask AI Assistant
Ask questions about FA2-P0-14-830-22A-BT specifications
Click to ask a quick question:
Parameters
| Actuator Type | Handle |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 73559 |
| Current Rating | 300 |
| ECCN | EAR99 |
| EU RoHS | Yes |
| HTS Code | 8536200040 |
| Max Operating Temperature | 85 |
| Min Operating Temperature | -40 |
| Mounting | Panel Mount |
| Number of Poles | 2 |
| Number of Terminals | 4 |
| PPAP | No |
| RoHS Versions | 2002/95/EC |
| Schedule B | 8536300000 |
| Terminal Design | Screw |
| Trip Time | 2.5s to 15s |
| Type | Hydraulic Magnetic |