FT2 -MA-16-830-21A-BT Datasheet
Carling TechnologiesCircuit Breaker
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FT2 -MA-16-830-21A-BT Key Specifications
- Current Rating
- 300
- Voltage Rating
- 125VDC
- Max Operating Temperature
- 85 °C
- Min Operating Temperature
- -40 °C
- Actuator Type
- Handle
- Number of Poles
- 2
- Trip Time
- 22s to 150s
- Type
- Hydraulic Magnetic
FT2 -MA-16-830-21A-BT Pinout & Package
- Number of Terminals
- 6
- Mounting
- Panel Mount
- Terminal Design
- Screw
The full pin configuration and pin descriptions are in the FT2 -MA-16-830-21A-BT PDF datasheet above.
FT2 -MA-16-830-21A-BT Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
FA2-MA-16-830-22A-BT
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FA2-P0-14-830-21A-BA
2-Pole Hydraulic Magnetic Circuit Breaker, 125VDC, 300A, Panel Mount
FT2-PB-14-830-22A-BT
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FA2-P0-14-830-42A-BT
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FS2-PB-14-830-22A-BT
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
FA2-P0-16-830-21A-BT
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
Similar parts
Matching key ratings; package or pinout may differ.
FA2-P0-16-830-31A-BT
2-Pole Hydraulic Magnetic Circuit Breaker, 125VDC, 300A, Panel Mount
JTEP-2-1-52-2-F1-300
Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC
JTEP-2-1-53-3-F1-300
Circuit Breaker Hydraulic Magnetic 2Pole 300A 160VDC
Check pinout and ratings in both datasheets before substituting.
Other Carling Technologies parts
- AA1-B0-22-425-1B2-C — Hydraulic Magnetic Circuit Breaker
- EA1-B0-66-675-22A-DI — Hydraulic Magnetic Circuit Breaker
- B51-B0-24-616-81C-K3 — Circuit Breaker Hydraulic Magnetic 1Pole 16A 120VAC
- AA1-B0-12-632-HT2-E — Hydraulic Magnetic Circuit Breaker
- CT1X013517311MG/RB1120CT1G — Hydraulic Magnetic Circuit Breaker
- EA1-B0-16-912-22A-ZB — Hydraulic Magnetic Circuit Breaker
- CLB-303-27ENN-W-H — Circuit Breaker Thermal 1Pole 30A 125VAC/250VAC/32VDC
- CT1B214810A21C/RB2306CUIC — Hydraulic Magnetic Circuit Breaker, 80VDC, 100A, 0.6s-20s Trip Time, Panel Mount
More Circuit Breakers
- 219-3-1-42-4-9-70 — Circuit Breaker Hydraulic Magnetic 3Pole 70A 240VAC
- 51014338 — Circuit Breaker Thermal 15A 28VDC
- 219-3-1-66-7-2-40 — Circuit Breaker Magnetic 3Pole 40A 600VAC
- BU3FHC-0100Y1W2KRG — Circuit Breaker Thermal Magnetic 3Pole 100A 12VDC
- JTEP-2-1-52-1-B1-400 — Hydraulic Magnetic Switch, 2-Pole, 65VDC, 400A, 2-15s Trip Time
- AP112-1-71F-602 — Circuit Breaker Hydraulic Magnetic 3Pole 6A 240VAC
- 209-2-1REC4-63-3-9-35-AH — Circuit Breaker Magnetic 2Pole 35A 240VAC
- 219-3-1-64-8-2-85 — Circuit Breaker Magnetic 3Pole 85A 240VAC
FT2 -MA-16-830-21A-BT FAQ
What is FT2 -MA-16-830-21A-BT?
FT2 -MA-16-830-21A-BT is a Circuit Breaker from Carling Technologies. Circuit Breaker Hydraulic Magnetic 2Pole 300A 125VDC.
Who manufactures FT2 -MA-16-830-21A-BT?
FT2 -MA-16-830-21A-BT is manufactured by Carling Technologies.
What package and pinout does FT2 -MA-16-830-21A-BT have?
FT2 -MA-16-830-21A-BT comes in 6 pins, panel mount mounting. The pin configuration and pin descriptions are given in the PDF datasheet.
What is the operating temperature range of FT2 -MA-16-830-21A-BT?
FT2 -MA-16-830-21A-BT operates from -40 °C to 85 °C.
Where can I download the FT2 -MA-16-830-21A-BT datasheet PDF?
The FT2 -MA-16-830-21A-BT datasheet PDF (3 MB) can be downloaded free from this page using the Download PDF button.
What are the equivalents or alternatives to FT2 -MA-16-830-21A-BT?
Parts with a similar function (Circuit Breaker) include FA2-MA-16-830-22A-BT, FA2-P0-14-830-21A-BA, FT2-PB-14-830-22A-BT. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Carling Technologies
- File Size
- 3 MB
Ask AI Assistant
Ask questions about FT2 -MA-16-830-21A-BT specifications
Click to ask a quick question:
Parameters
| Actuator Type | Handle |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 73559 |
| Current Rating | 300 |
| ECCN | EAR99 |
| EU RoHS | Yes |
| HTS Code | 8536200040 |
| Max Operating Temperature | 85 |
| Min Operating Temperature | -40 |
| Mounting | Panel Mount |
| Number of Poles | 2 |
| Number of Terminals | 6 |
| PPAP | No |
| RoHS Versions | 2002/95/EC |
| Schedule B | 8536300000 |
| Terminal Design | Screw |
| Trip Time | 22s to 150s |
| Type | Hydraulic Magnetic |
| Voltage Rating | 125VDC |