9118 Datasheet

BeldenBulk Wire Cable

The Belden 9118 is a CATV video coaxial cable (RG6 type) featuring an 18 AWG solid bare copper-covered steel conductor and gas-injected foam polyethylene insulation. It is triple-shielded with Duobond III (aluminum braid and tri-laminate tapes) and encased in a CM PVC jacket. It is designed for indoor applications, offering a nominal characteristic impedance of 75 Ohm and an operating temperature range of -40°C to +80°C.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

9118 Key Specifications

Nominal Capacitance (Conductor to Shield)
16.2 pF/ft
UL Voltage Rating
350 V RMS
Operating Temperature Range
-40°C to +80°C
Conductor
18 AWG Solid BCCS (Bare Copper Covered Steel), 0.04 in
Maximum Recommended Pulling Tension
126 lbs
Nominal Characteristic Impedance
75 Ohm
Outer Jacket
PVC (Polyvinyl Chloride), 0.275 in, CM rating
Outer Shield Configuration
Tri Shield: Tape 1 Duofoil (100%), Braid 2 Aluminum (60%), Tape 3 Duofoil (100%)

Characteristics (datasheet)

Nominal Characteristic Impedance
75 Ohm
Conductor
18 AWG Solid BCCS (Bare Copper Covered Steel), 0.04 in
Nominal Capacitance (Conductor to Shield)
16.2 pF/ft
Outer Shield Configuration
Tri Shield: Tape 1 Duofoil (100%), Braid 2 Aluminum (60%), Tape 3 Duofoil (100%)
Outer Jacket
PVC (Polyvinyl Chloride), 0.275 in, CM rating
UL Voltage Rating
350 V RMS
Operating Temperature Range
-40°C to +80°C
Maximum Recommended Pulling Tension
126 lbs

Other Belden parts

  • 5586C — The Belden 5586C is a 37-conductor, 22 AWG tinned copper cable with semi-rigid P...
  • 78098 — The Belden 78098 is an ECOCABLE featuring 8 pairs of 20 AWG tinned copper conduc...
  • 1761 — The Belden 1761 is a 3-conductor, 12 AWG tinned copper control and communication...
  • 23519D — The Belden 23519D is a Canadian instrumentation cable (TC-ACIC) rated 300 V, con...
  • 1052A — The Belden 1052A is a UL-listed instrumentation cable consisting of 16 pairs of...
  • 80050 — The 80050 is a 36-conductor, 16 AWG tinned copper cable with MPPE insulation and...
  • 65402 — The part 65402 is an XTRAGUARD FLEX flexible control cable consisting of 2 condu...
  • 2109A — The Belden 2109A is a robust fieldbus cable designed for harsh-environment digit...

More Bulk Wire Cable

  • 9936 — The Belden 9936 is a computer EIA RS-232/423 cable featuring 15 conductors of 24...
  • 5409 — The Belden 5409 is a 9-conductor, 22 AWG tinned copper cable with PVC insulation...
  • 3083A — The 3083A is a 2-pair tinned copper cable (15 AWG power pair and 18 AWG data pai...
  • 9508 — The product 9508 is a computer EIA RS-232 cable with 8 twisted pairs of 24 AWG s...
  • 5509UE — The Belden 5509UE is a riser-CMR security and sound cable containing 12 stranded...
  • 9410 — The Belden 9410 is a high-performance instrumentation cable consisting of a sing...
  • 4855P — The Belden 4855P is a 12 GHz, 4K UHD precision video coaxial cable designed as a...
  • 6052 — Part 6052 is a Teck90 600V cable consisting of 20 plus 1 ground conductor of 14...

9118 FAQ

What is 9118?

9118 is a Bulk Wire Cable from Belden. The Belden 9118 is a CATV video coaxial cable (RG6 type) featuring an 18 AWG solid bare copper-covered steel conductor and gas-injected foam polyethylene insulation. It is triple-shielded with Duobond III (aluminum braid and tri-laminate tapes) and encased in a CM PVC jacket. It is designed for indoor applications, offering a nominal characteristic impedance of 75 Ohm and an operating temperature range of -40°C to +80°C.

Who manufactures 9118?

9118 is manufactured by Belden.

Where can I download the 9118 datasheet PDF?

The 9118 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 9118 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor18 AWG Solid BCCS (Bare Copper Covered Steel), 0.04 in
Maximum Recommended Pulling Tension126 lbs
Nominal Capacitance (Conductor to Shield)16.2 pF/ft
Nominal Characteristic Impedance75 Ohm
Operating Temperature Range-40°C to +80°C
Outer JacketPVC (Polyvinyl Chloride), 0.275 in, CM rating
Outer Shield ConfigurationTri Shield: Tape 1 Duofoil (100%), Braid 2 Aluminum (60%), Tape 3 Duofoil (100%)
UL Voltage Rating350 V RMS