2109A Datasheet
The Belden 2109A is a robust fieldbus cable designed for harsh-environment digital and serial two-way communication. It features a single 1-pair 16 AWG tinned copper conductor with XLPE insulation, dual Beldfoil shields, and a durable TPE outer jacket. This cable is built to perform reliably in extreme temperatures, moisture, oil, and dust, making it ideal for oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
2109A Key Specifications
- Max. Current
- 6.1 Amps per Conductor
- Nominal Capacitance (Cond-to-Shield)
- 22 pF/ft (72 pF/m)
- UL Voltage Rating
- 300 V
- Operating Temperature
- -40°C to +90°C
- Characteristic Impedance
- 120 Ohm
- Conductor
- 1 Pair 16 AWG (7x24) Tinned Copper (TC)
- Max. Pull Tension
- 71.4 lbs (32.4 kg)
- Outer Jacket
- TPE - Thermoplastic Elastomer, 0.047 in (1.2 mm) thickness, 0.365 in (9.27 mm) nominal diameter
Characteristics (datasheet)
- Conductor
- 1 Pair 16 AWG (7x24) Tinned Copper (TC)
- Characteristic Impedance
- 120 Ohm
- Nominal Capacitance (Cond-to-Shield)
- 22 pF/ft (72 pF/m)
- Max. Current
- 6.1 Amps per Conductor
- UL Voltage Rating
- 300 V
- Operating Temperature
- -40°C to +90°C
- Outer Jacket
- TPE - Thermoplastic Elastomer, 0.047 in (1.2 mm) thickness, 0.365 in (9.27 mm) nominal diameter
- Max. Pull Tension
- 71.4 lbs (32.4 kg)
2109A Applications
- Harsh environment digital and serial two-way communication
- Oil and gas extraction and refining sites
- Petrochemical industry
- Profibus process automation or Foundation FieldBus process automation
- Extreme temperature environments
- Environments with exposure to humidity/moisture, dust, and oil
- Remote locations long distance applications
Other Belden parts
- 85812 — The Belden 85812 (Alpha Wire) is a 12-conductor, 18 AWG bare copper control cabl...
- 6059 — The Belden 6059 is a Teck90 600V power and control cable designed for use in CEC...
- 1776 — The Belden 1776 is a discontinued 2-conductor 20 AWG microphone cable designed f...
- 3130A — The Belden 3130A is a heavy-duty UL instrumentation cable featuring 36 triads of...
- 5314C — The Belden 5314C is a 19-conductor, 22 AWG shielded cable with semi-rigid PVC in...
- 78306 — The Belden 78306 is a 6-conductor, 28 AWG tinned copper ECOCABLE with modified p...
- 78449 — The Belden 78449 is an ECOCABLE consisting of 25 pairs of 22 AWG stranded tinned...
- 25362 — Belden 25362 is an XTRAGUARD 2 cable with 2 conductors of 16 AWG (19x29) tinned...
More Bulk Wire Cable
- 8641 — The Belden 8641 is a 2-conductor 24AWG tinned copper cable with polyethylene ins...
- 9159 — The Belden 9159 is a 5-pair 18 AWG tinned copper electronic cable with PVC insul...
- 5003C — The Belden 5003C is a 3-conductor, 22 AWG tinned copper control cable with semi-...
- 80045 — The Belden 80045 is a zero-halogen, 7-conductor 16 AWG tinned copper cable with...
- 6828 — The Belden 6828 is a single-conductor hook-up wire featuring 15 AWG bare copper...
- 6604HS — The 6604HS is a discontinued analog audio cable manufactured by Gepco (a Belden...
- 78329 — The Belden 78329 is an ECOCABLE featuring 9 pairs of 24 AWG tinned copper conduc...
- 58804 — The Belden 58804 is a communication and control cable featuring 4 pairs of 24 AW...
2109A FAQ
What is 2109A?
2109A is a Bulk Wire Cable from Belden. The Belden 2109A is a robust fieldbus cable designed for harsh-environment digital and serial two-way communication. It features a single 1-pair 16 AWG tinned copper conductor with XLPE insulation, dual Beldfoil shields, and a durable TPE outer jacket. This cable is built to perform reliably in extreme temperatures, moisture, oil, and dust, making it ideal for oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation systems.
Who manufactures 2109A?
2109A is manufactured by Belden.
Where can I download the 2109A datasheet PDF?
The 2109A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 2109A specifications
Click to ask a quick question:
Parameters
| Characteristic Impedance | 120 Ohm |
| Conductor | 1 Pair 16 AWG (7x24) Tinned Copper (TC) |
| Max. Current | 6.1 Amps per Conductor |
| Max. Pull Tension | 71.4 lbs (32.4 kg) |
| Nominal Capacitance (Cond-to-Shield) | 22 pF/ft (72 pF/m) |
| Operating Temperature | -40°C to +90°C |
| Outer Jacket | TPE - Thermoplastic Elastomer, 0.047 in (1.2 mm) thickness, 0.365 in (9.27 mm) nominal diameter |
| UL Voltage Rating | 300 V |