The Belden 6001 is a Teck90 1000V power and control cable featuring 3+G conductors (1 AWG and 6 AWG bare copper) with XLPE insulation, a PVC inner jacket, steel interlock armor, and a black PVC outer jacket. It is designed for indoor and outdoor use, offering sunlight and UV resistance, and supports operating temperatures ranging from -40°C to +90°C. The cable is rated for a maximum current of 145 Amps per conductor at 30°C and complies with CEC / C(UL) TECK 90, HL standards.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
6001 Key Specifications
- Max. Current per Conductor
- 145 Amps per Conductor at 30ºC
- Voltage Rating
- 1000 V (TECK 90)
- Operating Temperature
- -40°C To +90°C
- Bulk Cable Weight
- 2053 lbs/1000ft
- Conductors
- 3 x 1 AWG (19x14) Bare Copper, 1 x 6 AWG (7x14) Bare Copper Ground
- Max. Pull Tension
- 3708.3 lbs (1682.1 kg)
- Overall Cable Diameter (Nominal)
- 1.569 in
- Stationary Min. Bend Radius
- 12.552 in (318.82 mm)
Characteristics (datasheet)
- Voltage Rating
- 1000 V (TECK 90)
- Conductors
- 3 x 1 AWG (19x14) Bare Copper, 1 x 6 AWG (7x14) Bare Copper Ground
- Max. Current per Conductor
- 145 Amps per Conductor at 30ºC
- Operating Temperature
- -40°C To +90°C
- Overall Cable Diameter (Nominal)
- 1.569 in
- Max. Pull Tension
- 3708.3 lbs (1682.1 kg)
- Bulk Cable Weight
- 2053 lbs/1000ft
- Stationary Min. Bend Radius
- 12.552 in (318.82 mm)
6001 Applications
- CEC Power and Control Applications
Other Belden parts
- 1624P — The 1624P is a Category 5 Premise Horizontal Cable (100MHz) featuring 4 pairs of...
- 8112 — The Belden 8112 is a low-capacitance computer EIA RS-232/422 cable featuring 12...
- 2244C — The Belden 2244C is a communication and control cable featuring four 18 AWG tinn...
- 85612 — The Belden 85612 is an XTRAGUARD FLEX continuous flex control cable featuring 12...
- 9365 — The Belden 9365 is a high-performance instrumentation cable featuring one 18 AWG...
- 9779MN — The 9779MN is a SpaceMaker™ 4-pair 18 AWG tinned copper cable with polypropylene...
- 8125 — The Belden 8125 is a computer EIA RS-232/422 cable featuring 25 twisted pairs of...
- 9911 — The Belden 9911 is a low-temp plastic lead wire with an 18 AWG (16x30) tinned co...
More Bulk Wire Cable
- 9934 — The Belden 9934 is a 9-conductor computer communications cable designed for EIA...
- 85168 — The Belden 85168 is a high-temperature electronic cable featuring 8 pairs of 20A...
- 55092 — The Belden 55092 is a high-performance, 2-conductor, 24 AWG tinned copper shield...
- 83515 — The Belden 83515 is a high-temperature, multi-conductor electronic cable consist...
- 4204FE — The Belden 4204FE is a security and commercial audio cable designed for security...
- 8643 — The Belden 8643 is a 3-conductor electronic cable designed for low-voltage analo...
- 27917A — The Belden 27917A is a 2-conductor, 16 AWG (7x24 stranded bare copper) Type TC p...
- 9008 — The Belden 9008 is a single-conductor coaxial cable featuring a 13 AWG bare copp...
6001 FAQ
What is 6001?
6001 is a Bulk Wire Cable from Belden. The Belden 6001 is a Teck90 1000V power and control cable featuring 3+G conductors (1 AWG and 6 AWG bare copper) with XLPE insulation, a PVC inner jacket, steel interlock armor, and a black PVC outer jacket. It is designed for indoor and outdoor use, offering sunlight and UV resistance, and supports operating temperatures ranging from -40°C to +90°C. The cable is rated for a maximum current of 145 Amps per conductor at 30°C and complies with CEC / C(UL) TECK 90, HL standards.
Who manufactures 6001?
6001 is manufactured by Belden.
Where can I download the 6001 datasheet PDF?
The 6001 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 6001 specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 2053 lbs/1000ft |
| Conductors | 3 x 1 AWG (19x14) Bare Copper, 1 x 6 AWG (7x14) Bare Copper Ground |
| Max. Current per Conductor | 145 Amps per Conductor at 30ºC |
| Max. Pull Tension | 3708.3 lbs (1682.1 kg) |
| Operating Temperature | -40°C To +90°C |
| Overall Cable Diameter (Nominal) | 1.569 in |
| Stationary Min. Bend Radius | 12.552 in (318.82 mm) |
| Voltage Rating | 1000 V (TECK 90) |