5522 Datasheet
The Belden 5522 is a 2-conductor, 18 AWG tinned copper cable with PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for 600 V, supports an operating temperature range of -30°C to +105°C, and meets various AWM, MTW, CSA, and flammability standards.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
5522 Key Specifications
- Nom. capacitance cond-to-cond
- 34 pF/ft (110 pF/m)
- Voltage rating
- 600 V (MTW, AWM 20811, AWM 2501 / CSA AWM)
- Operating Temperature
- -30°C to +105°C (UL Temperature 105°C)
- Operating temperature range
- -30°C to +105°C
- Conductor configuration
- 2 conductors, 18 AWG (16x30 strand), TC - Tinned Copper
- Max. Pull Tension
- 102 lbs (46.3 kg)
- Max. pull tension / Min. bend radius
- 102 lbs (46.3 kg) / 3.8 in (97 mm) stationary min.
- Nom. characteristic impedance
- 62 Ohm
5522 Marking Code (SMD Code)
Top marking: Alpha Wire -* P/N 5522 2C 18 AWG XTRAGUARD(R) 1 (UL) MTW 600V OR AWM 2501 105C 600V OR AWM 20811 105C 600V VW-1 OR CRU AWM I/II A/B 105C 600V FT4 CE · package Cable (2-conductor, overall shielded, slate PVC jacket)
Characteristics (datasheet)
- Conductor configuration
- 2 conductors, 18 AWG (16x30 strand), TC - Tinned Copper
- Overall cable diameter (nominal)
- 0.380 in (9.65 mm)
- Voltage rating
- 600 V (MTW, AWM 20811, AWM 2501 / CSA AWM)
- Operating temperature range
- -30°C to +105°C
- Nom. characteristic impedance
- 62 Ohm
- Nom. capacitance cond-to-cond
- 34 pF/ft (110 pF/m)
- Outer shield
- Bi-Laminate (Alum+Poly) 100% coverage; Tinned Copper (TC) 70% coverage
- Max. pull tension / Min. bend radius
- 102 lbs (46.3 kg) / 3.8 in (97 mm) stationary min.
Absolute Maximum Ratings
- Voltage Rating
- 600 V (MTW, AWM 20811, AWM 2501) / 600 V (CSA AWM)
- Operating Temperature
- -30°C to +105°C (UL Temperature 105°C)
- Max. Pull Tension
- 102 lbs (46.3 kg)
5522 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking, serial communication
- Control panels, automation equipment, and instrumentation systems
Other Belden parts
- 29730C — The Belden 29730C is a 3-conductor VFD power cable with 2/0 AWG bare copper cond...
- 934063706 — HIRSCHMANN TEST AND MEASUREMENT 934063706 Test Lead, 4mm Banana Plug to 4mm...
- 9556 — The Belden 9556 is a high-performance instrumentation cable featuring six 18 AWG...
- 57004 — The Belden 57004 is a plenum-rated, shielded 4-conductor 24 AWG bare copper cabl...
- 7792A — The 7792A is a discontinued VideoFLEX® sub-miniature digital coax snake cable wi...
- 8403 — The Belden 8403 is a 3-conductor, 20 AWG tinned copper microphone cable with pol...
- 28151A — The Belden 28151A is a UL Type TC (1277) power and control cable with four 8 AWG...
- 1671A — The Belden 1671A is a conformable, unjacketed coaxial cable with a 50 Ohm charac...
More Bulk Wire Cable
- 7057 — The Belden 7057 is a single-conductor hook-up wire with an 18 AWG tinned copper...
- 6212C — The Belden 6212C is a shielded communication and control cable featuring 2 pairs...
- 37502 — The Belden 37502 is a rubber lead wire with a 2 AWG (163x24) tinned copper condu...
- 6541FD — The Belden 6541FD is a plenum-rated (CMP) 2-pair #22 AWG stranded tinned copper...
- 5875 — The Belden 5875 is a single-conductor, 22 AWG silver-plated copper hook-up wire...
- 5384C — The 5384C is a 4-conductor, 18 AWG tinned copper cable with PVC insulation, an o...
- 70263PU — The Belden 70263PU is an 8-conductor PUR sensor and actuator cable designed for...
- 80033 — The Belden 80033 is a 3-conductor, 18 AWG tinned copper control cable with mPPE...
5522 FAQ
What is 5522?
5522 is a Bulk Wire Cable from Belden. The Belden 5522 is a 2-conductor, 18 AWG tinned copper cable with PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for 600 V, supports an operating temperature range of -30°C to +105°C, and meets various AWM, MTW, CSA, and flammability standards.
Who manufactures 5522?
5522 is manufactured by Belden.
What is the marking code of 5522?
According to its datasheet, 5522 in Cable (2-conductor, overall shielded, slate PVC jacket) is marked "Alpha Wire -* P/N 5522 2C 18 AWG XTRAGUARD(R) 1 (UL) MTW 600V OR AWM 2501 105C 600V OR AWM 20811 105C 600V VW-1 OR CRU AWM I/II A/B 105C 600V FT4 CE".
Where can I download the 5522 datasheet PDF?
The 5522 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 5522 specifications
Click to ask a quick question:
Parameters
| Conductor configuration | 2 conductors, 18 AWG (16x30 strand), TC - Tinned Copper |
| Max. Pull Tension | 102 lbs (46.3 kg) |
| Max. pull tension / Min. bend radius | 102 lbs (46.3 kg) / 3.8 in (97 mm) stationary min. |
| Nom. capacitance cond-to-cond | 34 pF/ft (110 pF/m) |
| Nom. characteristic impedance | 62 Ohm |
| Operating Temperature | -30°C to +105°C (UL Temperature 105°C) |
| Operating temperature range | -30°C to +105°C |
| Outer shield | Bi-Laminate (Alum+Poly) 100% coverage; Tinned Copper (TC) 70% coverage |
| Overall cable diameter (nominal) | 0.380 in (9.65 mm) |
| Voltage rating | 600 V (MTW, AWM 20811, AWM 2501 / CSA AWM) |