AP1-3-52F-502 Key Specifications
- Current Rating
- 5
- Voltage Rating
- 240VAC
- Max Operating Temperature
- 100 °C
- Min Operating Temperature
- -40 °C
- Actuator Type
- Handle
- Number of Poles
- 1
- Trip Time
- 0.6s to 6s
- Type
- Hydraulic Magnetic
AP1-3-52F-502 Pinout & Package
- Number of Terminals
- 2
- Mounting
- Panel Mount
- Terminal Design
- Hook
AP1-3-52F-502 Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
UP1-1-62-502-FM
Hydraulic Magnetic Switch, 240VAC, 5A, 0.8s to 8s Trip Time, Panel Mount
AP1-1RC-52F-502
Circuit Breaker Hydraulic Magnetic 1Pole 5A 240VAC
AP1-1RC-65F-502
240VAC Hydraulic Magnetic Switch, Panel Mount, 5A, 1.15s to 7s Trip Time
UP1-1-62F-502
240VAC Hydraulic Magnetic Circuit Breaker, Panel Mount, 5A, 0.8s-8s Trip Time
AP1-4-50-502
Circuit Breaker Hydraulic Magnetic 1Pole 5A 240VAC
UP1-1-52-502-FM
240VAC Hydraulic Magnetic Switch, Panel Mount, 5A, 0.6s to 6s Trip Time
Similar parts
Matching key ratings; package or pinout may differ.
209-1-1-66-4-8-5
Hydraulic Magnetic Circuit Breaker, 240VAC, 5A, Panel Mount
MB1-B-34-450-1A26-B-C
Snap-In Hydraulic Magnetic Relay, 250VAC/80VDC, 5A, 1s-15s Trip Time
MA1-B-34-450-1A26-B-C
Circuit Breaker Hydraulic Magnetic 1Pole 5A 250VAC/80VDC Automotive
MB1-B-34-450-2-A32-2-C
Circuit Breaker Hydraulic Magnetic 1Pole 5A 250VAC/80VDC Automotive
205-1-1-69-4-502-A
250VAC Hydraulic Magnetic Toggle Switch, Panel Mount, 5A, 0.05s Trip Time
DA1-B0-34-450-121-C
Hydraulic Magnetic Circuit Breaker 277VAC 65VDC 5A 0.6s-20s Trip Time
Check pinout and ratings in both datasheets before substituting.
Other Sensata parts
- 205-1-1-51-2-202-O — Circuit Breaker Magnetic 1Pole 65VDC
- AP1-1RC-42-102 — Hydraulic Magnetic Circuit Breaker, 240VAC, 1A, Handle Actuator, -40 to 100°C
- APL1-1REC4-62-153 — Circuit Breaker Magnetic 1Pole 15A
- 295-11-1-66-3-403-O — Circuit Breaker Magnetic 2Pole 40A 120VAC
- UPGN1-1-51-163 — Hydraulic Magnetic Switch, Panel Mount, 16A, 0.1s to 1.2s Trip Time
- 249-9-F-100-100-100-3-62-1 — Circuit Breaker Magnetic 9Pole
- 7851-18-20 — Circuit Breaker Thermal 20A 120VAC
- UPL11-1REC4-42-503 — 2-Pole Hydraulic Magnetic Relay, 50A, 2s-22s Trip Time, Panel Mount
More Circuit Breakers
- BU3EHC-0150Y1WKF6 — Circuit Breaker Thermal Magnetic 3Pole 150A 600VAC/250VDC
- MA1-B-36-620-1-A12-B-A — Hydraulic Magnetic Circuit Breaker
- 0900333 — Circuit Breaker Electronic 1Pole 3A 24VDC
- BU2EHC-050LW2KFG — Circuit Breaker Thermal Magnetic 2Pole 50A 250VDC
- 203-2-1-61-802-4-1-1 — Supplementary Protector
- 219-3-1-63-7-8-20 — Circuit Breaker Hydraulic Magnetic 3Pole 20A 600VAC
- 209-2-1-66-4-2-30-V — Circuit Breaker Magnetic 2Pole 30A 240VAC
- 203-2-1-52-103-6-1-8 — Circuit Breaker Supplementary Protector 1Pole 10A 32VDC
AP1-3-52F-502 FAQ
What is AP1-3-52F-502?
AP1-3-52F-502 is a Relay from Sensata. Hydraulic Magnetic Relay, 240VAC, 5A, 0.6s to 6s Trip Time, Panel Mount.
Who manufactures AP1-3-52F-502?
AP1-3-52F-502 is manufactured by Sensata.
What package and pinout does AP1-3-52F-502 have?
AP1-3-52F-502 comes in 2 pins, panel mount mounting.
What is the operating temperature range of AP1-3-52F-502?
AP1-3-52F-502 operates from -40 °C to 100 °C.
What are the equivalents or alternatives to AP1-3-52F-502?
Parts with a similar function (Relay) include UP1-1-62-502-FM, AP1-1RC-52F-502, AP1-1RC-65F-502. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Sensata
Ask AI Assistant
Ask questions about AP1-3-52F-502 specifications
Click to ask a quick question:
Parameters
| Actuator Type | Handle |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 82647 |
| Current Rating | 5 |
| ECCN | EAR99 |
| EU RoHS | No |
| HTS Code | 8536200040 |
| Max Operating Temperature | 100 |
| Min Operating Temperature | -40 |
| Mounting | Panel Mount |
| Number of Poles | 1 |
| Number of Terminals | 2 |
| PPAP | No |
| Radiation Hardening | No |
| RoHS Versions | 2011/65/EU, 2015/863 |
| Schedule B | 8536200040 |
| Terminal Design | Hook |
| Trip Time | 0.6s to 6s |
| Type | Hydraulic Magnetic |
| Voltage Rating | 240VAC |