AP1-1-61F-203 Key Specifications
- Current Rating
- 20
- Voltage Rating
- 240VAC
- Max Operating Temperature
- 100 °C
- Min Operating Temperature
- -40 °C
- Actuator Type
- Handle
- Number of Poles
- 1
- Trip Time
- 0.07s to 0.7s
- Type
- Hydraulic Magnetic
AP1-1-61F-203 Pinout & Package
- Number of Terminals
- 2
- Mounting
- Panel Mount
- Terminal Design
- Hook
The full pin configuration and pin descriptions are in the AP1-1-61F-203 PDF datasheet above.
AP1-1-61F-203 Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
UP1-1-52-203-FM
Circuit Breaker Hydraulic Magnetic 1Pole 20A 240VAC
UP1-1-51-203-FM
Circuit Breaker Hydraulic Magnetic 1Pole 20A 240VAC
AP1-1-61-203
Hydraulic Magnetic Switch, 240VAC, 20A, 0.07s-0.7s Trip Time, Panel Mount
AP1-1-51F-203
240VAC Hydraulic Magnetic Switch, 20A, Handle Actuator, -40 to 100°C
AP1-1R-42-203
240VAC Hydraulic Magnetic Switch, 20A, 0.5s to 9s Trip Time, Panel Mount
UP1-1-51F-203
Circuit Breaker Hydraulic Magnetic 1Pole 20A 240VAC
Similar parts
Matching key ratings; package or pinout may differ.
AP7-1-60-203
Circuit Breaker Hydraulic Magnetic 1Pole 20A 240VAC
AP7-1-69-203
240VAC Hydraulic Magnetic Switch, Panel Mount, 20A, 0.05s Trip Time
219-1-1-65-4-8-20-AH-V
Hydraulic Magnetic Switch, 240VAC, 20A, 2s to 18s Trip Time, Panel Mount
209-1-1REG4-63-4-9-20-H
Hydraulic Magnetic Relay, 240VAC, 20A, 20-200s Trip Time, Panel Mount
209-1-1-62-3-9-20
Circuit Breaker Hydraulic Magnetic 1Pole 20A 120VAC/240VAC
209-1-1-41-4-9-20
240VAC Hydraulic Magnetic Circuit Breaker, Panel Mount, 20A
Check pinout and ratings in both datasheets before substituting.
Other Sensata parts
- 203-2-1-62-153-4-3-1 — Supplementary Protector
- 203-2-1-61-802-4-1-1 — Supplementary Protector
- UPL1-1-52-353-M — Circuit Breaker Magnetic 1Pole 35A
- UPL11-1REC4-61-303 — Hydraulic Magnetic Relay, 2-Pole, 30A, 0.18s to 1.8s Trip Time, -40 to 85°C
- 203-222-1-42F-302-4-1-1 — Supplementary Protector
- AP1-1R-42-702 — Hydraulic Magnetic Circuit Breaker, 240VAC, 7A, Panel Mount
- CDM-40 — Circuit Breaker Thermal 40A 120VAC
- 229-3-1REC4-62-5-9-100 — Circuit Breaker Magnetic 3Pole 100A 480VAC
More Circuit Breakers
- BU2EHC-0100Y1WKR1 — Circuit Breaker Thermal Magnetic 2Pole 100A 120VAC
- BU2EHC-040Y1W2KRJ — Circuit Breaker Thermal Magnetic 2Pole 40A 125VDC
- EA2-B0-24-912-B2B-CC — 2-Pole Hydraulic Magnetic Circuit Breaker, 120/240VAC, 125A, 2-15s Trip Time
- BU2FHC-0100Y1WKRJ — Circuit Breaker Thermal Magnetic 2Pole 100A 125VDC
- UPG11-1-64F-702-91 — Circuit Breaker Magnetic 2Pole 7A
- EA1-B2-24-685-22A-CC — Hydraulic Magnetic Circuit Breaker
- 203-2-1-52-103-6-1-8 — Circuit Breaker Supplementary Protector 1Pole 10A 32VDC
- 219-3-1-65-8-9-90-A — Circuit Breaker Magnetic 3Pole 90A 480VAC
AP1-1-61F-203 FAQ
What is AP1-1-61F-203?
AP1-1-61F-203 is a Circuit Breaker from Sensata. Circuit Breaker Hydraulic Magnetic 1Pole 20A 240VAC.
Who manufactures AP1-1-61F-203?
AP1-1-61F-203 is manufactured by Sensata.
What package and pinout does AP1-1-61F-203 have?
AP1-1-61F-203 comes in 2 pins, panel mount mounting. The pin configuration and pin descriptions are given in the PDF datasheet.
What is the operating temperature range of AP1-1-61F-203?
AP1-1-61F-203 operates from -40 °C to 100 °C.
Where can I download the AP1-1-61F-203 datasheet PDF?
The AP1-1-61F-203 datasheet PDF (524 KB) can be downloaded free from this page using the Download PDF button.
What are the equivalents or alternatives to AP1-1-61F-203?
Parts with a similar function (Circuit Breaker) include UP1-1-52-203-FM, UP1-1-51-203-FM, AP1-1-61-203. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Sensata
- File Size
- 524 KB
Ask AI Assistant
Ask questions about AP1-1-61F-203 specifications
Click to ask a quick question:
Parameters
| Actuator Type | Handle |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 82647 |
| Current Rating | 20 |
| ECCN | EAR99 |
| EU RoHS | No |
| HTS Code | 8536200040 |
| Max Operating Temperature | 100 |
| Min Operating Temperature | -40 |
| Mounting | Panel Mount |
| Number of Poles | 1 |
| Number of Terminals | 2 |
| PPAP | No |
| Radiation Hardening | No |
| RoHS Versions | 2011/65/EU, 2015/863 |
| Schedule B | 8536200040 |
| Terminal Design | Hook |
| Trip Time | 0.07s to 0.7s |
| Type | Hydraulic Magnetic |
| Voltage Rating | 240VAC |