9409 Datasheet
The Belden 9409 is a high-performance instrumentation cable designed with one pair of 18 AWG stranded tinned copper conductors, PVC insulation (E2 color code), and a PVC outer jacket. It is rated for PLTC and CMG applications with a voltage rating of 300V and supports operating temperatures between -30°C and +105°C. The cable is suitable for use in instrumentation, sensors, valves, positioners, and standard signal transmission applications like 4-20mA and 0-10V.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
9409 Key Specifications
- Max. Current
- 5 Amps per Conductor at 25ºC
- Nom. Capacitance Cond-to-Cond
- 26 pF/ft (85 pF/m)
- UL Voltage Rating
- 300 V (PLTC, CMG)
- Operating Temperature
- -30°C to +105°C (UL Temperature: 105°C)
- Bend Radius (Stationary / Installation Min.)
- 2.4 in (61 mm)
- Conductor
- 1 pair, 18 AWG (19x30) Tinned Copper
- Nom. Conductor DCR
- 7.2 Ohm/1000ft
- Overall Cable Diameter (Nominal)
- 0.236 in (5.99 mm)
Characteristics (datasheet)
- Conductor
- 1 pair, 18 AWG (19x30) Tinned Copper
- Nom. Conductor DCR
- 7.2 Ohm/1000ft
- Nom. Capacitance Cond-to-Cond
- 26 pF/ft (85 pF/m)
- Max. Current
- 5 Amps per Conductor at 25ºC
- UL Voltage Rating
- 300 V (PLTC, CMG)
- Operating Temperature
- -30°C to +105°C (UL Temperature: 105°C)
- Overall Cable Diameter (Nominal)
- 0.236 in (5.99 mm)
- Bend Radius (Stationary / Installation Min.)
- 2.4 in (61 mm)
9409 Applications
- Instrumentation
- Sensors
- Valves
- Positioners
Other Belden parts
- 83265 — The Belden 83265 is a commercial, non-QPL mil-spec coaxial cable with a 50 Ohm c...
- 70007E — The Belden 70007E is a DataTuff® 5E PROFINET Type B industrial Ethernet cable de...
- 65604 — The part 65604 is an XTRAGUARD FLEX 4-conductor, 16 AWG bare copper cable with P...
- 6225C — The Belden 6225C is a shielded communication and control cable consisting of fiv...
- 6823 — The Belden 6823 is a single-conductor hook-up wire featuring a 22 AWG bare coppe...
- 1093A — The Belden 1093A is a UL-listed instrumentation cable featuring four 18 AWG bare...
- 25013 — Belden part 25013 (XTRAGUARD 2) is a 3-conductor, 24 AWG (7x32 stranded tinned c...
- 7916AP 8771000 — COAX 75 OHM RG6 18AWG PLENUM
More Bulk Wire Cable
- 1468A — The Belden 1468A is an UL-listed instrumentation and control cable featuring 12...
- 9272 — The Belden 9272 is a 78 Ohm twinaxial cable constructed with 20 AWG stranded tin...
- 84303 — The Belden 84303 is a 50 Ohm coaxial cable of the RG-303/U type, featuring a sil...
- 79003 — The Belden 79003 is a highly flexible 4-conductor 20 AWG tinned copper cable fea...
- 9802 — The Belden 9802 is a 2-conductor, 20 AWG solid tinned copper cable with polyprop...
- 6508FE — The 6508FE is a plenum-rated (CMP) security and sound cable designed for indoor...
- 28098A — The Belden 28098A is a UL Type TC (1277) PVC-nylon/PVC control cable with 20 con...
- 3233 — The Belden 3233 is a multi-conductor communication and control cable featuring 4...
9409 FAQ
What is 9409?
9409 is a Bulk Wire Cable from Belden. The Belden 9409 is a high-performance instrumentation cable designed with one pair of 18 AWG stranded tinned copper conductors, PVC insulation (E2 color code), and a PVC outer jacket. It is rated for PLTC and CMG applications with a voltage rating of 300V and supports operating temperatures between -30°C and +105°C. The cable is suitable for use in instrumentation, sensors, valves, positioners, and standard signal transmission applications like 4-20mA and 0-10V.
Who manufactures 9409?
9409 is manufactured by Belden.
Where can I download the 9409 datasheet PDF?
The 9409 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 9409 specifications
Click to ask a quick question:
Parameters
| Bend Radius (Stationary / Installation Min.) | 2.4 in (61 mm) |
| Conductor | 1 pair, 18 AWG (19x30) Tinned Copper |
| Max. Current | 5 Amps per Conductor at 25ºC |
| Nom. Capacitance Cond-to-Cond | 26 pF/ft (85 pF/m) |
| Nom. Conductor DCR | 7.2 Ohm/1000ft |
| Operating Temperature | -30°C to +105°C (UL Temperature: 105°C) |
| Overall Cable Diameter (Nominal) | 0.236 in (5.99 mm) |
| UL Voltage Rating | 300 V (PLTC, CMG) |