1093A Datasheet
The Belden 1093A is a UL-listed instrumentation cable featuring four 18 AWG bare copper triads with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF applications, with a maximum operating temperature of 90°C dry and wet. This cable is designed for industrial control, DCS, PLC systems, and low-voltage digital control circuits in instruments, solenoids, valves, and actuators.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1093A Key Specifications
- Max. Current
- 7 Amps per Conductor at 25°C
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Operating Temperature
- -30°C to 90°C Wet/Dry (UL 90°C Dry, 90°C Wet)
- Bulk Cable Weight
- 181 lbs/1000ft
- Conductor
- 4 Triad 18 AWG (7x26) Bare Copper
- Max. Pull Tension
- 347 lbs (157 kg)
- Nom. Conductor DCR
- 6.79 Ohm/1000ft
- Outer Jacket
- Black PVC, 0.064 in (1.6 mm) thickness, 0.583 in nominal diameter
Characteristics (datasheet)
- Conductor
- 4 Triad 18 AWG (7x26) Bare Copper
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Max. Current
- 7 Amps per Conductor at 25°C
- Nom. Conductor DCR
- 6.79 Ohm/1000ft
- Operating Temperature
- -30°C to 90°C Wet/Dry (UL 90°C Dry, 90°C Wet)
- Outer Jacket
- Black PVC, 0.064 in (1.6 mm) thickness, 0.583 in nominal diameter
- Max. Pull Tension
- 347 lbs (157 kg)
- Bulk Cable Weight
- 181 lbs/1000ft
1093A Applications
- Industrial Control
- Raceways, cable trays and ducts
- Digital Control
- Instruments (4-20ma, 0-10v)
- Low voltage digital control (24v)
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids, Valves, actuators, positioners
Other Belden parts
- 2178A — The 2178A is a discontinued miniature bundled 16-coaxial cable featuring 23 AWG...
- 79007 — The Belden 79007 is a flexible 12-conductor 20 AWG tinned copper cable featuring...
- 1505A — The Belden 1505A is a 75 Ohm SDI coaxial cable of RG-59 type, built with a 20 AW...
- 5026C — The Belden 5026C (branded as Alpha Wire) is a multi-conductor instrumentation ca...
- 3125A — The Belden 3125A is a DeviceBus® multi-pair cable designed for Square D/Seriplex...
- 930103102 — HIRSCHMANN TEST AND MEASUREMENT 930103102 SOCKET, 4MM, BLUE, PK5, MLS
- 8261 — The Belden 8261 is an RG11 analog video coaxial cable designed for SDI coax appl...
- 78034 — The Belden 78034 is a 4-conductor, 22 AWG tinned copper ECOCABLE with modified p...
More Bulk Wire Cable
- 45008 — The Belden 45008 is an 8-conductor, 22 AWG (7x30 stranded) tinned copper cable w...
- 84142 — The Belden 84142 is a commercial, non-QPL mil-spec coaxial cable (RG-142) with a...
- 77105 — The Belden 77105 is a 5-conductor, 24 AWG tinned copper cable with mPPE insulati...
- 1070A — The Belden 1070A is a UL-listed multi-conductor instrumentation and control cabl...
- 35610 — The Belden 35610 is a 10 AWG (65x28) stranded tinned copper lead wire with XLP/X...
- 7987P — The Belden 7987P is a NanoSkew™ cable consisting of four 24 AWG solid bare coppe...
- 45494 — Belden part 45494 is an XTRAGUARD 4 cable containing four shielded 24 AWG (7x32)...
- 7130 — The Belden 7130 is a single-conductor hook-up wire featuring a 24 AWG tinned cop...
1093A FAQ
What is 1093A?
1093A is a Bulk Wire Cable from Belden. The Belden 1093A is a UL-listed instrumentation cable featuring four 18 AWG bare copper triads with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF applications, with a maximum operating temperature of 90°C dry and wet. This cable is designed for industrial control, DCS, PLC systems, and low-voltage digital control circuits in instruments, solenoids, valves, and actuators.
Who manufactures 1093A?
1093A is manufactured by Belden.
Where can I download the 1093A datasheet PDF?
The 1093A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1093A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 181 lbs/1000ft |
| Conductor | 4 Triad 18 AWG (7x26) Bare Copper |
| Max. Current | 7 Amps per Conductor at 25°C |
| Max. Pull Tension | 347 lbs (157 kg) |
| Nom. Conductor DCR | 6.79 Ohm/1000ft |
| Operating Temperature | -30°C to 90°C Wet/Dry (UL 90°C Dry, 90°C Wet) |
| Outer Jacket | Black PVC, 0.064 in (1.6 mm) thickness, 0.583 in nominal diameter |
| Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |