The Belden 9392 is a high-performance instrumentation cable consisting of 15 pairs of 18 AWG stranded tinned copper conductors, individually shielded with Beldfoil and insulated in PVC, all enclosed in a PVC outer jacket. It is rated for 300V PLTC use with an operating temperature range of -30°C to +105°C. This cable is designed for industrial applications such as instrumentation, sensors, valves, positioners, and transmitting 4-20mA and 0-10V signals.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
9392 Key Specifications
- Max. Current
- 7 Amps per Conductor at 25°C
- Nom. Capacitance Cond-to-Cond
- 61 pF/ft (200 pF/m)
- Nom. Capacitance Cond-to-Other
- 112 pF/ft (367 pF/m)
- Nom. Inductance
- 0.18 µH/ft (0.59 µH/m)
- UL Voltage Rating
- 300 V (PLTC)
- Operating Temperature
- -30°C To +105°C (UL Temperature 105°C)
- Bulk Cable Weight
- 368 lbs/1000ft
- Conductor
- 15 pairs, 18 AWG (19x30) Tinned Copper (TC)
Characteristics (datasheet)
- Conductor
- 15 pairs, 18 AWG (19x30) Tinned Copper (TC)
- Nom. Conductor DCR
- 7.19 Ohm/1000ft
- Nom. Inner Shield DCR
- 0.5 Ohm/1000ft (1.6 Ohm/km)
- Nom. Capacitance Cond-to-Cond
- 61 pF/ft (200 pF/m)
- Nom. Capacitance Cond-to-Other
- 112 pF/ft (367 pF/m)
- Nom. Inductance
- 0.18 µH/ft (0.59 µH/m)
- Max. Current
- 7 Amps per Conductor at 25°C
- UL Voltage Rating
- 300 V (PLTC)
- Operating Temperature
- -30°C To +105°C (UL Temperature 105°C)
- Max. Pull Tension
- 966 lbs (438 kg)
- Bulk Cable Weight
- 368 lbs/1000ft
9392 Applications
- Instrumentation
- Sensors
- Valves
- Positioners
Other Belden parts
- 35372 — Belden part 35372 is an XTRAGUARD 3 cable with two pairs of 18 AWG (16x30) stran...
- 25102 — Belden part 25102 is an XTRAGUARD 2 two-conductor cable built with 22 AWG (7x30)...
- 58134 — The Belden 58134 is a plenum-rated, overall shielded 4-conductor 18 AWG bare cop...
- 8790 — The Belden 8790 is a line level audio cable designed for low voltage analog sign...
- 5311C — The 5311C is an XTRAGUARD 1 shielded multi-conductor cable featuring 7 conductor...
- 3073 — The Belden 3073 is a single-conductor 20 AWG tinned copper hook-up wire with PVC...
- 9248 — The Belden 9248 is a 75 Ohm RG-6 analog video coaxial cable featuring an 18 AWG...
- 5383C — The 5383C is a 3-conductor, 18 AWG tinned copper shielded cable with PVC insulat...
More Bulk Wire Cable
- 1538A — The 1538A is a RISC 6000 IBM N cable featuring three 28 AWG stranded bare copper...
- 6549PA — The Belden 6549PA is a discontinued, plenum-rated multi-pair cable designed for...
- 21640 — The Belden 21640 is a CSA Tray TC-CIC 600 V cable with 42 conductors of 10 AWG (...
- 3093A — The 3093A is a high-performance ControlBus™ coaxial cable (RG-6, 18 AWG solid ba...
- 1751 — The Belden 1751 is a 3-conductor 14 AWG tinned copper control and communication...
- 78134 — The Belden 78134 is a 4-conductor 22 AWG stranded tinned copper ECOCABLE featuri...
- 55273 — The part 55273 is an XTRAGUARD 5 shielded cable featuring three pairs of 24 AWG...
- 45470 — Belden part 45470 is an XTRAGUARD 4 cable with 10 conductors of 20 AWG (7x28) ti...
9392 FAQ
What is 9392?
9392 is a Bulk Wire Cable from Belden. The Belden 9392 is a high-performance instrumentation cable consisting of 15 pairs of 18 AWG stranded tinned copper conductors, individually shielded with Beldfoil and insulated in PVC, all enclosed in a PVC outer jacket. It is rated for 300V PLTC use with an operating temperature range of -30°C to +105°C. This cable is designed for industrial applications such as instrumentation, sensors, valves, positioners, and transmitting 4-20mA and 0-10V signals.
Who manufactures 9392?
9392 is manufactured by Belden.
Where can I download the 9392 datasheet PDF?
The 9392 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 9392 specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 368 lbs/1000ft |
| Conductor | 15 pairs, 18 AWG (19x30) Tinned Copper (TC) |
| Max. Current | 7 Amps per Conductor at 25°C |
| Max. Pull Tension | 966 lbs (438 kg) |
| Nom. Capacitance Cond-to-Cond | 61 pF/ft (200 pF/m) |
| Nom. Capacitance Cond-to-Other | 112 pF/ft (367 pF/m) |
| Nom. Conductor DCR | 7.19 Ohm/1000ft |
| Nom. Inductance | 0.18 µH/ft (0.59 µH/m) |
| Nom. Inner Shield DCR | 0.5 Ohm/1000ft (1.6 Ohm/km) |
| Operating Temperature | -30°C To +105°C (UL Temperature 105°C) |
| UL Voltage Rating | 300 V (PLTC) |