9392 Datasheet

BeldenBulk Wire Cable

The Belden 9392 is a high-performance instrumentation cable consisting of 15 pairs of 18 AWG stranded tinned copper conductors, individually shielded with Beldfoil and insulated in PVC, all enclosed in a PVC outer jacket. It is rated for 300V PLTC use with an operating temperature range of -30°C to +105°C. This cable is designed for industrial applications such as instrumentation, sensors, valves, positioners, and transmitting 4-20mA and 0-10V signals.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

9392 Key Specifications

Max. Current
7 Amps per Conductor at 25°C
Nom. Capacitance Cond-to-Cond
61 pF/ft (200 pF/m)
Nom. Capacitance Cond-to-Other
112 pF/ft (367 pF/m)
Nom. Inductance
0.18 µH/ft (0.59 µH/m)
UL Voltage Rating
300 V (PLTC)
Operating Temperature
-30°C To +105°C (UL Temperature 105°C)
Bulk Cable Weight
368 lbs/1000ft
Conductor
15 pairs, 18 AWG (19x30) Tinned Copper (TC)

Characteristics (datasheet)

Conductor
15 pairs, 18 AWG (19x30) Tinned Copper (TC)
Nom. Conductor DCR
7.19 Ohm/1000ft
Nom. Inner Shield DCR
0.5 Ohm/1000ft (1.6 Ohm/km)
Nom. Capacitance Cond-to-Cond
61 pF/ft (200 pF/m)
Nom. Capacitance Cond-to-Other
112 pF/ft (367 pF/m)
Nom. Inductance
0.18 µH/ft (0.59 µH/m)
Max. Current
7 Amps per Conductor at 25°C
UL Voltage Rating
300 V (PLTC)
Operating Temperature
-30°C To +105°C (UL Temperature 105°C)
Max. Pull Tension
966 lbs (438 kg)
Bulk Cable Weight
368 lbs/1000ft

9392 Applications

  • Instrumentation
  • Sensors
  • Valves
  • Positioners

Other Belden parts

  • 35372 — Belden part 35372 is an XTRAGUARD 3 cable with two pairs of 18 AWG (16x30) stran...
  • 25102 — Belden part 25102 is an XTRAGUARD 2 two-conductor cable built with 22 AWG (7x30)...
  • 58134 — The Belden 58134 is a plenum-rated, overall shielded 4-conductor 18 AWG bare cop...
  • 8790 — The Belden 8790 is a line level audio cable designed for low voltage analog sign...
  • 5311C — The 5311C is an XTRAGUARD 1 shielded multi-conductor cable featuring 7 conductor...
  • 3073 — The Belden 3073 is a single-conductor 20 AWG tinned copper hook-up wire with PVC...
  • 9248 — The Belden 9248 is a 75 Ohm RG-6 analog video coaxial cable featuring an 18 AWG...
  • 5383C — The 5383C is a 3-conductor, 18 AWG tinned copper shielded cable with PVC insulat...

More Bulk Wire Cable

  • 1538A — The 1538A is a RISC 6000 IBM N cable featuring three 28 AWG stranded bare copper...
  • 6549PA — The Belden 6549PA is a discontinued, plenum-rated multi-pair cable designed for...
  • 21640 — The Belden 21640 is a CSA Tray TC-CIC 600 V cable with 42 conductors of 10 AWG (...
  • 3093A — The 3093A is a high-performance ControlBus™ coaxial cable (RG-6, 18 AWG solid ba...
  • 1751 — The Belden 1751 is a 3-conductor 14 AWG tinned copper control and communication...
  • 78134 — The Belden 78134 is a 4-conductor 22 AWG stranded tinned copper ECOCABLE featuri...
  • 55273 — The part 55273 is an XTRAGUARD 5 shielded cable featuring three pairs of 24 AWG...
  • 45470 — Belden part 45470 is an XTRAGUARD 4 cable with 10 conductors of 20 AWG (7x28) ti...

9392 FAQ

What is 9392?

9392 is a Bulk Wire Cable from Belden. The Belden 9392 is a high-performance instrumentation cable consisting of 15 pairs of 18 AWG stranded tinned copper conductors, individually shielded with Beldfoil and insulated in PVC, all enclosed in a PVC outer jacket. It is rated for 300V PLTC use with an operating temperature range of -30°C to +105°C. This cable is designed for industrial applications such as instrumentation, sensors, valves, positioners, and transmitting 4-20mA and 0-10V signals.

Who manufactures 9392?

9392 is manufactured by Belden.

Where can I download the 9392 datasheet PDF?

The 9392 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 9392 specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk Cable Weight368 lbs/1000ft
Conductor15 pairs, 18 AWG (19x30) Tinned Copper (TC)
Max. Current7 Amps per Conductor at 25°C
Max. Pull Tension966 lbs (438 kg)
Nom. Capacitance Cond-to-Cond61 pF/ft (200 pF/m)
Nom. Capacitance Cond-to-Other112 pF/ft (367 pF/m)
Nom. Conductor DCR7.19 Ohm/1000ft
Nom. Inductance0.18 µH/ft (0.59 µH/m)
Nom. Inner Shield DCR0.5 Ohm/1000ft (1.6 Ohm/km)
Operating Temperature-30°C To +105°C (UL Temperature 105°C)
UL Voltage Rating300 V (PLTC)