5383C Datasheet

BeldenBulk Wire Cable

The 5383C is a 3-conductor, 18 AWG tinned copper shielded cable with PVC insulation and a slate PVC outer jacket, rated for a voltage of 300 V and operating temperatures from -30°C to +105°C. It features an overall bi-laminate aluminum/polyester shield with a TC drain wire to protect signal integrity. It is designed for use in industrial control systems, instrumentation and control circuits, PLC and DCS systems, and sensor/actuator applications.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

5383C Key Specifications

Nom. Capacitance Cond-to-Cond
45 pF/ft (150 pF/m)
Nom. Capacitance Cond-to-Other
81 pF/ft (270 pF/m)
Nom. Inductance
0.18 µH/ft (0.59 µH/m)
Voltage Rating
300 V (CMG, CM, AWM 2464, AWM 2517)
Operating Temperature
-30°C To +105°C (UL Temperature 105°C)
Conductors
3 elements, 18 AWG 16x30 TC - Tinned Copper
Max. Pull Tension
16.5 lbs (7.48 kg)
Min. Bend Radius (Stationary)
2.4 in (61 mm)

Characteristics (datasheet)

Conductors
3 elements, 18 AWG 16x30 TC - Tinned Copper
Voltage Rating
300 V (CMG, CM, AWM 2464, AWM 2517)
Operating Temperature
-30°C To +105°C (UL Temperature 105°C)
Outer Shield
Tape Bi-Laminate (Alum+Poly) 100% Coverage, 18 AWG (16x30) TC drainwire
Outer Jacket
PVC - Polyvinyl Chloride, 0.032 in (0.81 mm) thickness
Nominal Outer Diameter
0.242 in (6.15 mm)
Nom. Capacitance Cond-to-Cond
45 pF/ft (150 pF/m)
Nom. Capacitance Cond-to-Other
81 pF/ft (270 pF/m)
Nom. Inductance
0.18 µH/ft (0.59 µH/m)
Outer Shield DCR
6 Ohm/1000ft (20 Ohm/km)
Min. Bend Radius (Stationary)
2.4 in (61 mm)
Max. Pull Tension
16.5 lbs (7.48 kg)

5383C Applications

  • Industrial control systems, raceways, cable trays, and ducts
  • Instrumentation and control circuits
  • Analog and digital signals (4–20 mA, 0–10 V)
  • PLC and DCS systems
  • Sensors, encoders, solenoids, valves, actuators, and positioners

Other Belden parts

  • 45093 — The Belden 45093 is an XTRAGUARD 4 3-conductor cable built with 24 AWG (7x32) ti...
  • 79220 — The Belden 79220 ECOFLEX is a 4-conductor, 16 AWG tinned copper cable with mPPE...
  • 6360 — The Belden 6360 is a 25-conductor shielded communication and control cable desig...
  • 8012 — The Belden 8012 is a bus bar wire featuring a 14 AWG solid tinned copper conduct...
  • 6643 — The Belden 6643 is a 3-conductor communication and control cable featuring 20 AW...
  • 72402 — The Belden 72402 is a high-temperature control cable with two 24 AWG silver-plat...
  • 7415W — The 7415W is a MachFlex™ high-flexibility cable featuring 11 conductors plus 1 g...
  • 930126101 — HIRSCHMANN TEST AND MEASUREMENT 930126101 CROCODILE CLIP, 6MM, GREY/RED, 6A

More Bulk Wire Cable

  • 57006 — The Belden 57006 is a plenum-rated, 6-conductor 24 AWG bare copper communication...
  • 78005 — The Belden 78005 is a multi-conductor ECOCABLE consisting of 5 pairs of 28 AWG t...
  • 6823 — The Belden 6823 is a single-conductor hook-up wire featuring a 22 AWG bare coppe...
  • 6500FC — The Belden 6500FC is a plenum-rated security, pro audio, and intercom cable feat...
  • 9273 — The Belden 9273 is a commercial, non-QPL Mil-Spec coaxial cable with a 50 Ohm ch...
  • 30816 — Belden part 30816 is a 16 AWG (26x30) stranded tinned copper lead wire with sili...
  • 79052 — The Belden 79052 is a 4-conductor, 24 AWG tinned copper cable with modified poly...
  • 58414 — The Belden 58414 is a plenum-rated, overall shielded communication and control c...

5383C FAQ

What is 5383C?

5383C is a Bulk Wire Cable from Belden. The 5383C is a 3-conductor, 18 AWG tinned copper shielded cable with PVC insulation and a slate PVC outer jacket, rated for a voltage of 300 V and operating temperatures from -30°C to +105°C. It features an overall bi-laminate aluminum/polyester shield with a TC drain wire to protect signal integrity. It is designed for use in industrial control systems, instrumentation and control circuits, PLC and DCS systems, and sensor/actuator applications.

Who manufactures 5383C?

5383C is manufactured by Belden.

Where can I download the 5383C datasheet PDF?

The 5383C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 5383C specifications

AI Powered

Click to ask a quick question:

Parameters

Conductors3 elements, 18 AWG 16x30 TC - Tinned Copper
Max. Pull Tension16.5 lbs (7.48 kg)
Min. Bend Radius (Stationary)2.4 in (61 mm)
Nom. Capacitance Cond-to-Cond45 pF/ft (150 pF/m)
Nom. Capacitance Cond-to-Other81 pF/ft (270 pF/m)
Nominal Outer Diameter0.242 in (6.15 mm)
Nom. Inductance0.18 µH/ft (0.59 µH/m)
Operating Temperature-30°C To +105°C (UL Temperature 105°C)
Outer JacketPVC - Polyvinyl Chloride, 0.032 in (0.81 mm) thickness
Outer ShieldTape Bi-Laminate (Alum+Poly) 100% Coverage, 18 AWG (16x30) TC drainwire
Outer Shield DCR6 Ohm/1000ft (20 Ohm/km)
Voltage Rating300 V (CMG, CM, AWM 2464, AWM 2517)