5383C Datasheet
The 5383C is a 3-conductor, 18 AWG tinned copper shielded cable with PVC insulation and a slate PVC outer jacket, rated for a voltage of 300 V and operating temperatures from -30°C to +105°C. It features an overall bi-laminate aluminum/polyester shield with a TC drain wire to protect signal integrity. It is designed for use in industrial control systems, instrumentation and control circuits, PLC and DCS systems, and sensor/actuator applications.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
5383C Key Specifications
- Nom. Capacitance Cond-to-Cond
- 45 pF/ft (150 pF/m)
- Nom. Capacitance Cond-to-Other
- 81 pF/ft (270 pF/m)
- Nom. Inductance
- 0.18 µH/ft (0.59 µH/m)
- Voltage Rating
- 300 V (CMG, CM, AWM 2464, AWM 2517)
- Operating Temperature
- -30°C To +105°C (UL Temperature 105°C)
- Conductors
- 3 elements, 18 AWG 16x30 TC - Tinned Copper
- Max. Pull Tension
- 16.5 lbs (7.48 kg)
- Min. Bend Radius (Stationary)
- 2.4 in (61 mm)
Characteristics (datasheet)
- Conductors
- 3 elements, 18 AWG 16x30 TC - Tinned Copper
- Voltage Rating
- 300 V (CMG, CM, AWM 2464, AWM 2517)
- Operating Temperature
- -30°C To +105°C (UL Temperature 105°C)
- Outer Shield
- Tape Bi-Laminate (Alum+Poly) 100% Coverage, 18 AWG (16x30) TC drainwire
- Outer Jacket
- PVC - Polyvinyl Chloride, 0.032 in (0.81 mm) thickness
- Nominal Outer Diameter
- 0.242 in (6.15 mm)
- Nom. Capacitance Cond-to-Cond
- 45 pF/ft (150 pF/m)
- Nom. Capacitance Cond-to-Other
- 81 pF/ft (270 pF/m)
- Nom. Inductance
- 0.18 µH/ft (0.59 µH/m)
- Outer Shield DCR
- 6 Ohm/1000ft (20 Ohm/km)
- Min. Bend Radius (Stationary)
- 2.4 in (61 mm)
- Max. Pull Tension
- 16.5 lbs (7.48 kg)
5383C Applications
- Industrial control systems, raceways, cable trays, and ducts
- Instrumentation and control circuits
- Analog and digital signals (4–20 mA, 0–10 V)
- PLC and DCS systems
- Sensors, encoders, solenoids, valves, actuators, and positioners
Other Belden parts
- 45093 — The Belden 45093 is an XTRAGUARD 4 3-conductor cable built with 24 AWG (7x32) ti...
- 79220 — The Belden 79220 ECOFLEX is a 4-conductor, 16 AWG tinned copper cable with mPPE...
- 6360 — The Belden 6360 is a 25-conductor shielded communication and control cable desig...
- 8012 — The Belden 8012 is a bus bar wire featuring a 14 AWG solid tinned copper conduct...
- 6643 — The Belden 6643 is a 3-conductor communication and control cable featuring 20 AW...
- 72402 — The Belden 72402 is a high-temperature control cable with two 24 AWG silver-plat...
- 7415W — The 7415W is a MachFlex™ high-flexibility cable featuring 11 conductors plus 1 g...
- 930126101 — HIRSCHMANN TEST AND MEASUREMENT 930126101 CROCODILE CLIP, 6MM, GREY/RED, 6A
More Bulk Wire Cable
- 57006 — The Belden 57006 is a plenum-rated, 6-conductor 24 AWG bare copper communication...
- 78005 — The Belden 78005 is a multi-conductor ECOCABLE consisting of 5 pairs of 28 AWG t...
- 6823 — The Belden 6823 is a single-conductor hook-up wire featuring a 22 AWG bare coppe...
- 6500FC — The Belden 6500FC is a plenum-rated security, pro audio, and intercom cable feat...
- 9273 — The Belden 9273 is a commercial, non-QPL Mil-Spec coaxial cable with a 50 Ohm ch...
- 30816 — Belden part 30816 is a 16 AWG (26x30) stranded tinned copper lead wire with sili...
- 79052 — The Belden 79052 is a 4-conductor, 24 AWG tinned copper cable with modified poly...
- 58414 — The Belden 58414 is a plenum-rated, overall shielded communication and control c...
5383C FAQ
What is 5383C?
5383C is a Bulk Wire Cable from Belden. The 5383C is a 3-conductor, 18 AWG tinned copper shielded cable with PVC insulation and a slate PVC outer jacket, rated for a voltage of 300 V and operating temperatures from -30°C to +105°C. It features an overall bi-laminate aluminum/polyester shield with a TC drain wire to protect signal integrity. It is designed for use in industrial control systems, instrumentation and control circuits, PLC and DCS systems, and sensor/actuator applications.
Who manufactures 5383C?
5383C is manufactured by Belden.
Where can I download the 5383C datasheet PDF?
The 5383C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 5383C specifications
Click to ask a quick question:
Parameters
| Conductors | 3 elements, 18 AWG 16x30 TC - Tinned Copper |
| Max. Pull Tension | 16.5 lbs (7.48 kg) |
| Min. Bend Radius (Stationary) | 2.4 in (61 mm) |
| Nom. Capacitance Cond-to-Cond | 45 pF/ft (150 pF/m) |
| Nom. Capacitance Cond-to-Other | 81 pF/ft (270 pF/m) |
| Nominal Outer Diameter | 0.242 in (6.15 mm) |
| Nom. Inductance | 0.18 µH/ft (0.59 µH/m) |
| Operating Temperature | -30°C To +105°C (UL Temperature 105°C) |
| Outer Jacket | PVC - Polyvinyl Chloride, 0.032 in (0.81 mm) thickness |
| Outer Shield | Tape Bi-Laminate (Alum+Poly) 100% Coverage, 18 AWG (16x30) TC drainwire |
| Outer Shield DCR | 6 Ohm/1000ft (20 Ohm/km) |
| Voltage Rating | 300 V (CMG, CM, AWM 2464, AWM 2517) |