80PT-25 Datasheet

DanaherSensor

Insertion measuring sensor type T, -196. . .+350°C, 80PT-25, Fluke

The 80PT-25 is a Type T (Copper/Constantan) piercing temperature probe with a 316 stainless steel sheath, designed for use in liquids, gels, soft, and semi-hard materials. It has a measurement range of -196 °C to 350 °C and connects to compatible instruments via a miniature thermocouple connector. The probe is suitable for food service applications within specified temperature and material limitations. The datasheet contains some inconsistencies, mentioning compatibility with both Type T and Type K instruments in different sections. The absolute maximum ratings table is not present in the provided text. The device has no marking code, applications, or package information listed in the text. The pin table is not provided as the device uses a standard connector rather than numbered pins. The operating temperature range is not explicitly stated as a separate specification, though measurement and limitation ranges are given. The physical dimensions and materials of the sheath, cable, handle, and connector are detailed. The troubleshooting section provides steps for verifying instrument compatibility and probe continuity. Scale conversions between Celsius and Fahrenheit are included. Contact information for Fluke and a one-year limited warranty are also provided. The document includes a figure illustrating the probe's dimensions and tip style. The instruction sheet covers introduction, specifications, measurement considerations, operation, measuring technique, troubleshooting, scale conversions, contacting Fluke, and warranty information. The text is formatted with tables for accuracy specifications and includes notes on error calculations and food service limitations. The document is copyrighted by Fluke Corporation and includes trademarks and product names of respective companies. The instruction sheet is dated November 2004 and includes a warning about electrical shock hazards when using the probe with voltages exceeding 24 V ac rms or 60 V dc. The probe tip is electronically connected to the output terminals, posing a shock risk. The maximum temperature of the tip is 816 °C (1500 °F), while the handle and cable have lower temperature limits. The probe should not be exposed to halides or sulfides due to the stainless steel sheath. The food service limitations specify conditions for repeat food contact, including temperature, alcohol content, and food type. The cable should not come into contact with food. The overall probe length is 22.23 cm (8.75 in) from tip to end of cable strain relief. The protection class is 3, relating to insulation and grounding properties defined in IEC 348. The sheath has a 25 ° conical tip and a grounding junction welded to the sheath. The cable is 40 inches (1 meter) long with PVC insulation and a gray jacket. The conductors are Type T, AWG #24 stranded (7 strands of #32). The handle is made of Hytrel (food service grade) with a maximum food contact temperature of 65 °C (150 °F). The connector is a blue Hytrel (food service grade) mini-thermocouple connector with a maximum temperature of 125 °C (257 °F). The measurement considerations section discusses instrument compatibility, temperature limitations, exposure limitations, and food service limitations. The operation section provides steps for using the probe, including connecting to a compatible instrument, turning it on, and checking the readout. The measuring technique recommends inserting the probe at least 31.75 mm (1.25 in) into the substance to minimize the shunting effect. The troubleshooting section includes steps for verifying instrument compatibility, checking for open circuit indicators, shorting input pins, and using an ohmmeter to check continuity. The scale conversions section provides equations for converting between Celsius and Fahrenheit. The contacting Fluke section provides phone numbers and a website for application or operation assistance. The warranty section outlines the one-year limited warranty, excluding fuses, disposable batteries, and damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty. The warranty is the only remedy, and no other warranties are expressed or implied. Fluke is not liable for any special, indirect, incidental, or consequential damages or losses. The limitation of liability may not apply in some states or countries. The document includes addresses for Fluke Corporation and Fluke Europe B.V. The instruction sheet is dated 11/99 and includes a figure illustrating the probe's dimensions and tip style. The figure shows a 4

Download PDF

80PT-25 Key Specifications

DC Rated Voltage
60V
Voltage Rating
60V
Length
8.75inch

Characteristics (datasheet)

Type
T, Copper/Constantan
Measurement Range of Stainless Steel Probe
-196 °C to 350 °C (-320.8 °F to 662 °F)
Accuracy (0 °C to 350 °C)
Max (±1 °C, ±0.75 % of reading)
Output @ 25 °C
1.00 mV (reference junction at 0 °C)
Seebeck Coefficient @ 25 °C
40.50 µV / °C
Measurement Time (Time Constant)
3.0 seconds in 100 °C still water
Maximum Voltage
24 V ac rms or 60 V dc
Sheath Material
316 Stainless Steel

Other Danaher parts

  • 80PK-EXT — 1 pair of type K connectors (socket/plug), 3m, 80PK-EXT, Fluke
  • NFK1-SMPLX-ST — FLUKE NETWORKS NFK1-SMPLX-ST 62.5 UM SC/ST TRC SET
  • FLUKE-700G02 — 700G02 Digi Positive Press Gauge 70mbar1/4 NPTin, Interface Type RS232 FLUKE 700
  • FLUKE-190-502/AM/S — SCOPEMETER 2CH 500MHZ COLOR SCC
  • DPO3FLEX — TEKTRONIX DPO3FLEX Oscilloscope Module, FlexRay Serial Trigg...
  • AFG3101 — Arbitrary u0026 DDS Signal Generator, 100MHz Bandwidth, 2-Channel, USB Interface
  • AFG3011C — TEKTRONIX AFG3011C FUNCTION GENERATOR, ARB, 1 CH, 10MHZ
  • FLUKE-124/003 — INDUSTRIAL SCOPEMETER 40MHZ

More Test Accessories

  • 934061103 — HIRSCHMANN TEST AND MEASUREMENT 934061103 Test Lead, 4mm Bana...
  • 934074101 — 1kV 16A Test Probe Lead, Nickel Plated, 1m Length, PA Material
  • 931376100 — HIRSCHMANN TEST AND MEASUREMENT 931376100 PROBE, TEST, MINIATURE, MLS
  • 934059102 — Blue 60V 32A 250mm Test Probe Lead
  • 973647100 — HIRSCHMANN TEST AND MEASUREMENT 973647100 Test Lead, 4mm Banana Plug to 4mm...
  • 934060100 — 60V 16A Black Insulated Cable Plug, 500mm Long, -15°C to 70°C
  • 934073100 — HIRSCHMANN TEST AND MEASUREMENT 934073100 Test Lead, 4mm Banana Plug to 4mm...
  • SPC12055 — Connector assemblies, Test; Lead Length: 1ft; Insulator Color: Black; Cable Leng...

80PT-25 FAQ

What is 80PT-25?

80PT-25 is a Sensor from Danaher. Insertion measuring sensor type T, -196. . .+350°C, 80PT-25, Fluke.

Who manufactures 80PT-25?

80PT-25 is manufactured by Danaher.

Where can I download the 80PT-25 datasheet PDF?

The 80PT-25 datasheet PDF (262 KB) can be downloaded free from this page using the Download PDF button.

Specifications

Manufacturer
Danaher
File Size
262 KB

Ask AI Assistant

Ask questions about 80PT-25 specifications

AI Powered

Click to ask a quick question:

Parameters

ColorGrey
DC Rated Voltage60V
Length8.75inch
PackagingBulk
Reach SVHC CompliantNo
RoHSCompliant
SeriesSureGrip™ 80
Voltage Rating60V