AFG3011C Key Specifications

Bandwidth
10MHz
Frequency
10MHz
Max Frequency
10MHz
Max Supply Voltage
240V
Min Supply Voltage
100V
Number of Channels
1
Max Operating Temperature
50°C
Min Operating Temperature
0°C

Characteristics (datasheet)

Channels
1
Sine Wave
1 µHz to 10 MHz
Sine wave in Burst Mode
1 µHz to 5 MHz
Effective maximum frequency out
10 MHz
Amplitude Flatness (1 Vp-p)
<5 MHz: ±0.15 dB, ≥5 MHz to 10 MHz: ±0.3 dB
Harmonic Distortion (1 Vp-p)
10 Hz to 20 kHz: < -60 dBc, ≥20 kHz to 1 MHz: < -55 dBc, ≥1 MHz to 5 MHz: < -45 dBc, ≥5 MHz to 10 MHz: < -45 dBc
Spurious (1 Vp-p)
10 Hz to 1 MHz: < -60 dBc, ≥1 MHz to 10 MHz: < -50 dBc
Residual clock noise
-63 dBm
Square Wave
1 µHz to 5 MHz
Rise/Fall time
≤50 ns
Jitter (RMS), typical
500 ps
Ramp Wave
1 µHz to 100 kHz
Linearity, typical
≤0.2% of peak output
Pulse Wave
1 mHz to 5 MHz
Edge transition time
50 ns to 625 s
Other Waveforms
1 µHz to 100 kHz
DC (into 50 Ω)
-10 V to +10 V
Arbitrary Waveforms
1 mHz to 5 MHz
Arbitrary waveforms in Burst Mode
1 mHz to 2.5 MHz
Memory: Sample rate
2 to 128 K: 250 MS/s
Vertical resolution
14 bits
Rise/Fall time (Arbitrary)
≤80 ns
Jitter (RMS), typical (Arbitrary)
4 ns
Amplitude Range (50 Ω load)
20 mVp-p to 20 Vp-p
Range (open circuit or High Z)
40 mVp-p to 40 Vp-p
Accuracy
±
DC Offset Range (50 Ω load)
±(10 Vpk – Amplitudepp/2)
Range (open circuit or High Z) (DC Offset)
±(20 Vpk – Amplitudepp/2)
DC Offset Accuracy
±)
Weight Net
4.5 kg (9.9 lb.)
Weight Shipping
5.9 kg (12.9 lb.)

Other Danaher parts

  • FLUKE-322 — MULTIMETER, CLAMP, 400A FLUKE 322
  • FLUKE-700PD6 — Calibration Equipment PRESSURE MODULE -15+100PSIG
  • 80CJ-M — TEST CONNECTOR; For Use With:J Type Thermocouples ;RoHS Compliant: NA
  • FLUKE-353 — Clamp Multimeters u0026 Accessories AC/DC TRMS CLAMP - METER 2000A
  • TDS2001C — OSCILLOSCOPE, 2CH, 50MHZ, 500MSPS
  • C10 — Test Accessories - Other HOLSTER
  • TAS90 — Test Probes Shielded Test Lead Accessory Set
  • 19800003 — TS19 TEST SET BANANA JACK TO GTR

More Test Equipment

  • N8758A — KEYSIGHT TECHNOLOGIES N8758A POWER SUPPLY, 1CH, 80V, 65A, FI...
  • PG-100N-101R-H — HANDHELD DIGITAL MANOMETER
  • TPI153 — Dmm Auto-range 4DIGIT
  • TM-700I — Greenlee TM-700I, Telecom Test Equipment supplied with Crocodile Clips
  • 34905A — KEYSIGHT TECHNOLOGIES 34905A Dual 4 Channel RF Multiplexer wi...
  • 1785 — Bench Top Power Supplies
  • 2001-290 — MEGGER 2001-290 EXTENSION LEAD ADAPTOR
  • 407736-NIST — Audio/Video Test Equipment SOUND METER WITH N

AFG3011C FAQ

What is AFG3011C?

AFG3011C is a Test Equipment from Danaher. TEKTRONIX AFG3011C FUNCTION GENERATOR, ARB, 1 CH, 10MHZ.

Who manufactures AFG3011C?

AFG3011C is manufactured by Danaher.

What is the operating temperature range of AFG3011C?

AFG3011C operates from 0°C to 50°C.

Where can I download the AFG3011C datasheet PDF?

The AFG3011C datasheet PDF (324 KB) can be downloaded free from this page using the Download PDF button.

What are the equivalents or alternatives to AFG3011C?

Parts with a similar function (Test Equipment) include AFG3021C, AFG3022C, AFG3051C. Always compare pinout and electrical ratings in both datasheets before substituting.

Specifications

Manufacturer
Danaher
File Size
324 KB

Ask AI Assistant

Ask questions about AFG3011C specifications

AI Powered

Click to ask a quick question:

Parameters

Bandwidth10MHz
Frequency10MHz
Height6.2inch
InterfaceUSB
Length6.6inch
Max Frequency10MHz
Max Operating Temperature50°C
Max Supply Voltage240V
Min Operating Temperature0°C
Min Supply Voltage100V
Number of Channels1
Package Quantity1
PackagingBulk
Reach SVHC CompliantUnknown
RoHSCompliant
Sampling Rate250MS/s
Weight10lb
Width168mm
Wire/Cable TypePower Cord