80I-110S Datasheet
AC/DC Current Clamp 100A, 100kHz Bandwidth, 600V
The Fluke 80i-110s is a clamp-on AC/DC current probe designed to reproduce current waveforms in modern commercial and industrial power distribution systems. It is compatible with millivolt-measuring instruments like oscilloscopes, ScopeMeters, and power harmonic analyzers. The probe is optimized for accurate AC, DC, and AC+DC current measurements up to 100 A peak across electrical, electronic, and automotive applications.
80I-110S Key Specifications
- Bandwidth
- 100kHz
- Current Rating
- 100A
- Voltage Rating (AC)
- 600V
- Max Operating Temperature
- 50°C
- Min Operating Temperature
- 0°C
- Approvals
- UL, CSA, IEC
- Battery Type
- 9V
- Height
- 36mm
Characteristics (datasheet)
- Current Ranges
- 0 to 10A dc or ac peak; 0 to 100A dc or ac peak
- Output Signals
- 10A range: 100 mV/A; 100A range: 10 mV/A
- Basic Accuracy (DC to 1kHz)
- 0 to 10A: <3% of reading +50 mA (100 mV/A); 0 to 40A: <4% of reading +50 mA (10 mV/A); 40 to 80A: <12% of reading +50 mA (10 mV/A); 80 to 100A: <15% of reading (10 mV/A)
- Useful Bandwidth (-3 dB)
- 0 to 100 kHz
- Rise or Fall Time
- <4 Psec.
- Input Load Impedance
- >1 M: in parallel with up to 100 pF.
- Output noise level
- 10 mV/A typ. 480 PV pk-pk; 100 mV/A typ. 3 mV pk-pk
- Temperature coefficient
- 2000 ppm/qC max. for temperature from 0 to 50 qC (32 to 132 qF)
- Battery
- 9 volt battery, type IEC 6LR61
Absolute Maximum Ratings
- Working Voltage (Clamps jaws to Ground)
- 600V ac rms on Installation Category II per IEC 1010-1 circuits; 300V ac rms on Installation Category III per IEC 1010-1 circuits
- Floating Voltage (Output cable and connector to Ground)
- 600V ac rms on Installation Category II per IEC 1010-1 circuits; 300V ac rms on Installation Category III per IEC 1010-1 circuits
- Max. non-destructive current (0 to 2 kHz)
- 140A peak
- Max. non-destructive current (2 to 10 kHz)
- 110A peak
- Max. non-destructive current (10 to 20 kHz)
- 70 A peak
- Max. non-destructive current (20 to 50 kHz)
- 30A peak
- Max. non-destructive current (50 to 100 kHz)
- 20A peak
- Maximum safe circuit rating (CAT II / CAT III)
- 600V in Installation Category II (CAT II) or 300V in Installation Category III (CAT III)
80I-110S Applications
- Electrical, Electronic and Automotive applications
- commercial and industrial power distribution systems
- electronic motor drives and ignition systems
80I-110S Pinout & Package
- Package/Case
- 100
- Mount
- Clamp
The full pin configuration and pin descriptions are in the 80I-110S PDF datasheet above.
Other Danaher parts
- FLUKE-561 — IR Digital Thermometer, -40°C to 1022°C, 1% Acc
- FLUKE-28IIEX/ETL — TRMS MULTIMETER INTRINSICALLY SAFE VERSION OF 28II
- C116 — Instrument Protection and Storage SOFT CARRYING CASE
- FLUKE-700P09EX — Calibration Equipment I.S. PRESSURE MODULE 1500 PSIG
- FLUKE-576-CF — THRM PHTO IR W/LOGNG CLSE FOCUS
- 686527 — Fuse 250 V/125 mA, 686527, Fluke
- PWS4205 — Linear Benchtop Power Supply, 20V 5A, USB Interface, 0-40°C
- FLUKE-700PCK — Calibration Equipment PRESSURE MODULE CALIBRATION KIT
More Test Accessories
- 930126100 — HIRSCHMANN TEST AND MEASUREMENT 930126100 CROCODILE CLIP, 6MM, GREY/BLACK, 6...
- 973368100 — HIRSCHMANN TEST AND MEASUREMENT 973368100 PROBE, TEST, BLACK, 30VAC/60VDC, 4...
- 972337002 — HIRSCHMANN TEST AND MEASUREMENT 972337002 TEST LEAD SET, BLK, RED, 1M, 1KV
- 934066103 — HIRSCHMANN TEST AND MEASUREMENT 934066103 TEST LEAD, YELLOW, 2M, 60V, 32A
- TA044 — PICO TECHNOLOGY TA044 Oscilloscope Probe, 70 MHz, High-Volta...
- 934061709 — HIRSCHMANN TEST AND MEASUREMENT 934061709 Test Lead, 4mm Banana Plug to 4mm...
- 4648-C-48 — Test Leads BNC TO MAXIGRABBE
- SPC12055 — Connector assemblies, Test; Lead Length: 1ft; Insulator Color: Black; Cable Leng...
80I-110S FAQ
What is 80I-110S?
80I-110S is a Test Accessories from Danaher. AC/DC Current Clamp 100A, 100kHz Bandwidth, 600V.
Who manufactures 80I-110S?
80I-110S is manufactured by Danaher.
What package and pinout does 80I-110S have?
80I-110S comes in 100 package, clamp mounting. The pin configuration and pin descriptions are given in the PDF datasheet.
What is the operating temperature range of 80I-110S?
80I-110S operates from 0°C to 50°C.
Where can I download the 80I-110S datasheet PDF?
The 80I-110S datasheet PDF (452 KB) can be downloaded free from this page using the Download PDF button.
Specifications
- Manufacturer
- Danaher
- Category
- Test MeasurementTest Accessories
- File Size
- 452 KB
Ask AI Assistant
Ask questions about 80I-110S specifications
Click to ask a quick question:
Parameters
| Approvals | UL, CSA, IEC |
| Bandwidth | 100kHz |
| Battery Type | 9V |
| Current Rating | 100A |
| Height | 36mm |
| Length | 231mm |
| Max Operating Temperature | 50°C |
| Min Operating Temperature | 0°C |
| Mount | Clamp |
| Package/Case | 100 |
| Package Quantity | 1 |
| Reach SVHC Compliant | No |
| RoHS | Compliant |
| Voltage Rating (AC) | 600V |
| Weight | 330g |
| Width | 67mm |