7129W Datasheet
The Belden 7129W is a MachFlex™ high-flex multi-conductor cable designed for continuous flexing applications such as robotics. It features 24 bare copper conductors plus one ground wire, all insulated with PVC/Nylon and enclosed in a TPE outer jacket. The cable is rated for 1000 V WTTC and 600 V TC-ER, offering excellent resistance to outdoor elements, sunlight, UV, and oil.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
7129W Key Specifications
- Conductor resistance (DCR)
- 4.18 Ohm/1000ft (conductor), 4.45 Ohm/1000ft (ground wire)
- Max. current per conductor
- 11.4 Amps per conductor at 30°C (conductor), 30.4 Amps per conductor at 30°C (ground wire)
- Voltage rating
- 1000 V (WTTC), 600 V (TC-ER)
- Operating temperature
- -40°C To 105°C
- Conductor configuration
- 24+1 Conductor 16AWG (168(7x24) x38) Bare Copper
- Max. pull tension
- 995.7 lbs (451.6 kg)
- Overall cable diameter (nominal)
- 0.8 in
- Stationary min. bend radius
- 3.2 in (81 mm)
Characteristics (datasheet)
- Conductor configuration
- 24+1 Conductor 16AWG (168(7x24) x38) Bare Copper
- Overall cable diameter (nominal)
- 0.8 in
- Voltage rating
- 1000 V (WTTC), 600 V (TC-ER)
- Max. current per conductor
- 11.4 Amps per conductor at 30°C (conductor), 30.4 Amps per conductor at 30°C (ground wire)
- Conductor resistance (DCR)
- 4.18 Ohm/1000ft (conductor), 4.45 Ohm/1000ft (ground wire)
- Operating temperature
- -40°C To 105°C
- Stationary min. bend radius
- 3.2 in (81 mm)
- Max. pull tension
- 995.7 lbs (451.6 kg)
7129W Applications
- Robotics
- Robot
- Continuous Flex
Other Belden parts
- 29511 — Belden 29511 is a flexible 600 V/1000 V motor supply cable built for variable fr...
- 45198 — The Belden 45198 is an XTRAGUARD 4 cable with 8 conductors of 22 AWG (7/30) tinn...
- 50960 — Belden 50960 is a security and commercial audio cable with four 2.5 mm² stranded...
- 9923 — The Belden 9923 is a low-temperature plastic lead wire featuring a 24 AWG tinned...
- 78321 — The part 78321 is a 15-conductor, 26 AWG tinned copper cable with modified polyp...
- 21606 — Belden 21606 is a CSA Type TC-CIC 600 V tray cable with eight 10 AWG bare copper...
- 78014 — The 78014 is a 4-conductor 26 AWG tinned copper cable with modified polyphenylen...
- 80008 — The Belden 80008 is an ECOFLEX PUR 2-conductor 24 AWG cable featuring tinned cop...
More Bulk Wire Cable
- 8790 — The Belden 8790 is a line level audio cable designed for low voltage analog sign...
- 48643AZ — The Belden 48643AZ is a UL Type TC power and control cable rated up to 600 V. It...
- 5584C — The Belden 5584C is an XTRAGUARD 1 shielded multi-conductor cable featuring 19 c...
- 37504 — Belden 37504 is a rubber lead wire built with a 4 AWG (105x24) tinned copper con...
- 1761 — The Belden 1761 is a 3-conductor, 12 AWG tinned copper control and communication...
- 3410 — The Belden 3410 is a 10-conductor, 18 AWG tinned copper control cable with PVC i...
- 86702CY — The 86702CY is an XTRAGUARD FLEX continuous flex data cable consisting of 2 pair...
- 23533D — The Belden 23533D is a 300 V TC-ACIC instrumentation cable with one 18 AWG (7x26...
7129W FAQ
What is 7129W?
7129W is a Bulk Wire Cable from Belden. The Belden 7129W is a MachFlex™ high-flex multi-conductor cable designed for continuous flexing applications such as robotics. It features 24 bare copper conductors plus one ground wire, all insulated with PVC/Nylon and enclosed in a TPE outer jacket. The cable is rated for 1000 V WTTC and 600 V TC-ER, offering excellent resistance to outdoor elements, sunlight, UV, and oil.
Who manufactures 7129W?
7129W is manufactured by Belden.
Where can I download the 7129W datasheet PDF?
The 7129W datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 7129W specifications
Click to ask a quick question:
Parameters
| Conductor configuration | 24+1 Conductor 16AWG (168(7x24) x38) Bare Copper |
| Conductor resistance (DCR) | 4.18 Ohm/1000ft (conductor), 4.45 Ohm/1000ft (ground wire) |
| Max. current per conductor | 11.4 Amps per conductor at 30°C (conductor), 30.4 Amps per conductor at 30°C (ground wire) |
| Max. pull tension | 995.7 lbs (451.6 kg) |
| Operating temperature | -40°C To 105°C |
| Overall cable diameter (nominal) | 0.8 in |
| Stationary min. bend radius | 3.2 in (81 mm) |
| Voltage rating | 1000 V (WTTC), 600 V (TC-ER) |