6192 Datasheet
The Belden 6192 is a Teck90 1000V heavy-duty cable featuring two 6 AWG bare copper conductors and an 8 AWG bare copper ground wire, with XLPE insulation, a black PVC inner jacket, steel interlock armor, and a black PVC outer jacket. It is designed for CEC power and control applications in indoor and outdoor environments, resisting sunlight and UV exposure. The cable operates within a temperature range of -40°C to +90°C and supports a maximum current of 75 Amps per conductor at 30°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
6192 Key Specifications
- Max. Current per Conductor
- 75 Amps per Conductor at 30ºC
- Voltage Rating
- 1000 V (TECK 90)
- Operating Temperature
- -40°C To +90°C
- Bulk Cable Weight
- 753 lbs/1000ft
- Conductor Configuration
- 2 conductors of 6 AWG 7x14 bare copper, 1 ground wire of 8 AWG 7x16 bare copper
- Max. Pull Tension
- 1114.2 lbs (505.39 kg)
- Nom. Conductor DCR
- 0.411 Ohm/1000ft (Conductor), 0.667 Ohm/1000ft (Ground Wire)
- Overall Cable Diameter (Nominal)
- 1.047 in
Characteristics (datasheet)
- Voltage Rating
- 1000 V (TECK 90)
- Conductor Configuration
- 2 conductors of 6 AWG 7x14 bare copper, 1 ground wire of 8 AWG 7x16 bare copper
- Max. Current per Conductor
- 75 Amps per Conductor at 30ºC
- Nom. Conductor DCR
- 0.411 Ohm/1000ft (Conductor), 0.667 Ohm/1000ft (Ground Wire)
- Operating Temperature
- -40°C To +90°C
- Overall Cable Diameter (Nominal)
- 1.047 in
- Max. Pull Tension
- 1114.2 lbs (505.39 kg)
- Bulk Cable Weight
- 753 lbs/1000ft
6192 Applications
- CEC Power and Control Applications
Other Belden parts
- 5680 — The Belden 5680 is a 10-conductor, 26 AWG tinned copper cable with semi-rigid PV...
- 9450 — The Belden 9450 is a single-conductor coaxial cable with a 50 AWG silver-coated...
- 3252 — The Belden 3252 is a single-conductor, 20 AWG tinned copper hook-up wire with se...
- 21662 — Belden part 21662 is a CSA Type TC-CIC tray cable rated 600 V, built with two 2...
- 86202 — The Belden 86202 is a 2-conductor, 24 AWG tinned copper cable with semi-rigid PV...
- 28141A — The Belden 28141A is a UL Type TC power and control cable with five 10 AWG bare...
- 8167 — The Belden 8167 is a computer EIA RS-232/422 digital audio cable containing 7 in...
- 6711 — The Belden 6711 is a single-conductor hook-up wire featuring a 26 AWG stranded t...
More Bulk Wire Cable
- 8332 — The Belden 8332 is a computer EIA RS-232 cable designed for extended distance ap...
- 5314C — The Belden 5314C is a 19-conductor, 22 AWG shielded cable with semi-rigid PVC in...
- 76021 — The Belden 76021 is an industrial Ethernet Category 5e cable consisting of 4 pai...
- 29036 — The Belden 29036 is a TC-ACIC Canadian instrumentation cable rated for 600 V, wi...
- 79005 — ECOFLEX part 79005 is a 7-conductor 20 AWG tinned copper cable with mPPE insulat...
- 6049 — The Belden 6049 is a Teck90 600V cable featuring 50 bare copper conductors plus...
- 83028 — The Belden 83028 is a high-temperature plastic lead wire featuring a 20 AWG silv...
- 8816 — The Belden 8816 is a low-temperature plastic lead wire kit on racks, consisting...
6192 FAQ
What is 6192?
6192 is a Bulk Wire Cable from Belden. The Belden 6192 is a Teck90 1000V heavy-duty cable featuring two 6 AWG bare copper conductors and an 8 AWG bare copper ground wire, with XLPE insulation, a black PVC inner jacket, steel interlock armor, and a black PVC outer jacket. It is designed for CEC power and control applications in indoor and outdoor environments, resisting sunlight and UV exposure. The cable operates within a temperature range of -40°C to +90°C and supports a maximum current of 75 Amps per conductor at 30°C.
Who manufactures 6192?
6192 is manufactured by Belden.
Where can I download the 6192 datasheet PDF?
The 6192 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 6192 specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 753 lbs/1000ft |
| Conductor Configuration | 2 conductors of 6 AWG 7x14 bare copper, 1 ground wire of 8 AWG 7x16 bare copper |
| Max. Current per Conductor | 75 Amps per Conductor at 30ºC |
| Max. Pull Tension | 1114.2 lbs (505.39 kg) |
| Nom. Conductor DCR | 0.411 Ohm/1000ft (Conductor), 0.667 Ohm/1000ft (Ground Wire) |
| Operating Temperature | -40°C To +90°C |
| Overall Cable Diameter (Nominal) | 1.047 in |
| Voltage Rating | 1000 V (TECK 90) |